background image

  

 

 

SIJECT15/16   
Operation Manual

Software Version 1 

User Manual 

06.2003 Edition 

User Documentation 

Summary of Contents for SIJECT15

Page 1: ...SIJECT15 16 Operation Manual Software Version 1 User Manual 06 2003 Edition User Documentation ...

Page 2: ......

Page 3: ... Manual Operator Manual SINUMERIK 802S SIJECT 15 16 Document Structure SINUMERIK 802S Technical Manual Start Up SINUMERIK 802S General Documentation C t l Short Guide for Start up Operation Manual Start up ...

Page 4: ......

Page 5: ...Valid for Control System Software Version SIJECT 15 16 1 08 06 2003 Edition SIJECT 15 16 Operation Manual Software Version 1 User Manual Introduction Operator panel keys SIJECT OP15B Screen 1 2 3 ...

Page 6: ......

Page 7: ...duction of this document and utilization and disclosure of its contents is not allowed unless specifically authorized Violations shall be cause for damage liability All rights reserved particularly in the event a patent is issued or a utility model patent is registered Siemens AG 2003 All Rights Reserved Other functions which are not described in this Documentation can possibly also be performed o...

Page 8: ......

Page 9: ...T OP15B Screens 3 1 3 1 Hot key Screens 3 2 3 1 1 Information Screen 3 9 3 1 2 Monitoring screen 3 12 3 1 3 Alarm screen 3 14 3 1 4 Temperature screen 3 16 3 1 5 Timer screen 3 17 3 1 6 Counter screen 3 19 3 1 7 Function screen 3 20 3 1 8 Save load screen 3 22 3 1 9 Data screen 3 24 3 1 10 Service screen 3 26 3 2 Manual operation screen 3 38 3 2 1 Mold open close screen 3 38 3 2 2 Ejector screen 3...

Page 10: ......

Page 11: ...SIJECT 15 16 Operation Manual June 2003 1 1 1 Introduction Contents Section Heading Page 1 1 Operator panel layout 1 2 1 2 Overview of screens 1 4 1 3 Working process of injection molding machine 1 6 ...

Page 12: ...Introduction SIJECT 15 16 Operation Manual June 2003 1 2 1 1 Operating panel layout Fig 1 1 Operator panel layout ...

Page 13: ...ith the key then control the machine movement manually 5 Number keys 12 keys Input number parameter Create recipe data 5 Cursor keys 6 keys Move the cursor to the required position with Cursor key then press Enter key to confirm the setting Or when screen displays the message press ACK key press ACK key to confirm 7 Operating mode keys 7 keys Select machine mode with Mode key When in Semi Auto Aut...

Page 14: ...ns are listed in Table 1 2 for reference Table 1 2 Hot key screen structure Screen 1 Temperature Screen 1 Timer Screen 1 Counter Screen 1 Function Screen 1 Load save Screen 1 Data Screen 1 Service Screen 1 Version info Screen 2 Data con d Screen 1 1 Password Screen 1 2 Load save Screen 1 1 OEM Screen 1 3 Set prop valve Screen 2 Linear scale Screen 1 Alarm Screen 1 Monitoring Screen 1 1 Event Scree...

Page 15: ... out and core2 in out have the 2nd level that is they are used for core 3 function The parameters like position press flow delay time counter and mode selection can be set in these screens Table 1 3 Screen structure of manual operating keys Screen 1 Mld Clo Opn Screen 1 Eject Screen 1 Carriage Screen 1 Injection Screen 1 Charging Screen 1 Core 1 Screen 1 Core 2 Screen 1 Air blow Screen 1 Mold adju...

Page 16: ...i e SIJECT 15 SIJECT 16 SIJECT 16 international and SIJECT 16DP international version Please see the manufacturer documentation SIJECT 15 16 Start up for detailed information Control process The configuration of individual injection molding machine can be different but the working process should be implemented in a similar way Thus we describe it roughly in the following diagram It is provided in ...

Page 17: ...eding Core 2 out Mold open end Ejector shake Ejector stay Ejector auto retract Counter arrive Cycle end Start cooling time Core 1 out Yes No No Yes No Yes No Yes Yes No No No Stay time Yes No Yes Yes No Shake times arrive Ejector shake Yes Yes Carriage advance Carriage retract Open mold Core 3 out Ejector advance Ejector retract Carriage retract Charging Close mold Air blow Ejector shake time No F...

Page 18: ......

Page 19: ...or panel keys Contents Section Heading Page 2 1 Liquid crystal display 2 2 2 2 Soft keys 2 3 2 3 Screen hot keys 2 6 2 4 Manual operating keys 2 8 2 5 Number keys 2 11 2 6 Cursor keys 2 11 2 7 Operating mode keys 2 12 2 8 Motor keys and heater keys 2 14 ...

Page 20: ...play LCD General The LCD display with CCFL back light has a good performance to display Alarms Recipe data Customer specific picture Operation status Performance The LCD has the following characteristics 320x240 pixel 5 7 Chinese English languages the brightness can be adjusted manually ...

Page 21: ... Event information Selection key Purge start Purge start start up the purge function Injection reset Injection reset execute reset fuction of injection counting Manual Lubrication Manual lubrication lubricate manually Softkey F2 Softkey F2 Operation path and function Page down purge key Purge stop Purge stop stop purge function Product reset Product reset execute product reset function 1 Functions...

Page 22: ...t Pump combination Softkey F3 Softkey F3 Operation path and function Manual lubrication Manual lubrication lubricate manually Digit input save mold parameters into MMC card or CI increase screen brightness increase limit value save program into MMC card set the password set manual lubrication Softkey F4 Softkey F4 Operation path and function digit output load mold parameters from MMC card or CI ...

Page 23: ...ation path and function decrease screen brightness reduce limit value load program from MMC card temperature setting Softkey F5 Softkey F5 Operation path and function proportional valve start up ramp data setting Softkey F6 Softkey F6 Operation path and function Page up ...

Page 24: ...put and the actual value of temperature channel can be displayed as well In addition you can choose the heat holding function and you can set the tolerance of temperature control You can also choose the control mode of nozzle open loop close loop Timer key Press this key to enter Timer screen Every time duration can be set such as cycle time cooling time mold open close time as well as every delay...

Page 25: ... function selection linear scale setting password setting load save setting proportional valve setting pump setting lubrication setting temperature setting and ramp setting When OEM has finished the start up of injection molding machine these parameters will normally be protected by Password 2 by OEM Information key Press Information key to enter Information screen where the version message of OP ...

Page 26: ...efore or after mold close or Core out during before or after mold open Ejector key Press the middle Ejector key to enter Ejector screen Now you can input corresponding parameter Position pressure flow and counter for ejector advance and retract and set counter and ejector mode Ejector will retract continuously if you keep pressing the left key Ejector will advance continuously if you keep pressing...

Page 27: ...utomatically after injection is finished Machine will suck back i e screw retract if you keep pressing the right key Charge key Press the middle Charge key to enter Charge screen Input corresponding parameter Position pressure and flow for charging Screw will be charging if you keep pressing the right key Core 1 key Press the middle Core 1 key to enter Core 1 screen Input corresponding parameter f...

Page 28: ...he left key Air blow 2 will work if you press the right key Press the Air blow key again to enter Core 3 screen Input corresponding parameter pressure position flow and time for core 3 in out Keep pressing the left key to let core 3 in Keep pressing the right key to let core 3 out Mold adjustment key Press the middle Mold adjustment key to enter Mold adjustment screen Input pressure and flow for m...

Page 29: ...or down and the ENTER key and Acknowledge key ACK key When alarm appears and the system message displays on the screen press the ACK key to confirm them Example If you want to input a parameter like pressure or flow of injection first press injection key to enter Injection screen then use cursor keys to go to corresponding field Input parameter using number keys and press ENTER key to confirm your...

Page 30: ...essing RUN key again or safety door is opened closed once Lubrication can be done automatically if the machine has run more times than the lubrication counter setting number Timer Full Auto mode key Set all the parameters necessary including total cycle time press this Timer Full Auto mode key and wait for the LED on Press the RUN key to start the system The machine will execute the cycle automati...

Page 31: ...ut in this mode they are Mold open close ejector advance retract injection suck back charge core 1 in out core 2 in out core 3 in out air blow 1 2 and lubrication purge This mode can also be used to reset the parameters and clear the alarm Mold Adjustment mode key This mode is especially used for mold adjustment when a new mold is installed in the machine Following operations can be carried out in...

Page 32: ...Operator panel keys SIJECT 15 16 Operation Manual June 2003 2 14 Stop key is to stop Semi Auto mode Timer Full Auto mode Sensor Full Auto mode ...

Page 33: ...e used to control the motor and heater Motor key Push the left key to start the motor The motor will be actuated in star mode at the beginning after the delay time it will switch to triangle mode Push the right key to stop the motor Heater key Push the left key to switch on the heater push the right key to switch off the heater ...

Page 34: ......

Page 35: ...3 1 5 Timer screen 3 17 3 1 6 Counter screen 3 19 3 1 7 Function screen 3 20 3 1 8 Save load screen 3 22 3 1 9 Data screen 3 24 3 1 10 Service screen 3 26 3 2 Manual operating key screens 3 38 3 2 1 Mold screen 3 38 3 2 2 Ejector screen 3 40 3 2 3 Carriage screen 3 42 3 2 4 Injection screen 3 43 3 2 5 Charge screen 3 45 3 2 6 Core1 screen 3 47 3 2 7 Core 2 screen 3 50 3 2 8 Air blow screen 3 52 3 ...

Page 36: ...ecific picture CSP will be displayed for 3 seconds After CSP screen the SIJECT OP15B Information screen will be displayed for 3 seconds On this information screen the PLC version OP and CI version will be displayed Then the system will change to monitoring screen automatically Fig 3 1 Customer specific picture screen Fig 3 2 SIJECT OP15B system information screen ...

Page 37: ...le 3 1 Description of Status Indicators Element Indicator Meaning Monitoring screen Main screen Display the working status of injection molding machine The purge and lubrication can be controlled Information screen Display the system infomation OEM picture and the status of input outputs Alarm screen Display 32 alarms and events 1 Current screen Temperature screen Display the set value and actual ...

Page 38: ...or OEM such as linear scale proportional valve password etc Mold open close screen Set the process parameters for 3 mold open close modes Ejector setting screen Set the process parameters for 3 ejector advance retract modes and ejector mode Carriage setting screen Set the process parameters for carriage advance retract and charging mode Injection setting screen Set the process parameters for 4 inj...

Page 39: ...tal quantity and product of this power on on monitoring screen Press Run key and the machine runs automatically The machine will stop when the set product counter is full 2 Current status Mold adjustment status This indicator is flashing under mold adjustment status there are two modes semi auto mold adjustment and manual mold adjustment 3 Cooling time status This indicator is flashing during cool...

Page 40: ... the temperature reaches the set value it will stop flashing 9 Event message When this indicator is flashing it means certain events happened Check the event screen and take correction activities Once the event is eliminated it will stop flashing 10 Alarm message When this indicator is flashing it means certain alarm happened Check the alarm screen and take correction activities Once the event is ...

Page 41: ...r function selection it is requested to use the cursor first Move the cursor to the wanted item and press the Selection key Then press cursor up or down key to select the function and use Enter key to confirm the setting 4 for the basic operating pictures it is necessary to enter password 1 to set parameters for the first power on or after 5 minutes users should input password 1 for the second tim...

Page 42: ... 1 Soft key F1 Used as event record information OEM picture and function selection 2 Soft key F2 When there is a second screen this key is normally used as page down Also it could be used for other functions e g purge key 3 Soft keys F3 F5 Soft keys with assigned functions 4 Soft key F6 Always as return key the key to go back previous screen ...

Page 43: ...SIJECT OP15B Screens SIJECT 15 16 Operation Manual 3 9 3 1 1 Information Screen Fig 3 4 Information screen 1 Fig 3 5 Information screen 1 1 OEM picture ...

Page 44: ...SIJECT OP15B Screens SIJECT 15 16 Operation Manual June 2003 3 10 Fig 3 6 Information screen 1 2 Digit inputs Fig 3 7 Information screen 1 3 Digit outputs Fig 3 8 Information screen 2 ...

Page 45: ...nal See Fig 3 6 Information screen 1 2 digit inputs Users can check the status of each input output Press soft key F4 to display the status of all 40 digit outputs 35 digit outputs for SIJECT15 DQ3 5 DQ3 7 and DQ 4 6 DQ 4 7 are spare The box will backlight if there is a signal See Fig 3 7 Information screen 1 3 digit outputs Force Output is to make certain point force output For example input 3 4 ...

Page 46: ...SIJECT OP15B Screens SIJECT 15 16 Operation Manual June 2003 3 12 3 1 2 Monitoring screen Fig 3 9 Monitoring screen 1 Fig 3 10 Monitoring screen 1 1 event record ...

Page 47: ...ord screen See Fig 3 10 Monitoring screen 1 1 event record screen If there is event message during operation then indicator see table 3 1 is flashing Users should check this screen and take correction activities It is different from alarms Press soft key F2 on monitoring screen 1 to enter the purge screen and the purge time or purge counting can be set Then press softkey F1 Start purge to start th...

Page 48: ...SIJECT OP15B Screens SIJECT 15 16 Operation Manual June 2003 3 14 3 1 3 Alarm screen Fig 3 12 Alarm screen 1 Fig 3 13 Alarm screen 1 1 event record screen ...

Page 49: ...r to check the alarm screen On the alarm screen the box in front of the current alarm is backlight Then users should take corresponding correction activities to clear alarm resource and press acknowledgment key or manual mode key to acknowledge and delete the alarms Press soft key F1 to enter the event record screen See Fig 3 13 Alarm screen 1 1 event record screen This screen can also be called b...

Page 50: ...e if time unit is 20s and nozzle is set as 30 Then heating time is 20 x 30 6s and heating off time is 14s If the nozzle is under close loop control the upper and lower tolerance can be set here which is valid for all temperature zone When the temperature is within specification channel heating will maintain the temperature within this range The indicator see table 3 1 will stop flashing which mean...

Page 51: ...the timer begins to work This interval is to make sure that the material has enough time for cooling Charging delay TdCha It is the interval time between injection and charging which is to prevent the overheating of plastic material Injection delay TdInj When the carriage arrives at the injection position it will wait certain time before injection Core in delay TdCorIn When previous work is finish...

Page 52: ...or advance time TmEjeAdv The total time for ejector advance which is monitoring time There is event message if the setting time is exceeded Ejector retract time TmEjeRet The total time for ejector retract which is monitoring time There is event message if the setting time is exceeded Pre decompression time TmPreDec The total time for pre decompression which is monitoring time There is event messag...

Page 53: ...set on this screen Part counter Part Count Set the production quantity Part numbers for each mold Part Nr Mld Set the production quantity for each mold Shots counter Shot Count Display the number of shots Parts of this power on Parts from Startup Display the production quantity of current power on Softkey F1 Clear shot Press this key and the injection time will be reset Softkey F2 Clear part Press...

Page 54: ...ack light Back Light select or deselect back light function If selected then the screen will be in back light mode automatically after 3 minutes If not selected then the screen will always have display Language Select English or Chinese Examples For robot selection you can do as follows 1 Press key or to enter the robot setting field 2 Press key for the first time it is required to input password ...

Page 55: ...Brightness adjust Press softkey F3 key and the system displays the message Type password Press Enter key and return to function screen Then press softkey F3 again and the screen brightness is increasing On the contrary press F4 the screen will become darker ...

Page 56: ...rd can save 1 30 recipe data And 1 50 recipe data can be loaded from MMC and 1 30 recipe data can be loaded from CI Example For MMC selection you can do as follows 1 Press or key to move the cursor to the save load medium field 2 Press selection key for the first time it is required to input password 1 of 1111 then confirm the entry by Enter key 3 Press or key to select the MMC card 4 Press Enter ...

Page 57: ...SIJECT OP15B Screens SIJECT 15 16 Operation Manual 3 23 3 Press soft key F3 to do the saving The system will display success when saving operation is finished 4 Press to acknowledge it ...

Page 58: ...n 1 and press page down key F2 on this screen to enter the Data screen 2 See Fig 3 20 Data screen 1 and Fig 3 21 Data screen 2 Data screen provides the important data of the latest 10 shots the latest one is always on the top Shot Shot number The latest shot is always on the top Mold open end MldOpn End position of mold open in mm Start injecting InjStr Start position of injection in mm ...

Page 59: ...n mm Ejector advance end EjeEnd End position of ejector advance in mm Mold protection time MProTm Time of low pressure mold protection in second Mold lock time MLckTm Time of high pressure mold lock operation in second Injection time InjTm Total time of 4 stages injection in second Cycle time CycTm Time record of every machine cycle in second Charging time ChaTm Time record of every charging opera...

Page 60: ...ct can be set as position mode or time mode Photo sensor mode CycSenNSTD Photo sensor can be set as normally open mode or normally close mode Lubrication error LubErrNSTD Contactor in alarm circuit can be set as normally open mode or normally close mode Fast mold open FastMldOpn It can be set as normal mode or special mode Motor protection MotStrPro Motor protection can be selected i e if there is...

Page 61: ...ct Range 0 1 9 9 mm Tolerance when mold open MldOpnTol Set the tolerance of mold open Range 1 0 99 9 mm Special parameter 3 SpecPar 3 Spare Special parameter 4 SpecPar 4 Spare Example Select Position at Carriage retract mode CarRetMod 1 Press or key to move the cursor to carriage retract mode field 2 Press key to start the setting mode 3 Press or key to select Position mode 4 Confirm the setting w...

Page 62: ...e can be set here Length setting value The length of linear scale can be set here ranged from 1 6553mm Actual value displayed value Display the actual value of linear scale Current value displayed value It is the difference from actual value to reference point Linear scale ejector Switch Proximity switch signal When ejector retract is at position the box will backlight showing the reference point ...

Page 63: ...lt value of this system is 2000 Retype Password 2 retype the new password 2 and confirm it with Enter Key When the password has been successfully changed the screen will display a message Press Acknowledgment Key to finish the operation Lower Higher password it is the password level 2 The default value of this system is 2000 then confirm it by Enter Key New password 1 a new password 1 can be set h...

Page 64: ... PLC version to show the PLC version in MMC Operating examples To select Menus in Program types Steps are as follows 1 Press cursor key or to enter program type selection 2 Press Selection Key and the cursor moves to the left 3 Press cursor key or to select Menus 4 Press Enter Key to confirm Download Menus from MMC Steps are as follows 1 Plug in MMC card in the CI 2 Select Menus in Program Type 3 ...

Page 65: ...tart valve adjustment Valve Type select the type of valve flow pressure back pressure reserved Valve Limit select min max value Pressure Test in force output mode input pressure value ranged from 0 140bar Flow Test in force output mode input flow value ranged from 0 100 BackPressure Test in force output mode input pressure value ranged from 0 140bar Operating sequences Firstly start valve adjustme...

Page 66: ...tion key and cursor moves to left 3 Use cursor key or to select Max 4 Confirm it with Enter Key 5 Press softkey F3 to increase the Max or use softkey F4 to reduce Max This process can be observed by external amperemeter Lastly check the adjustment result In the Force Output mode implement the Pressure Test 1 Press softkey F2 Force Output and the upper box will backlight 2 Set the value of 140bar i...

Page 67: ...s softkey F2 to enter service screen 2 linear scale setting Then press softkey F2 to enter pump combination setting screen See Fig 3 27 Service Screen 2 1 pump combination setting Pump2 pump3 pump4 can be selected here and the flow can be set accordingly Pump2 Flow flow range 0 100 Pump3 Flow flow range 0 100 Pump4 Flow flow range 0 100 ...

Page 68: ...re Lubrication time and lubrication count can be set here Lubrication Time every lubrication time can be set here ranged from 0 0 99 9sec Lubrication Count set one cycle here and the system will be lubricated automatically The range is from 1 to 9999 Lubrication Status Press softkey F1 manual lubrication to start the lubrication then the box will backlight and is flashing Lubrication Oil Level Inf...

Page 69: ...et the upper limit of hydraulic oil temperature Oil Lower set the lower limit of hydraulic oil temperature Temperature Compensation set the temperature compensation The system has been set the compensation before delivery and it is unnecessary for users to set it again Nozzle Mode two modes are available it can be assigned as close loop or open loop Channel 1 select or deselect Channel 2 select or...

Page 70: ...ps when injection starts and injection completes set pressure and flow for each and the range is from 0 to 99 The values should be the differences for pressure and flow between every two PLC cycles when there is action switch Charge it refers to the ramps when charging starts and charging completes set pressure and flow for each and the range is from 0 to 99 The values should be the differences fo...

Page 71: ...ferences for pressure and flow between every two PLC cycles when there is action switch Core 1 it is the ramp for core 1 in out set pressure and flow for each and the range is from 0 to 99 The values should be the differences for pressure and flow between every two PLC cycles when there is any action switch ...

Page 72: ...low MldClo 1 set position pressure and flow Mold close fast MldClo 2 set position pressure and flow Mold protection with low pressure MldPro set position pressure and flow In addition to protect mold from particles users can set mold protection time here If mold protection with low pressure cannot be finished within the set time the mold will retract to the end position of mold open and send alarm...

Page 73: ...the position pressure and flow of slow mold open Mold open tolorence MldOpnTol set the allowed tolorence of mold open end position When mold is within this tolorence then the system will consider the mold is opened to the end Mold position MldPos display the actual position of the mold Press key to close the mold manually and press key to open the mold manually ...

Page 74: ... 2 EjeAdv 2 During ejector advance users can set position pressure and flow for ejector advance 2 Ejector retract 1 EjeRet 1 During ejector retract users can set position pressure and flow for ejector retract 1 Ejector retract 2 EjeRet 2 During ejector retract users can set position pressure and flow for ejector retract 2 Vibrating position Vibrate Set position here Ejector retracts to this positi...

Page 75: ...gain It advances and retracts according to the set numbers If this item is deselected that means this machine does not use ejector Ejector position EjePos display the actual position of ejector Ejection counter Eje Count when ejector multiple vibration mode is selected users can set the numbers of ejection Press key to forward ejector to remove part from mold manually and press key to retract ejec...

Page 76: ...low and time of carriage retract The time set here is used for monitoring the carriage retract If carriage does not retract to the end during this time then it will send alarm Feeding mode Feed mode there are three modes for feeding fixed front and back Fixed feeding the carriage is fixed first charging then decompression Front feeding the carriage is at the front first charging then decompression...

Page 77: ...the position pressure flow and time of injection 2 Injection 3 Inject 3 set the position pressure flow and time of injection 3 Injection 4 Inject 4 set the position pressure flow and time of injection 4 Transition mode TraMode it refers to the transition mode between injection and pressure holding Three modes can be selected Position mode Time mode and Position Time mode Holding 1 set the pressure...

Page 78: ...and pressure holding If Position mode is selected then the set time is monitoring time The alarm is warning when the time is exceeded If Time mode is selected then the set time is control time The set position value is invalid If Position Time mode is selected then the one who reaches the set value first takes the priority ...

Page 79: ...e is used then the value should be set as backpressure Charging 2 Charge 2 set the position pressure and flow for charging 2 If proportional backpressure valve is used then the value should be set as backpressure Charging 3 Charge 3 set the position pressure and flow for charging 3 If proportional backpressure valve is used then the value should be set as backpressure Charging 4 Charge 4 set the p...

Page 80: ...reens SIJECT 15 16 Operation Manual June 2003 3 46 Screw rotation speed ScwRmp display the actual screw rotation speed In manual mode press charging key to begin charging Release the the key and the charging will stop ...

Page 81: ...counter then the counter should be set and the actual counting value will be displayed Core 1 out set the pressure and flow for core 1 out If it is by position then position value should be set If it is by time then the time should be set as a parameter and the actual time will be displayed If it is by counter then the counter should be set and the actual counting value will be displayed Core 1 se...

Page 82: ...ion by time or by counter Core 3 in set the pressure and flow for core 3 in If it is by position then position value should be set If it is by time then the time should be set as a parameter and the actual time will be displayed If it is by counter then the counter should be set and the actual counting value will be displayed Core 3 out set the pressure and flow for core 3 out If it is by position...

Page 83: ...close during mold close or at the end of mold close Core out position CorOutPos set the position to do core out The core out can be at the start of mold close during mold close or at the end of mold close Mold position MldPos display the current position of mold Press soft key F3 Core in to insert the core into mold and press F4 Core out to do core out ...

Page 84: ...be counter then the counter should be set and the actual counting value will be displayed Core 2 out set the pressure and flow for core 2 out If it is by position then position value should be set If it is by time then the time should be set as a parameter and the actual time will be displayed If it is be counter then the counter should be set and the actual counting value will be displayed Core 2...

Page 85: ...d Press Manual Core 2 in key to do core in manually and press Manual Core 2 out key to do core out Fig 3 39 Core 2 in out screen 2 On Core 2 screen 1 see Fig 3 38 press softkey F5 to enter Core 2 screen 2 See Fig 3 39 Core 3 in out can be set here The operation of core 3 is the same as described in section 3 2 6 ...

Page 86: ...old reaches the position air can blow by the set time Air blow 1 Air 1 select or deselect the air blow 1 When the mold reaches the position air blow will be controlled by the set time Air blow 2 Air 2 select or deselect the air blow 2 When the mold reaches the position air blow will be controlled by the set time Mold position MldPos display the actual position of mold Press Manual Air blow 1 to ac...

Page 87: ...ustment For pulse adjustment users can set pulse value for mold adjustment For automatic adjustment users should first set time If mold adjustment does not finish within the preset time then the system will retract the mold automatically Mold close during mold adjustment MldClo in mold adjustment mode set the pressure and flow during mold close Mold open during mold adjustment MldOpn in mold adjus...

Page 88: ... of mold advance Pulse of mold retract RetPuls in pulse mold adjustment mode set the pulse of mold retract Pulse mold adjustment PulsAdj select or deselect Mold close time MldCloTim in Auto adjustment mode set the mold close time for mold adjustment Users can set an initial value and the system will judge it automatically If mold cannot be adjusted within this time then the system will retract the...

Page 89: ...or Publication Manual SIJECT 15 16 Operation Manual Software Version 1 User Documentation From Name User Manual Order No 6AT1931 5AB41 0KA1 Edition 06 2003 Company Dept Address Telephone Fax Should you come across any printing errors when reading this publication please notify us on this sheet Suggestions for improvement are also welcome Suggestions and or corrections ...

Page 90: ......

Page 91: ......

Reviews: