background image

1

TZ-RD01

TAG06

V1.7

---User Manual

Summary of Contents for TZ-RD01

Page 1: ...1 TZ RD01 TAG06 V1 7 User Manual ...

Page 2: ...d stability and high speed data processing capabilities and can support a variety of data formats repeated reading technology dynamic key encryption and authentication to ensure data security prevent eavesdropping and crack data link 2 Key Functions External special USB configure interface user can configure RD01 operating module Prevent collision advanced technology to prevent the collision can i...

Page 3: ...5 non condensing IP level IP55 Dimension 78mm 66mm 26mm Extra interfaces Interface Instructions USB Use specially designed USB cable connect to PC RS232 Output the data For communications and other equipment POWER DC9 24V ...

Page 4: ...status 1 Temperature more than set high and low temperature threshold 0 Temperature normal bit5 bit0 reserved Battery voltage 2 byte Unit 1mv 0C 50 means voltage is 3 152V The first bit of temperature means normal abnormal 0 normal 1 abnormal The second bit of temperature means positive negative 0 positive 1 negative After the third bit of temperature means real temperature unit 0 1 For example 01...

Page 5: ...gested you can get it from the website There is the vision of PL2303 driver checking way Device manager Ports COM LPT choose your COM right hand button Update Driver Software Browse my computer for driver software pick from a list from device drivers choose 2009 version As shown in figure 5 3 I have chosen the version 2009 Figure 5 1 PL2303 driver installing ...

Page 6: ...6 Figure 5 2 PL2303 Checking driver Figure 5 3 PL2303 choose version 2009 7 17 ...

Page 7: ...1 parity None flow control None and then click open the serial port Note if users to set the parameters of RS232 please also set the response parameters in sscom32 5 4 ASCII commands to configure RD01 After completing the above steps to RD01 on electricity then send the FFF make machines to enter configuration mode according to the instruction table 5 1 set up machine set up after the completion o...

Page 8: ...II 11 RS232 setting 11 A B C D A baud 600 128000 115200 default B digital bits 0 8bit default 1 9bit C stop bits 0 0 5bit 1 1bit default 2 1 5bit 3 2bit D parity bits 0 none default 1 Even 2 Odd 13 RS232 data mode setting 13 X X 0 active mode default 1 Passive mode About passive mode need upper computer send command to read data Reading command is AA ID of RD01 03 HEX For example AA123403 HEX Quer...

Page 9: ...from the website 1 As Figure 1 1 is the main board of Hypertrm exe 2 Figure 1 2 do file new connection to create n new connection 3 Figure 1 3 choose the COM you have used mine is COM3 4 Figure 1 4 do as the figure shown 5 And then File Save to save the new connection 6 Next time File Open can open the connection 7 Hold the DFU then connect the power supply LED lights have been on 8 Click keyboard...

Page 10: ...10 Figure 1 1 main board Figure 1 2 create a new connection ...

Page 11: ...11 Figure 1 3 choose the COM that has been used Figure 1 4 configure parameter ...

Page 12: ...12 Figure 1 5 waiting for updating Figure 1 6 choose the right firmware ...