OPERATION MANUAL
CAUTION:
•
Potential hazard of glass particles if the lamp ruptures. Please have the nearest Authorized SharpVision Service Center or Dealer (for XV-Z9000U) or Sharp Authorized Projector Dealer or Service
Center (for XV-Z9000E) replace the lamp if rupture occurs.
•
Do not remove the lamp cage directly after operation of the projector. The lamp may be extremely hot. Wait at least one hour after the power cord is disconnected to allow the surface of the lamp cage to
fully cool before removing the lamp cage.
It is recommended that the lamp be replaced after approximately 1,900 cumulative hours of use or when you notice a significant deterioration of the picture and color quality. Carefully change the lamp by following the steps
below.
If the new lamp does not light after replacement, take your projector to the nearest Authorized SharpVision Service Center or Dealer (for XV-Z9000U) or Sharp Authorized Projector Dealer or Service Center (for XV-Z9000E)
for repair.
IMPORTANT NOTE TO U.S. CUSTOMERS:
The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of this projector under warranty, including lamp replacement, must be obtained through the nearest Authorized SharpVision
Service Center or Dealer. For the name of the nearest Authorized SharpVision Service Center or Dealer, please call toll-free: 1-877-DTV-SHARP (1-877-388-7427).
Removing and installing the lamp unit
1
3
Turn off the power.
2
Remove the lamp cage cover.
4
Remove the lamp cage.
6
5
7
8
• You need to reset lamp timer every time when replacing the lamp and confirm it to be reset on “Lamp Timer” menu.
LAMP UNIT (LAMP/CAGE MODULE) FOR PROJECTOR
BQC-XVZ9000/1
Part No.
U.S.A. ONLY
Printed in Japan
TINS-7473CEZZ
• Be sure to remove the lamp cage by the handle. Do not touch the glass surface of the lamp cage or the inside of the projector.
• To avoid injury to yourself and damage to the lamp, carefully follow the steps below.
• Replace the lamp after turning off the power and unplugging the power cord.
Press
POWER OFF
. Wait until the
cooling fan stops running.
Unplug the power cord.
Loosen the user service screw that
secures the lamp cage cover on the side
of the projector. Then lower the cover in
the direction of the arrow (to the open
mark).
User service screws
Remove the three-securing
screws from the lamp cage. Hold
the lamp cage by the handle and
pull it horizontally towards you.
Insert the new lamp cage.
Press the lamp cage firmly into the
lamp cage compartment.
Fasten the three-securing screws.
Attach the lamp cage cover.
Close the lamp cage cover in the
direction of the arrow (to the close
mark) on the side of the projector.
Then tighten the user service screw.
1
2
Plug in the power cord.
While holding down
ENTER
,
"
and
|
, press
POWER ON
.
Press POWER ON on projector to reset lamp timer.
User service screws
“LAMP 0000H” is
displayed, indicating
that the lamp timer is
reset.
CAUTION
BQC_XVZ9000_1.eps
04.5.28, 10:36 AM
1