Wall mounted ventilator with heat recovery.

AEROLIFE

Window systems
Door systems
Comfort systems

ORIGINAL OPERATING 

INSTRUCTIONS

Summary of Contents for AEROLIFE

Page 1: ...AERO Wall mounted ventilator with heat recovery AEROLIFE Window systems Door systems Comfort systems ORIGINAL OPERATING INSTRUCTIONS ...

Page 2: ......

Page 3: ...umentation 4 Intended use 4 Safety notices 5 Scope of delivery 5 Installation 6 Unit description 12 Function 14 Commissioning 15 Operation 15 Care and maintenance 16 Accessories 18 Technical data 19 Dimensions 20 Liability 21 Feedback on documentation 21 EU Declaration of Conformity 22 ...

Page 4: ...cations The AEROLIFE may only be mounted in a vertical position The unit may not be installed on diagonal surfaces e g walls ceilings If the unit is to be used in a room with a heating unit that draws air from the room prior authorisation must be obtained from the proper authorities such as the officially appointed district chimney sweep Only operate and or store the AEROLIFE at temperatures betwe...

Page 5: ...d it must be replaced by SIEGENIA the company s customer service department or similarly qualified personnel in order to prevent personal injury or damage to property Only a qualified electrician may perform any work on the 230 V AC mains power supply that is required in order to connect the device All pole safety isolation is required if the customer is fitting the mains cable Current local regul...

Page 6: ...ce must be level plastered min 350 mm 437 mm 75 mm 78 mm 462 mm Step 2 Marking drill holes With in wall mounting and permanent electrical connection 1 Cut out the drilling template along the dotted line for in wall mounting 2 Cut out an opening in the drilling template at the point marked with a cross and draw the end of the cable through the opening 3 Align the drilling template with a spirit lev...

Page 7: ...les 1 Drill core hole ø 120 3 Using a hammer drill at an angle of approx 2 to 5 drill a hole through to the outside wall ø120 3 2 Drill the four marked mounting holes all drill holes ø 8 mm at least 45 mm deep 3 Insert four S8 dowels included in delivery into the drilled holes Note depending on the type of wall e g plasterboard suitable dowels may need to be provided by the customer for inserting ...

Page 8: ...ntil the pipe is firmly seated 2 Fix the transition point with the adhesive tape included in the delivery Pipe and socket piece must be firmly connected Step 6 Removing the front panel 1 Insert screwdriver into the left and then the right opening of the front panel until the underlying snap connection is released at both sides 2 Fold the front panel forwards unhinge and set down on the side ...

Page 9: ...nnecting cable in the cable duct in a clockwise or anticlockwise direction Note The cable must be neatly laid in the cable duct to prevent it from being squeezed or carried through during the installation a b Step 8 Screwing the ventilation unit to the wall 1 Lift the ventilation unit and push the attached pipe through the wall opening 2 Press the ventilation unit firmly against the wall and faste...

Page 10: ... top breakthrough on the terminal box Step 10 Inserting the blower units 1 Insert the top and bottom blower unit and press slightly against the contacts Note The blower units are retained in this position after the front panel has been mounted Yellow round label Spring loaded PVC pin Step 11 Inserting the foam strips 1 Press the foam strips into the hollow cavity between the casing and the top blo...

Page 11: ...the display to test the function of the ventilation unit 5 After the successful test switch off the device Note Check the correct seating of the front panel if the ventilation unit is not functioning Step 13 Mounting the weather grille 1 Apply permanently elastic sealing compound to the outer edge of the pipe and mount the weather grille 2 Press the weather grille firmly against the pipe Two clamp...

Page 12: ...instructions 08 2016 Unit description AEROLIFE 1 Housing base 2 Display 3 Button 4 Housing frame 5 Front panel 6 Air inlet and outlet with closing caps 7 Cable duct 8 Socket piece 9 Mains cable with Euro plug 5 4 1 2 3 6 1 4 6 8 9 7 ...

Page 13: ...ir flow level three possible levels Ventilation Operation of blower units Filter replacement required Note The filter is monitored by the current consumption of the unit If the unit is continually operated at air flow level 1 or 2 the AEROLIFE processor will switch to air flow level 5 for approx two minutes every 8 hours in order to check the filter for measuring reasons The unit then automaticall...

Page 14: ...yed into the room through the two bottom air outlets b a a b b Ventilation elements The heat exchanger absorbs part of the heat in the discharged room air and heats up the fresh air supplied You can fold out the heat exchanger to exchange the filter unit in the heat exchanger The filter unit consists of a cassette filter filter grade F7 which filters over 97 of the pollen from the fresh air and a ...

Page 15: ...y terminals supply 230 V AC even when the front panel has been removed Do not remove the cover of the connecting clamps behind the top housing unit Following the successful installation and electrical connection of the AEROLIFE the unit can be commissioned The Euro plug of the mains cable must be properly connected to the 230 V AC mains power supply via a power socket If the unit has been permanen...

Page 16: ...onnect the unit from the mains power supply Switch off all poles of the feeder on units with permanent connection to 230 V AC mains power supply The fuses may need to be removed Cleaning Important When cleaning the AEROLIFE do not allow liquids to get inside the unit Never use cleaning agents that are aggressive or contain solvents or sharp edged objects as these may damage the surfaces of the cas...

Page 17: ...rom SIEGENIA You can purchase replacement filters from SIEGENIA or from specialist retailers Caution Only activate and remove the specified unit components 1 Insert a screwdriver into the left and then the right opening of the front panel until the underlying snap connection is released at both sides 2 Fold the front panel forwards unhinge and set down on the side 3 Fold the heat exchanger forward...

Page 18: ...wo aluminium edges a b The upper edge of the cardboard strip must close under the top aluminium edge The bottom edge of the fleece filter must be pressed behind the bottom aluminium edge c 6 Reassemble the AEROLIFE in the reverse order Note Check the correct seating of the front panel if the AEROLIFE does not function at once after the filter exchange a b c Accessories Material description Materia...

Page 19: ... 14 9 kWh m a E 46 3 kWh m a A 7 8 kWh m a F 28 9 kWh m a B 65 7 kWh m a A d typology RVU BVU e type of drive multi speed drive f heat recovery system recuperative g thermal efficiency 53 8 h maximum flow rate 60 m h i electric power input 32 W j sound power level 42 dB A k reference flow rate 43 m h l reference pressure difference m specific power input 0 51 W m h n control factor control typolog...

Page 20: ...20 AEROLIFE Original operating instructions 08 2016 Dimensions ...

Page 21: ...antled or partly dismantled and the defect is due to the changes made Exclusion of liability The product and its components are subject to stringent quality controls As a result they function reliably and safely when used correctly Our liability for consequential losses and or claims for damages is excluded except in the case of wilful misconduct or gross negligence or where we are responsible for...

Page 22: ...cuments EN 55014 1 2006 EN 55014 2 1997 A1 EN 61000 3 2 2006 EN 61000 3 3 1995 A1 A2 EN 60335 1 2010 EN 60335 2 80 2003 A1 2004 EN 62233 2008 EN 62233 Br 1 2008 EN 62233 2008 11 EN ISO 12100 2010 RoHS 2011 65 EU This declaration is based on test reports from EMC TestHaus Dr Schreiber GmbH Test protocol 14 317 Siegen 2014 11 03 S Bauerdick site manager The technical documents will be provided by SI...

Page 23: ......

Page 24: ... 85 4861080 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4477700 Russia Phone 7 495 7211762 South Korea Phone 82 31 7985590 Switzerland Phone 41 33 3461010 Turkey Phone 90 216 5934151 Ukraine Phone 380 44 4637979 You can find address details for our interna...