background image

Siemens Industry, Inc.

Building Technologies  Division

P/N 315-033008-8

Medium and Large Enclosure Doors

Installation Instructions
Models CAB2-BD/-RD and CAB3-BD/-RD

INTRODUCTION

The Models CAB2-BD/-RD and CAB3-BD/-RD Enclosure Doors from Siemens
Industry, Inc., are used with the CAB2-BB/-RB and CAB3-BB/-RB Enclosure
Backboxes. Two doors, an outer and an inner, are required for each enclosure. The
CAB2-BD and CAB3-BD outer and inner doors are black; the CAB2-RD and CAB3-RD
outer doors are red and inner doors are black.

The outer door consists of the door frame and either two or three removable panels,
depending on the enclosure size (two for the CAB2 and three for the CAB3). Each
removable panel is secured to the door with 10-32 nuts. The removable panels may
be clear (OD-LP), blank (OD-BP/-R), or vented (OD-GP/-R) depending on the applica-
tion. The OD-BP-R and OD-GP-R panels are red. The outer door is attached to the
backbox by hinge pins and secured to the backbox by keyed latch.

The inner door has two or three openings in it for the installation of an operator
interface and other modules. There are eight threaded studs around each opening on
the inner door. These threaded studs allow equipment installation on the door. The
equipment is secured by 10-32 nuts. The inner door is permanently hinged left, is
attached to the backbox by hinge pins, and is secured to the backbox by a ¼ turn
fastener or a 10-32 x 1/2” screw (user provided), if desired.

CAB2-BD/-RD and CAB3-BD/-RD Enclosure Doors are for indoor use only in dry
environments.

PRE-INSTALLATION

Outer Door:

Determine the direction that the outer door is to open. If the door is to open to the
left, no further action is required. If the door is to open to the right, the hinges must
be moved to the right side of the backbox and the outer door lock must be moved to
the left side of the outer door. (See page 2.)

Inner Door:

The handle for the inner door comes taped to the outside of the inner door. Remove
the tape from the handle and from the door. To insert the handle, press the handle
through the front of the opening in the inner door. It will snap into place. (Refer to
Figure 1.)

Summary of Contents for CAB2-BD/-RD

Page 1: ...eyed latch The inner door has two or three openings in it for the installation of an operator interface and other modules There are eight threaded studs around each opening on the inner door These threaded studs allow equipment installation on the door The equipment is secured by 10 32 nuts The inner door is permanently hinged left is attached to the backbox by hinge pins and is secured to the bac...

Page 2: ...of the two rubber bumpers on the right side of the backbox then remove them 2 Remove the upper door hinge turn the hinge upside down and install on the right side of the backbox Refer to Figure 2 OUTER DOOR HINGE 3 Repeat the above procedure for the lower door hinge Figure 1 Inserting Handle Into Opening In Inner Door Figure 2 Outer Door Hinge Revesal ...

Page 3: ... 3 6 On the right side of the backbox remove the lock bracket Reinstall the lock bracket on the left side of the backbox Refer to Figure 3 RUBBER BUMPER LOCK BRACKET 7 Remove the plug s for the lock s on the left side of the door On the right side of the door remove the lock s Reinstall the lock s on the left side of the door Reinstall the plug s on the right side of the door LOCK CAB DOOR PLUG FO...

Page 4: ... P R O O D R E N N I L E D O M N O I T P I R C S E D G N I T N U O M P M D I 6 M C F r o f t e k c a r b e t a l p g n i t n u o M M C B d n a 8 M C S 8 M C L d e r u c e S r o o d n i s d u t s n o s t n u o M s t u n 2 3 0 1 o w t h t i w P S D I e h t s a e z i s e m a s e h t t r e s n i k n a l B t e k c a r b e t a l p g n i t n u o m P M D I d e r u c e S r o o d n i s d u t s n o s t n u o...

Page 5: ...igure 2 The inner door can also be secured with a screw if desired Install the Outer Door 1 Insert the hinge pins on the outer door in the hinges on the backbox 2 Install clear blank or vented removable panel s as required and secure with 10 32 nuts Refer toTable 2 and Figure 8 Figure 7 Installing Blank Plates In CAB2 And CAB3 Inner Doors ...

Page 6: ... n o i t a r e p o m e t s y s r o o d n i s d u t s n o s t n u o M s t u n 2 3 0 1 t h g i e h t i w d e r u c e S R P B D O n e h w e s u r o f e t a l P k n a l B m e t s y s e h t f o n o i t a c i d n i l a u s i v d a e d n e h w r o d e r i u q e r t o n s i d e r i u q e r s i n o i t c e t o r p t n o r f r o o d n i s d u t s n o s t n u o M s t u n 2 3 0 1 t h g i e h t i w d e r u c e...

Page 7: ...oor and secure with the key latch Figure 9 Installing The 12 AWG Ground Straps On The Inner And Outer Doors COMPATIBILITY CAB2 BD RD inner and outer doors can be used with CAB2 BB RB backboxes only CAB3 BD RD inner and outer doors can be used with CAB3 BB RB backboxes only SPECIFICATIONS CAB2 BD RD 26 1 8 W x 1 1 4 D x 44 3 4 L CAB3 BD RD 26 1 8 W x 1 1 4 D x 62 1 2 L ...

Page 8: ...Siemens Industry Inc Building Technologies Division Florham Park NJ Siemens Building Technologies Ltd Fire Safety Security Products 2 Kenview Boulevard Brampton Ontario L6T 5E4 Canada 315 033008 8 ...

Reviews: