background image

1

E

E

SPECIAL WARNING

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE THIS INSTALLATION MANUAL FOR LOCAL ELECTRICAL INSPECTOR’S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Radiant Cooktop: SCR3042FB, SCR3041GB, SCR2442FB

INSTALLATION MANUAL

IMPORTANT NOTES TO THE INSTALLER

•  Read all of the Installation Manual before installing the Radiant 

Cooktop.

•  Remove all packing material before connecting the electrical 

supply.

•  Observe all governing codes and ordinances.
•  Be sure to leave these instructions with the consumer.
•  All cooktops must be hard wired (direct wired) into an approved 

junction box.  A “plug and receptacle” is not permitted on these 

products.

IMPORTANT SAFETY INSTRUCTIONS

 If the information in this manual is not followed 

exactly, a fire or electrical shock may result that could cause 

property damage, personal injury or death.

 Never leave children alone or unattended in 

the area where a cooktop is in use.

 Stepping, leaning or sitting on the cooktop 

may result in serious injuries and can also cause damage to 

the cooktop.

•  For Your Safety: Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other appliance. 

To eliminate the risk of burns or fire due to overheating, cabinets 

located above the radiant unit should be avoided. If cabinet space 

is available, the risk can be reduced by installing a range hood 

that protects horizontally at a minimum of 5 inches below the 

bottom of the cabinets

•  To prevent accidents and achieve optimal ventilation, allow for 

sufficient space around the cooking area. 

IMPORTANT INSTALLATION INFORMATION

•  Dimension

s that are shown in Figures 3 & 7 must be used. Given 

dimensions provide minimum clearance.

•  Contact surface must be solid and level.
•  Check location where the cooktop will be installed for proper 

electrical supply.  Approximate location of junction box, min 12" 

(304.8 mm) below the cooktop.  See Figure 4.

•  Your cooktop can be installed into a countertop by itself, above 

a gas or electric wall oven, above a microwave drawer, or above 

a convection microwave drawer.

•  All electric cooktops run off a single phase, three-wire cable, 

240V/60Hz AC only electrical supply with ground. Minimum 

distance between cooktop and overhead cabinetry is 3

0".

PART INCLUDED

PARTS 

QTY.

Cushion Tape # PCUSGB125MRP0

770 mm x 6 mm x 2 mm

2

Cushion Tape # PCUSGB126MRP0

540 mm x 6 mm x 2 mm

2

BEFORE INSTALLING THE COOKTOP

 

1. Visually inspect the cooktop for damage.  Also make sure all 

cooktop screws are on tight.

2. Record the model and serial number as found on the bottom of 

your cooktop. When ordering parts for or making inquiries about 

your cooktop, always be sure to include the model and serial 

numbers and a lot number or letter from the serial plate on your 

cooktop.

3.  Prepare the cutout dimensions of the countertop.
4. Make sure the wall coverings, countertop and cabinets around 

the cooktop can withstand heat (up to 200°F) generated by the 

cooktop.

5. Apply the included cushion tape around the outer edge of the 

glass on all four sides.  Do not overlap the tape.  See Figure 1.

6.  Gently lower the cooktop into the countertop cutout.
NOTE: Do not seal the cooktop to the countertop, the cooktop must 

be removable if service is necessary.

Bottom of Cooktop

Foam Tape

Cooktop 

Glass

Figure 1

1

Summary of Contents for SCR2442FB

Page 1: ...n allow for sufficient space around the cooking area IMPORTANT INSTALLATION INFORMATION Dimensions that are shown in Figures 3 7 must be used Given dimensions provide minimum clearance Contact surface must be solid and level Check location where the cooktop will be installed for proper electrical supply Approximate location of junction box min 12 304 8 mm below the cooktop See Figure 4 Your cookto...

Page 2: ...A and wire should be 2 8 or 3 8 copper 4 Minimum acceptable size of conductors should be no less than 10AWG copper only and no less than 167 F 5 A wire binding screw or stud used in the wire terminal should be 10 or larger The electrical power to the cooktop must be shut off while line connections are being made Failure to do so could result in serious injury or death An extension cord must not be...

Page 3: ...0 mm C 30 762 mm min to unprotected wood D 18 457 mm E 28 5 8 727 mm F 19 11 16 500 mm G 4 1 2 114 mm H Minimum 2 51 mm I Minimum 2 51 mm Figure 4 Figure 5 Figure 6 COOKTOP AND CUTOUT DIMENSIONS See Figure 4 COOKTOP CUTOUT OPENING DIMENSIONS See Figure 5 H A D B E C G F I 30 76 2 cm min for cabinet Do not obstruct these areas CAUTION It is very important to keep 21 2 63 5 mm distance between the c...

Page 4: ...C 30 762 mm min to unprotected wood D 18 457 mm E 22 3 8 568 mm F 19 11 16 500 mm G 4 1 2 min 114 mm H Minimum 2 51 mm I Minimum 2 51 mm Figure 7 Figure 8 COOKTOP AND CUTOUT DIMENSIONS See Figure 7 COOKTOP CUTOUT OPENING DIMENSIONS See Figure 8 A B D E G F C H I Approximate location of junction box min 12 304 8 mm below cooktop H A D B E C G F I 30 76 2 cm min for cabinet Do not obstruct these are...

Page 5: ...eration manual 4 Turn on the power to the cooktop 5 Verify all functions operate properly NOTE If the cooktop does not work or you find any problem in its operation please check that the circuit breaker has not tripped or a fuse has not blown For more information please See Before You Call for Service in the operation manual If you do not solve the problem by yourself please please contact us at 1...

Page 6: ...SHARP ELECTRONICS CORPORATION 100 Paragon Drive Montvale New Jersey 07645 USA SHARP ELECTRONICS OF CANADA LTD 335 Britannia Road East Mississauga Ontario L4Z 1W9 Canada ...

Page 7: ...T ÊTRE EFFECTUÉS PAR UN INSTALLATEUR QUALIFIÉ IMPORTANT VEUILLEZ CONSERVER CE MANUEL D INSTALL ATION POUR L A VÉRIFICATION DE L INSPECTEUR EN ÉLECTRICITÉ VEUILLEZ LIRE ET CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCE ULTÉRIEURE La surface de contact doit être solide et plane Vérifier que l emplacement où la surface de cuisson sera installée dispose de l alimentation électrique appropriée Emplacement a...

Page 8: ...m acceptable des conducteurs doit être d au moins 10 AWG en cuivre seulement et supérieur à 167 F 75 C 5 La vis ou le plot de contact utilisé dans le terminal doit être de 10 ou plus gros AVERTISSEMENT L alimentation électrique de la surface de cuisson doit être coupée lors du branchement des lignes Ne pas respecter cette consigne peut entraîner des blessures graves ou la mort Une rallonge électri...

Page 9: ...FACE DE CUISSON ET DE LA DÉCOUPE voir la figure 4 DIMENSIONS DE L OUVERTURE DE LA DÉCOUPE POUR LA SURFACE DE CUISSON voir la figure 5 63 5 mm 2 1 2 po FOUR MISE EN GARDE Il est très important de garder un espace de 63 5 mm 21 2 po entre la surface de cuisson et le four Remarque Un séparateur est nécessaire entre le four et la table de cuisson H A D B E C G F I 30 76 2 cm min for cabinet Do not obs...

Page 10: ...m 2 po A 610 mm 24 po B 330 mm 13 po C 762 mm 30 po jusqu au bois non protégé D 457 mm 18 po E 568 mm 22 3 8 po F 500 mm 19 11 16 po G 114 mm 4 1 2 po H Minimum 51 mm 2 po I Minimum 51 mm 2 po Figure 7 Figure 8 DIMENSIONS DE LA SURFACE DE CUISSON ET DE LA DÉCOUPE voir la figure 7 DIMENSIONS DE L OUVERTURE DE LA DÉCOUPE POUR LA SURFACE DE CUISSON voir la figure 8 A B D E G F C H I Approximate locat...

Page 11: ...nuel d utilisation 4 Mettez la surface de cuisson sous tension 5 Vérifiez pour vous assurer que tout fonctionne correctement REMARQUE Si la surface de cuisson ne fonctionne pas ou si vous trouvez des problèmes dans son fonctionnement veuillez vous assurer que le disjoncteur ne s est pas déclenché ou qu un fusible n a pas sauté Pour plus de renseignements veuillez consulter la rubrique Avant de com...

Page 12: ...SHARP ÉLECTRONIQUE DU CANADA LTÉE 335 rue Britannia Est Mississauga Ontario L4Z 1W9 Canada Dec 17 2020 TINSEB583MRR0 ...

Reviews: