Summary of Contents for FP51

Page 1: ...ture and humidity Line level sources conditions Mix Bus 3 5k 3 5k 2 dBV Protected against damage from input overload and shorted outputs Dependent on input control setting Four transformer coupled XLR inputs each micro outputs phonelline switchable with low cut filter and cuing func tions Phantom power for condenser microphone operation OUTPUT Built in tone oscillator permits checking levels and t...

Page 2: ...ns Listed by Underwriters Laboratories Inc listed by Cana dian Standards Association as Certified CONTROLS AND CONNECTORS Power Off On Switch applies power to the FP51 circuitry Channel Levellcue Rotary Controls adjust individual input channel signal levels Each channel can be cued by pulling the control knob outward to the detent position rotating the knob to the desired level and pushing the kno...

Page 3: ...at 4 dBm continuous use Note that hantom Dower loading will increase battery drain With batteries in the battery compartment the FP51 will automatically and silently switch to battery operation should the ac voltage fall below a suitable level Battery condition can be determined using the Batt Check switch on the front panel With the FP51 Power switch on ac tivate the Batt Check switch and observe...

Page 4: ...de gain to maintain a constant line level output as measured on the VU meter since that is the compressor s function Response Rate Adjustment Proper setting of the Response Rate control for different types of program material is determined by subjective factors that is by the operator s individual perception of what con stitutes good sound Generally a slower setting will result in less audible com...

Page 5: ...l protection for output circuit components Metal Oxide Varistor General Electric Co Type No V22ZA1 ACCESSORY The Model A16R Rack Panel Kit consists of a 19in x 3 112in 483 mm x 89 mm precut rack panel and necessary hardware for rack mounting the FP51 with its cover in place and end caps removed in a standard 19 in 483 mm audio rack panel SERVICE WARNING Voltages in this equipment are hazardous to ...

Page 6: ...VU Comp Knob Channel Levellcue Knob Master Level REFERENCE DESIGNATION MP3 PL501 Q201 Q202 Q203 Q306 0308 Q310 0301 Q305 Q311 0312 Q307 Q309 P313 Q315 Q314 R317 R320 R340 R 383 R420 R343 R363 R411 R430 R364 R701 5301 5304 S501 S508 S509 S510 S601 S604 S606 S605 S607 T201 T301 T304 T305 U301 U304 U306 U302 U303 U309 U307 U308 U310 U701 W25 SHURE PART NUMBER OR COMMERCIAL ALTERNATE Duracell MN1604 S...

Page 7: ...PRINTED CIRCUIT BOARDS Component Side PRINTED CIRCUIT BOARDS Solder Side ...