background image

20

 

40

 

500 

80 

3000 

3-1.25-YASS3.5 

USB plug 

75 

40

 

500 

80 

3000 

3-AI0.25-8YE 

75 

Instruction Manual 

USB COMMUNICATION CABLE   

CMC-001

 

No. CMCJE4  2021.05 

This manual contains instructions for functions and usage of the USB 
communication cable (CMC-001). To ensure safe and correct use, thoroughly read 
and understand this manual before using this cable. To prevent accidents arising 
from the misuse of this cable, please ensure the operator receives this manual. 

 

Safety Precautions

 

 

 

Caution 

 

 

 

 

 

Safety Precautions

 

(

1) Do not confuse the direction of the USB plug when connecting this 

  cable to the USB port. If the plug cannot be inserted smoothly, do not force 
  it to enter. This may damage the plug or port.   

(2) Do not bend or pull forcibly or put any heavy object on the cable. 
(3) Do not connect or remove this cable during communication.   

This may cause damage or malfunction.   

(4) Do not allow the metallic section of this cable to come into contact with 

external power terminals. 

(5) Do not handle the cable plug with wet hands. This may result in electric shock. 

Precautions 

 

Caution

 

(1) Ensure the cable is used under the following conditions: 

• A minimum of dust, and an absence of corrosive gases 
• No flammable, explosive gases 
• No mechanical vibrations or shocks 
• No exposure to direct sunlight, an ambient temperature of 0 to 50   (32 to 

122 ) that does not change rapidly, and no icing 

• An ambient non-condensing humidity of 35 to 85%RH 
• No large capacity electromagnetic switches or cables through which large 
  current is flowing 
• No water, oil, chemicals or where the vapors of these substances can 

come into direct contact with the cable 

• Ambient temperature of this cable must not exceed 50   (122 ) if mounted 

within the control panel. 

(2) It sometimes takes time for the PC to identify the cable when the USB 
  plug of this cable is connected to the PC. However, this is not a malfunction. 
  Be sure to confirm the COM port number before starting communication. 
(3) Do not extend this cable using an extension cable when connecting to the 
  PC. A malfunction may occur. 
(4) Use a soft, dry cloth when cleaning this cable. 

(Alcohol based substances may deface or tarnish the cable.)

 

1. Model 

1.1

 

Model 

CMC-001 

-

   

Controller side   
connector 

  1  Y-type terminal 
  2  Ferrules 
  3  Modular connector RJ-11 
  4  Modular connector RJ-45 

 

1.2 How to Read the Model Label   

The model label is attached to the case. 

 
 

 

 

 

 

 

(Fig. 1.2-1) 

2. Plug Types and Dimensions 

(Scale: mm)

 

CMC-001-1 

 

 
 
 
 
 
 
 

 

(Fig. 2-1) 

CMC-001-2 
 
 
 
 
 
 

 

(Fig. 2-2) 

CMC-001-3 
 
 
 
 
 
 

 

(Fig. 2-3) 

CMC-001-4 
 
 
 
 
 
 

 

(Fig. 2-4) 

 

3. Pin Arrangement

 

  CMC-001-3 

CMC-001-4 

Pin No. 

 

 

Pin No. 

 

COM 

 

 

COM 

YB(+) 

 

YA(-) 

 

YA(-) 

 

YB(+) 

COM 

 

 

 

 

COM 

 

 

 

 

4. Usage 

(1) Turn the power supply to the PC ON, and start Windows

(2) Connect the cable. 

Check that the power supply to the instrument is turned OFF. 
Connect the USB port of the PC to the instrument, using this cable. 

  Connection example of CMC-001-1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

(Fig. 3-1)

 

Model   

Cable length 

Serial number 

Indicates procedures which may lead to 

dangerous conditions and cause superficial to 

medium injury or physical damage or may degrade 

or damage the product, if not carried out properly. 

(Be sure to read these precautions before  

using this cable.)

 

40

 

500 

80 

3000 

Modular connector TM20P-66P 

40

 

500 

80 

3000 

Modular connector RJ-45 

USB communication cable 

CMC-001-1 (Sold separately) 

YA(-) 
YB(+) 
COM 

16 YA(-) 
17 YB(+) 
18 SG 

16 YA(-) 
17 YB(+) 
18 SG 

16 YA(-) 
17 YB(+) 
18 SG 

Shielded wire 

Shielded wire 

Host computer 

USB port 

BCS2 

(Max. 31 units

 

和文は裏面をご覧ください。

 