background image

Fire & Security Products

Siemens Building Technologies

Card reader

AR6111-MX

Installation

Clock/Data Interface Omron and Wiegand

Summary of Contents for AR6111-MX

Page 1: ...Fire Security Products Siemens Building Technologies Card reader AR6111 MX Installation Clock Data Interface Omron and Wiegand ...

Page 2: ...arried out by the manufacturer l The user is responsible for ensuring that the unit is set up and connected in ac cordance with the recognized technical regulations in the country of installation and any other guidelines valid in the relevant region l Before opening the unit always switch off the power supply and take measure ments to ensure that there is no power to the unit l If an operating dis...

Page 3: ...licable conditions of the R TTE directive 1999 5 EG of March 1999 Equipment Classification according to ETSI EN 300 330 Class 2 FCC ID S4OAR6111 MX This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undes...

Page 4: ...a internal Operating frequency 13 56 MHz transmitter power 200 mW 2 dB Qualified Transponders read serial number ISO14443A Mifare Standard 1k and 4k UID S B MAD Mifare UltraLight UID B Mifare DESfire UID my D proximity UID B ISO14443B my C SLE66CL160S UID ISO15683 my D vicinity I Code SLI TagIT HFI STM LRI512 all UID connecting cable 50 cm LiYY 12 0 2 mm2 Transducer 1 x LED red 1 x LED green 1 x b...

Page 5: ...nted directly onto conductive materials such as metal surfaces metal frames reinforcement or metal plated surfaces as these surfaces will reduce the reader s range The clearance to such surfaces should be at least 30 cm l The distance between readers of the same design should not be less than 30 cm l Before final installation the planned installation site should be checked for suitability 83 5 60 ...

Page 6: ...Data1 violet Data Clock CLS Card Present Data Clock Interface grey LED green brown LED red yellow Beeper blue Hold digital inputs orange RS232 TTL Rx white black RS232 TTL Tx Service Interface white brown N C Notes If an external power supply is used the ground signal from the power supply and the host must be connected The digital inputs can only be connected to Ground Any connection to external ...

Page 7: ...the reader could be configured with a spe cial ConfigCard In this mode the reader accepts only ConfigCards Please contact your supplier to get further information s about ConfigCards After the configuration modes has finished the reader changed into the normal op eration mode Normal Operation Mode In the normal operation mode the LED and the beeper are controlled by the digital inputs When the rea...

Page 8: ...lic of Germany on environment friendly chlorine free paper Dokument Nr Isue 05 2004 We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization ...