background image

 
 

 

        TriFlood 

 

 

 

 

 

            

ORDERCODE 50464 

 

 
 

Summary of Contents for TriFlood

Page 1: ...TriFlood ORDERCODE 50464 ...

Page 2: ... Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec info You can get some of the best quality best priced products on the market from Showtec So next time turn to Showtec for more great lighting ...

Page 3: ...ions Description Features and Overview Backside Installation Installing the Lamp Set Up and Operation One TriFlood Multiple TriFloods DMX Protocol Control Modes Stand alone mode Sound Control mode DMX mode Control Panel DMX Channels Maintenance Changing the Lamp Replacing the Fuse Troubleshooting No Light No Response to DMX Product Specifications ...

Page 4: ... cover is open as discharge lamps may expose and emit a high ultraviolet radiation which may cause burns Do not open the device and do not modify the device Never look directly into the light source Never leave any cables lying around Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch the device on and off in short intervals as this would reduce the lamp ...

Page 5: ...by the misuse or incorrect installation of this device This device falls under protection class I Therefore it is essential to connect the yellow green conductor to earth During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Repairs servicing and electric connection must be carried out by a qualified technician...

Page 6: ... 512 3 DMX modes 2 3 or 4 channels depending on the Control Modi Stand Alone Sound activated Automatic Auto sound master slave mode 16 built in programs Color R G B Lamp 300W 3pcs Lamp 3x R7 S 300W ordercode 82281 NOTE Knowledge of DMX is required to fully utilize this unit Overview Fig 1 1 Mounting bracket 2 Fixation screw ...

Page 7: ... Always disconnect from electric mains power supply before changing lamps The lamp has to be replaced when it is damaged or deformed due to the heat Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the 4 screws on the housing 2 Gently remove th...

Page 8: ...to firm trussing Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Trifloods and other devices The pins 1 Earth 2 Signal 3 Signal 3 Link the units as shown in figure 5 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 4 Supply electric power Plug ele...

Page 9: ...Mode you can change d 100 Dimmer from 0 100 F 100 Fade from 0 100 S 100 Fade from 0 100 2 Sound Control Mode When the TriFlood is not connected by a DMX cable it functions as a stand alone device By holding down the Mode Button you can switch to Audio the TriFlood will automatically change its color to the beat of the music With the Audio Sensitivity control you can adjust its music sensitivity By...

Page 10: ...n RGB D C B Mode the device has 3 or 4 channels Mode CH 1 CH 2 CH 3 CH 4 RGB DMX 0 29 Red 0 100 Green 0 100 Blue 0 100 8 Built in programs run automatically DMX 30 94 Dimming 0 100 Fade 0 100 Speed 0 100 8 Built in programs run to sound DMX 95 159 Dimming 0 100 Fade 0 100 Chase automatically DMX 160 184 Dimming 0 100 Fade 0 100 Speed 0 100 Chase to sound DMX 185 209 Dimming 0 100 Fade 0 100 40 Col...

Page 11: ...d should be 1 A001 the DMX address of the second TriFlood should be 1 4 5 A005 the DMX address of the third TriFlood should be 5 4 9 A009 etc Please be sure that you don t have any overlapping channels in order to control each TriFlood correctly If two or more TriFloods are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu Cont...

Page 12: ...htly connected and must not be corroded 2 There may not be any deformations on housings fixations and installation spots 3 Mechanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue The Showtec TriFlood requires almost no maintenance However you should keep the unit clean Otherwise the lig...

Page 13: ...om the wall all cables etc 3 If all of the above appears to be O K plug the unit in again 4 If you are unable to determine the cause of the problem do not open the device as this may damage the unit and the warranty will become void 5 Return the device to your Showtec dealer No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in ...

Page 14: ...controller Signal pin OUT pin 1 earth pin 2 pin 3 DMX Channels 4 Signal input 3 pin XLR male Signal output 3 pin XLR female Lamp Allowed lamp models 3x Showtec R7S 300W 1500 hr ordercode 82281 Versions for other lamps may be produced Please check the specification label on your product Design and product specifications are subject to change without prior notice Website www Showtec info Email servi...

Page 15: ......

Reviews: