"Notice"

Please ensure that this instruction manual is made accessible to the 
final user of this instrument. 

Preface

This instruction manual is provided for those who will be involved in 
the wiring, installation, operation and routine maintenance of the 
SR80 series (SR82, SR83 and SR84).  This manual describes the care, 
installation, wiring, function and operating procedure of the SR80 
series.  Keep this manual at the work site during operation of the 
SR80 series. While using this instrument, you should always follow 
the guidance provided herein. 

For matters concerning safety, potential damage to equipment and/or 
facilities, additional instructions and notes are indicated by the 
following headings: 

Indicates matters which may result in accidents leading to injury or 
death if proper attention is neglected. 

·

 WARNING 

Indicates matters which may result in damage to equipment and/or 
facilities. 

·

 CAUTION 

Indicates that additional instructions and notes have been provided. 

NOTE
The mark

Ã

 

represents a protective conductor terminal. 

Ensure that it is grounded properly. 

Matters to be attended to for safety's sake:

·

CAUTION

In the event a potential failure of the instrument could cause 
damage to the connected equipment, facilities or products, safety 
measures such as installing a fuse or an overheating protection 
device must be taken prior to the use of the instrument.  We 
assume no responsibility for any accident which may occur as a 
result of not employing appropriate safety measures 

·

CAUTION

• The 

·

mark on the plate affixed to the instrument: On the terminal 

nameplate affixed to the case of the instrument, the 

·

mark has 

been printed.  This is to warn you of the risk of electric shock 
which may result if the charger is touched while it is energized. 

• In the external power circuit to be connected to the power terminal 

of the instrument, a switch or a breaker as means to turn power off 
must be installed.  Such a switch or a breaker should be fixed 
adjacently to the instrument so that it can be operated with ease, 
and with an indication that it is a means to turn power off. Use a 
switch or a breaker which meets the requirements of IEC60947. 

• Fuse: Since the instrument does not have a built-in fuse, make sure 

to install a fuse in the power circuit to be connected to the power 
terminal.  The fuse should be positioned between the switch or the 
breaker and the instrument and be attached to the L side of the 
power terminal. 
Fuse rating/type: 250V AC 0.5 A/medium lagged or lagged type. 
Use a fuse which meets IEC60127 requirements. 

• In the wiring operation, make sure to fasten terminal connections. 
• Power voltage and frequency must be within their rated ranges. 
• Voltage/current of a load to be connected to the output terminal 

and the alarm terminal should be within a rated range.  If it goes 
out of the range, a rise in temperature will reduce the product life 
and/or result in problems with the product. 
The output terminal should be connected with a device which 
meets IEC61010 requirements. 

• Voltage/current out of its specified range should not be applied to 

the input terminal.  It may reduce the product life and/or result in 
problems with the product. 
For the rated voltage/current, refer to "7. Specifications." 
In case input is of voltage (mV or V) or current (4-20 mA), the 
input terminal should be connected with a device which meets 
IEC61010 requirements. 

• The SR80 series controller is provided with a draft hole. 

Take care to prevent metal or other foreign matter from entering 
into it.  Failure to do so may cause problems with the instrument or 
even fire 

• Do not block the draft hole and maintain it free from dust and dirt.  

A rise in temperature or insulation failure may result in a 
shortening of the product life and/or problems with the instrument.  
For spaces required to be kept in its installation, see "2-3. 
Drawings showing external dimensions and panel cutout." 

• It should be noted that repeated tolerance tests against voltage, 

noise, surge, etc. may lead to deterioration of the instrument. 

• Users are prohibited from modifying the instrument and using it in 

an anomalous way. 

• When employing the instrument, you are requested to observe 

matters to be attended to as described in the instruction manual 
concerning safe and correct operation of the instrument in order to 
use it safely while maintaining its reliability 

·

WARNING

The SR80 series controllers are control instruments designed for 
industrial use to control temperature, humidity and other physical 
values. You must not employ this series for the control of any 
device potentially having a serious effect on human life without 
employing adequate and effective safety measures. We assume no 
responsibility for any accident arising from the use of this product 
without first taking effective safety measures. 

·

WARNING

• The instrument should be installed, for example, in a control 

panel to prevent its terminal portion from accidental contact with 
a human body during its operation. 

• The instrument should not be pulled out from its case.  Never 

place your hand or an electric conductor inside it as such act may 
cause an electric shock resulting in serious injury or death. 

• Make sure to ground the protective conductor (earth) terminal 

prior to using the instrument. 

Note

:

It takes 30 minutes to display the correct temperature after 

applying power to the digital controller. (Therefore, turn the 
power on more than 30 minutes prior to the operation.) 

SR80 Series 

(SR82 / SR83 / SR84) 

Digital Controller 

Instruction Manual 

Thank you for purchasing the Shimaden SR80 series digital controller. 
Please check that the delivered product is the correct item you ordered. Please do not begin operating this product until 
you have read this instruction manual thoroughly and understand its contents. 

SR80F-1IE

July 2019

Summary of Contents for SR80 Series

Page 1: ...f it goes out of the range a rise in temperature will reduce the product life and or result in problems with the product The output terminal should be connected with a device which meets IEC61010 requ...

Page 2: ...k alarm 50A 1 Remote input 2 00 None 14 4 20mA DC Not insulated 15 1 5V DC Not insulated 16 0 10V DC Not insulated Analog output 3 0 None 3 0 10mV DC 4 4 20mA DC 6 0 10V DC Communication 3 0 None 5 RS...

Page 3: ...high voltage power lines 6 Shield wiring one point grounding works effectively against static induction noise 7 Twisting the input signal wire at equal intervals is effective against electromagnetic i...

Page 4: ...ransformer CT Pass one load wire through the hole specifically provided or CT CT terminals on the secondary side are wired to the CT input terminal of the SR80 controller 1 SR82 2 SR83 1 Output 2 Outp...

Page 5: ...y parameter screen the mode 0 basic screen returns onto the display 2 parameter key When pressed on any of the mode 0 and 1 screen groups the next screen appears When this key is pressed continuously...

Page 6: ...digit digit digit digit digit digit...

Page 7: ...0 32 screens are the same as the other PID parameters Initial value 2 0 digit Setting range 1 1000 digit digit Initial value 2 0 digit Setting range 1 1000 digit Initial value 2 0 digit Setting range...

Page 8: ...digit digit It is conditional that rE_L rE_H It is conditional that rE_L rE_H...

Page 9: ......

Page 10: ...s effect when DI input turns ON When to detect external control input signal Level input The action is maintained as long as the contact remains ON Edge input The action is maintained even when the co...

Page 11: ...key for confirmation The AT lamp goes out Note When AT is cancelled in the mid operation PID values remain unchanged AT is automatically cancelled under the following conditions 1 Output value remains...

Page 12: ...STBY EXE 3 SV is changed where standby set value is a deviation value Except during remote input though When the standby action setting is changed to oFF or 4 while standby is in action the standby a...

Page 13: ...lamp display Control output OUT1 2 green Event action EV1 2 3 orange Auto tuning action AT green Manual control action MAN green Set value bias action SV2 SB green Remote action REM green Standby acti...

Page 14: ...ual switching Front key operation or DI external switching input through communication Manual control output 0 0 100 0 out of output limiter range possible Setting resolution 0 1 Manual automatic cont...

Page 15: ...1 RS 232C RS 485 Communication system RS 232C 3 line half duplex system RS 485 2 line half duplex multiple drop bus system Synchronization system Start stop synchronization system Communication distan...

Page 16: ...tween input output terminals and power terminal 500V DC 20M minimum Between input output terminals and protective conductor terminal 500V DC 20M minimum Dielectric strength 1 minute at 3000V AC betwee...

Reviews: