background image

 

 

                     

                 

  

  

   

   

Summary of Contents for Fujitsu D1159

Page 1: ... ...

Page 2: ... unseren Produkten Tips Updates usw finden Sie im Internet http www fujitsu siemens com Is there any technical problem or other question you need clarified Please contact one of our service partners your sales partner your sales outlet The addresses of your service partners are contained in the guarantee booklet or in the service address booklet The latest information on our products tips updates ...

Page 3: ......

Page 4: ... 0122 01 22 U41126 J Z156 1 74 ...

Page 5: ...Systembaugruppe D1159 System Board D1159 Technisches Handbuch Technical Manual Deutsch E li h English Ausgabe November 1999 December 1999 edition ...

Page 6: ...ere auch auszugsweise die der Übersetzung des Nachdrucks der Wiedergabe durch Kopieren oder ähnliche Verfahren Zuwiderhandlungen verpflichten zu Schadenersatz Alle Rechte vorbehalten insbesondere für den Fall der Patenterteilung oder GM Eintragung Liefermöglichkeiten und technische Änderungen vorbehalten Intel Pentium and Celeron are registered trademarks and MMX and OverDrive are trademarks of In...

Page 7: ...stem monitoring 7 Hard disk connection 8 LAN port 8 PCI bus interrupts 8 Settings 9 Processor s clock speed 9 Setting USB power jumper 10 Recovering System BIOS switch 2 10 Write protection for floppy disks switch 3 10 Add on modules 11 Installing removing processor 12 Upgrading main memory 13 Installing network board with WOL 15 Replacing the lithium battery 15 Glossary 16 ...

Page 8: ......

Page 9: ...s point This symbol means that you must press the Enter key Texts in this typeface are screen outputs Texts in this bold typeface are the entries you make via the keyboard Texts in italics indicate commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized Important notes Store this manual close to the device If you pass on the device to third parties you...

Page 10: ...To prevent damage to the system board or the components and conductors on it please take great care when you insert or remove boards Take care above all to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be especially careful with the locking mechanisms catches centering pins ...

Page 11: ...559 LAN controller 10 100 Mbit s with RJ45 interface WOL with Magic Packet is supported as is booting from LAN with Bootix LAN BootP or Intel PXE Alert On LAN Fujitsu Siemens system monitoring and temperature management 2 RIMM slots for 64 to 1 Gbyte main memory RIMM memory modules or 1 additional board for SDRAM for 64 Mbyte to 512 Mbyte main memory SDRAM memory modules of the DIMM format Flash B...

Page 12: ...nal temperature sensor I 2 C connector Floppy disk drive controller possible formats 720 Kbyte 1 44 Mbyte The system board supports booting from a 120 Mbyte IDE floppy disk drive 1 external parallel interface ECP and EPP compatible 1 external serial port 16C550 compatible with FIFO 1 internal chipcard reader interface As an alternative this interface can also be used as a second serial port 16C550...

Page 13: ...nd connectors 1 6 2 5 7 3 4 AGP PCI 5 PCI 2 PCI 1 PCI 3 PCI 4 1 PS 2 keyboard port 2 PS 2 mouse port 3 Parallel port 4 Serial port 1 5 USB port 2 6 USB port 1 7 LAN port The components and connectors marked do not have to be present on the system board ...

Page 14: ...ives 1 and 2 primary 6 Fan for CPU 1 processor 1 7 Floppy disk drive 8 Serial chipcard reader interface or serial port 2 9 Fan e g for the optional fan AUX 10 Wake On LAN 11 Cover monitoring 12 I C connector primary SMBus 13 Fan for CPU 0 processor 0 14 Fan e g for the optional fan system 15 USB chipcard reader 16 Temperature sensor AUX The components and connectors marked do not have to be presen...

Page 15: ...ssor is dependent on the setting in the BIOS setup Temperature dependent processor speed control enables a reduced fan speed decreasing noise Fan monitoring Fans that are no longer available blocked or sticky fans are detected Blocked or sticky fans are operated with 12 V pulse voltage Fans removed while the system is switched off are signaled by the Display news LED when the system is switched on...

Page 16: ... as an option This LAN controller supports the transfer speeds 10 Mbit s and 100 Mbit s The LAN controller is equipped with a 3 Kbyte transmission and receiving buffer FIFO and supports the WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN Here Bootix LAN BootP and Intel PXE are supported The LAN RJ45 connector is equipped with a yellow a...

Page 17: ...per 2 Switch block Switch block Switch 1 must be set to off Switch 2 System BIOS recovery RCV Switch 3 Write protection for floppy disk Switch 4 Clear CMOS must be set to off during operation Processor s clock speed The clock frequency of the processor is set automatically It cannot be changed manually ...

Page 18: ...ette please call our customer service center On The System BIOS executes from standard floppy drive A and the inserted Flash BIOS Diskette restores the System BIOS on the system board Off Normal operation default setting Write protection for floppy disks switch 3 Switch 3 is used to define whether floppy disks can be written or deleted in the standard floppy disk drive To write and delete floppy d...

Page 19: ...tor LED shows whether the main memory slots are energized AGP PCI 5 PCI 2 PCI 1 PCI 3 PCI 4 0 1 1 2 3 6 7 4 5 8 9 1 Location 1 for processor 0 CPU 0 with heat sink 2 Location 2 for processor 1 CPU 1 with heat sink 3 Voltage indicator LED 4 Location bank 0 for main memory 5 Location bank 1 for main memory 6 Lithium battery 7 Front Side Bus Mismatch LED 8 PCI slots 1 2 3 4 5 9 AGP slot i AGP slots i...

Page 20: ...ts up A suitable multiprocessor operating system must be used if dual operation is required Installing the processor i If you wish to upgrade the system with a new processor the processor bracket on the system board may need to be replaced beforehand Should it be necessary to replace the bracket please contact our customer service center Depending on the design of the processor housing the heat si...

Page 21: ...s 1 Gbyte Memory modules with different memory capacities can be combined All locations must always be occupied Missing memory modules must be replaced with a C RIMM module This C RIMM module must then be installed in the order of the locations behind the RIMM memory module Location bank 0 RIMM memory module Location bank 1 C RIMM memory module The system board supports a maximum of 32 RDRAM modul...

Page 22: ...right and left of the location outwards 1 Slide the module out of its slot 2 Installing C RIMM module or memory module Note the coding of the module 2 2 Flip the holders on each side of the relevant location outwards Insert the module in the slot 1 while folding the side holders up until the module engages 2 ...

Page 23: ...y voltage You may find further information in the supplied description of the network board Replacing the lithium battery Incorrect replacement of the lithium battery may lead to a risk of explosion The lithium battery must be replaced with an identical battery or a battery type recommended by the manufacturer CR2032 Do not throw lithium batteries into the trashcan It must be disposed of in accord...

Page 24: ...rst In First Out FSB Front Side Bus FWH Firmware Hub GMCH Graphics and Memory Controller Hub I 2 C Inter Integrated Circuit IAPC Instantly Available Power Managed Desktop PC Design ICH I O Controller Hub IDE Intelligent Drive Electronics IPSEC Internet Protocol Security ISA Industrial Standard Architecture LAN Local Area Network LSA LAN Desk Service Agent MCH Memory Controller Hub MMX MultiMedia e...

Page 25: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Reviews: