background image

Summary of Contents for MZ-80FB

Page 1: ...INSTRUCTION MANUAL ...

Page 2: ...res in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured BLU E must be connected to the terminal which is marked with the letter N or coloured BLACK The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED ...

Page 3: ...l be very useful as an external memory unit because of its large capacity and high speed access Read this instruction manual carefully before using the Floppy Disk so you can use it correctly Page Floppy Disk MZ 80FB 2 Connecting the MZ 80B and MZ 80FB 3 Extension Floppy Disk MZ 80FBK 4 Connecting the Extension Floppy Disk 5 Floppy Disk Operation 6 Handling the Diskette 7 Cautions 8 Specifications...

Page 4: ...ON 7 Signal Terminal Connect the connector of the signal cable option to this terminal S Power Switch Push this switch toward I to turn on the power 9 Appliance Inlet Connect the supplied power cord here 10 FG Terminal Connect the supplied braided wire to this terminal 11 Rating Name Plate Use a power supply with the voltage shown here 12 Braided Wire Accessory Connect this wire to the FG terminal...

Page 5: ...ce the screws 2 Connect the connector of signal cable MZ 80FC to the signal terminal of the I O card Either the right or left cable connector can be used 3 With the supplied screws firmly fix the right and left sides of the connector to fasten it as shown on the left Do not forget to put in these screws Fasten screws in two places 4 Connect the connector on the other end of the signal cable to the...

Page 6: ...0FC here ID Signal Terminal OUT Connect signal cable MZ 80FCK here 1 Power Switch Push this switch toward I to turn on the power j Appliance Inlet Connect the supplied power cord here 11 FG Terminal Connect the supplied braided wire to this terminal 1 Rating Name Plate Use a power source with the voltage shown here L Braided Wire Accessory Connect this wire to the FG terminal using it to connect t...

Page 7: ...same as that on page 3 section 2 and 3 Fasten screws in two places 3 First connect signal cable MZ 80FCK to the signal terminal of the MZ 80FB Use either cabie connector Then in the same way as mentioned above firmly fix both sides of the connector with the suppl ied screws to fasten it Fasten screws in two places 4 Connect the connector on the other end of signal cable MZ 80FCK to the right side ...

Page 8: ...the front door will not close When this happens do not force the door closed but re insert the diskette correctly 3 Write protection Notch If the write protection notch of the diskette is covered with a seal of silver paper etc writing of data is forbidden Reading however is possible Some diskettes supplied by Sharp that are called Masters have this part covered with a seal Never remove it because...

Page 9: ...te near machines motors etc that generate a magnetic field Fill in the index label before pasting it on the jacket or use a soft pointed pen If you use a ball point pen or other hard object on a label already pasted on the jacket the diskette will be damaged When not using a diskette put it in an envelope and file it away This also prevents trouble caused by scratches and dust Storage temperature ...

Page 10: ...rate power source for these kinds of machines This will prevent improper operation due to noise 5 Do not close the ventilation holes of the unit by putting things on top of it or by covering it with a cloth etc 6 Use only the supplied power cord 8 Operation 1 Do not use the unit in ways not written in the instruction manual 2 When operating this unit be sure that all signal cable and other connect...

Page 11: ...0 K byte sheet at 16 sectors track Local supply voltage Use power supply voltage as shown on rating name plate 40W for AC 220V 50Hz unit 45W for AC 240V 50Hz unit 4 C 25 C 20 80 Free of moisture 205 W x 320 D x 200 H mm 7 9kg Power cord 1 Braided wire 1 Instruction manual 1 Signal cable MZ 80FC for MZ 80FB Signal cable MZ 80FCK for MZ 80FBK I O card MZ 80FI for floppy disk Specifications and desig...

Page 12: ... SHARP CORPORATION TI NSE0016PAZZ 801205 1000 K Pri nted in Japan MZ 80FB FBK E1 ...