CP 5612 

 

SIMATIC NET 

PG/PC - PROFIBUS 

CP 5612 

Operating Instructions 

 

 

05/2021 

C79000-G8976-C278-04 

Preface 

 

 

 

Description of the device 

 

 

Software installation 

 

 

Hardware installation 

 

 

Configuration 

 

 

Technical specifications 

 

 

Approvals 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 6GK1 561-2AA00

Page 1: ...NET PG PC PROFIBUS CP 5612 Operating Instructions 05 2021 C79000 G8976 C278 04 Preface Description of the device 1 Software installation 2 Hardware installation 3 Configuration 4 Technical specifications 5 Approvals A ...

Page 2: ...perated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Si...

Page 3: ...s processor You will find this documentation on the Product Support pages on the Internet under the following entry link Support https support industry siemens com cs ww en ps Enter the entry ID shown below of the relevant manual as the search item Configuration manual Commissioning PC Stations This provides you with detailed information on commissioning and configuring SIMATIC NET PC communicatio...

Page 4: ...t identified by the registered trademark sign are registered trademarks of Siemens AG SIMATIC NET HARDNET SOFTNET CP 1612 CP 1613 CP 5612 CP 5613 CP 5614 CP 5622 Industry Online Support In addition to the product documentation you are supported by the comprehensive online information platform of Siemens Industry Online Support at the following Internet address Link https support industry siemens c...

Page 5: ...ustrial security functions that support the secure operation of plants systems machines and networks In order to protect plants systems machines and networks against cyber threats it is necessary to implement and continuously maintain a holistic state of the art industrial security concept Siemens products and solutions form one element of such a concept Customers are responsible for preventing un...

Page 6: ...ation siemens com WW view en 50305045 Recycling and disposal The products are low in harmful substances can be recycled and meet the requirements of the Directive 2012 19 EU for disposal of waste electrical and electronic equipment WEEE Do not dispose of the products at public disposal sites For environmentally compliant recycling and disposal of your electronic waste please contact a company cert...

Page 7: ... 1 2 PROFIBUS interface 11 1 3 Meaning of the LED display 12 2 Software installation 13 2 1 Installing the SIMATIC NET PC Software 13 2 2 Uninstalling the SIMATIC NET PC Software 14 3 Hardware installation 15 3 1 Safety notices 15 3 2 Installing hardware 16 3 3 Hardware compatibility 17 4 Configuration 19 5 Technical specifications 21 A Approvals 23 ...

Page 8: ...Table of contents CP 5612 8 Operating Instructions 05 2021 C79000 G8976 C278 04 ...

Page 9: ...properties are as follows Transmission speeds up to 12 Mbps Floating RS 485 connector Linking of up to 32 devices PC PG SIMATIC S7 or ET 200 to form a network segment By linking several segments with repeaters up to 64 nodes can be connected The additional interface signals for a direct link to a PLC Programmable Logic Controller are supported up to 187 5 Kbps Installation in PGs and PCs with a PC...

Page 10: ...device 1 1 Product characteristics CP 5612 10 Operating Instructions 05 2021 C79000 G8976 C278 04 Appearance The following graphic shows the CP 5612 communications processor 1 LEDs 2 PROFIBUS interface PB1 master or slave ...

Page 11: ...ng Input output 1 NC Socket pin 1 is not connected 2 NC M24 Socket pin 2 is not connected With other MPI DP components the return line of the floating 24 V power supply may be via this pin 3 LTG_B Signal line B of the PROFIBUS connector Input output 4 RTSAS RTSAS input signal for direct MPI link The control signal is 1 active when the automation system connected over a special MPI cable is sending...

Page 12: ...tion Green off Incorrect bus parameters defective bus e g short circuit or CP not in operation Green flashing fast yellow off Module not started normal status following reset Green and yellow flashing alternately When using more than one module in a PG PC Identification of the module using a diagnostics tool Green and yellow flashing synchro nously Exception state error in firmware Yellow on DP sl...

Page 13: ... the BIOS of your PG PC Prior to hardware installation Install the software as described in the installation manual SIMATIC NET PC Software You will find this installation manual on the Product Support pages under the following entry ID 77377602 https support industry siemens com cs ww en view 77377602 You should also note the current information on the SIMATIC NET PC software on the Product Suppo...

Page 14: ... The recommended procedure removes the entire SIMATIC NET PC Software on the PG PC not only the driver for the communications processor Uninstall the entire software package as described and recommended in the installation manual SIMATIC NET PC Software You will find the installation manual on the SIMATIC NET PC Software DVD or on the Product Support pages under the following entry ID 77377602 htt...

Page 15: ... up components and modules only by their edges Do not touch the pins or conductors Before opening the PG PC make sure that you discharge any electrostatic charge from your body You can do this by touching metal parts on the back panel of the PG PC pulling the power plug Make sure that you also discharge any electrostatic charge from tools you intend to use for the work on the PG PC Do not operate ...

Page 16: ... a 33 MHz bus clock speed is connected Procedure Note First install the software First install the software before you insert the communications processor in the slot Activated plug and play function The plug and play function must be activated in the BIOS of your PG PC Follow the steps outlined below when inserting the communications processor 1 Turn off your PG PC and pull the power cable connec...

Page 17: ...th a CP 5612 if there is a PCI slot available on the PG PC Note If the previous CP has been removed from the PG PC no configuration changes need to be made You can adopt the configuration of the previous CP To do this you simply need to reload the configuration Note the following When loading the previous configuration the previous CP has priority over the new CP As long as the previous CP is conn...

Page 18: ...Hardware installation 3 3 Hardware compatibility CP 5612 18 Operating Instructions 05 2021 C79000 G8976 C278 04 ...

Page 19: ...STEP 7 Professional TIA Portal Communication Settings COML S7 The steps involved are described in the Commissioning PC Stations manual or in the relevant online helps Compatibility during configuration If there is not yet a CP 5612 in the hardware catalog of your STEP 7 version you can select a CP 5611 A2 or CP 5611 for configuration The CP 5612 is downwards compatible with the configurations of t...

Page 20: ...Configuration CP 5612 20 Operating Instructions 05 2021 C79000 G8976 C278 04 ...

Page 21: ...0 to 3 6 V DC for 3 3 V DC 11 0 to 13 0 V DC for 12 V DC Properties Safety extra low voltage SELV to EN 60950 Current consumption Typical for 3 3 V Typical for 12 V 150 mA 250 mA Effective power loss Typical 3 5 W Permitted ambient conditions Operating conditions Temperature EN 60068 2 1 2 Maximum temperature change 5 to 50 C 10 K h Rel humidity EN 60068 2 78 85 at 30 C no condensation Rapid tempe...

Page 22: ...I card Weight 98 g Dimensions W x H x D in mm 18 x 107 x 125 Electromagnetic compatibility Emission to EN 55022 to FCC Class B Class B Immunity On signal cables Surge to EN 610004 5 Burst to EN 61000 4 3 2 kV 2 kV to discharge of static electricity Contact discharge to IEC 61000 4 2 6 kV to radiated radio frequencies to EN 61000 4 3 10 V m at 80 MHz to 2 GHz 10 V m 50 on load factor at 900 MHz and...

Page 23: ...mall businesses EN 61000 6 3 EN 61000 6 1 Industrial environment EN 61000 6 4 EN 61000 6 2 RoHS Directive The product meets the requirements of the EC directive 2011 65 EU RoHS Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment Applied standard EU L174 01 07 2011 Declaration of conformity You will find the declaration of conformity for th...

Page 24: ...ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Siemens AG is not responsible for any radio television interference caused by una...