Introduction 

1

 

Description 

 

2

 

Application Planning 

 

3

 

Installing 

 

4

 

Connecting 

 

5

 

Commissioning 

 

6

 

Dimension drawings 

 

7

 

Appendix 

 

A

 

SIMATIC 

Industrial PC 

SIMATIC IPC547C 

Getting Started 

06/2009 

A5E02411398-01 

 

Summary of Contents for SIMATIC IPC547C

Page 1: ...___ ______________ ______________ ______________ ______________ ______________ Introduction 1 Description 2 Application Planning 3 Installing 4 Connecting 5 Commissioning 6 Dimension drawings 7 Appendix A SIMATIC Industrial PC SIMATIC IPC547C Getting Started 06 2009 A5E02411398 01 ...

Page 2: ...performed by qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described i...

Page 3: ...ection 16 4 Installing 17 4 1 Installing the device 17 4 2 Technical data of the telescopic rails 18 5 Connecting 19 5 1 Connecting peripherals 19 5 2 Connecting the device to power 20 6 Commissioning 25 6 1 Requirements for commissioning 25 6 2 Initial Commissioning Initial Startup 26 6 3 Reinstalling the software 27 7 Dimension drawings 29 7 1 Dimensional drawing of the device 29 7 2 Dimensional...

Page 4: ...Table of contents SIMATIC IPC547C 4 Getting Started 06 2009 A5E02411398 01 ...

Page 5: ...h the device in electronic form as a PDF file on the IPC547C Documentation and Drivers CD The operating instructions provide useful information on many topics such as the hardware expansion options modification of the system configuration and technical data Conventions The term PC or device is sometimes used to refer to the SIMATIC IPC547C product in this documentation Note Safety information To a...

Page 6: ...Introduction SIMATIC IPC547C 6 Getting Started 06 2009 A5E02411398 01 ...

Page 7: ...ks Installation options for DVD ROM drives DVD burners On off button Front door with lock provides protection against dirt and unauthorized access Keep the front door closed during normal operation Diskette drive USB ports Rating plate Status displays Rear view of the device Pos Description Power unit fan Fan aperture Installation option for 60 mm fan Blanking panel Option for installing a cover f...

Page 8: ...ting down the operating system press and hold more than 4 seconds hardware reset CAUTION Data may be lost when the PC performs a hardware reset WARNING The on off button signal does not cut off power to the PC Operator control elements of redundant power supply Pos Description Description On Off switch The on off button signal does not cut off power to the PC Power LED Status display for redundant...

Page 9: ...ADD2 card for digital monitors optional or DMS59 connector of dual head graphics card optional Line in Connector for analog audio source 3 5 mm phono jack Line out Connector for active speakers or headset 3 5 mm phono jack Micro input Connection for microphone 3 5 mm phono jack USB 6 ports for USB devices VGA Connection for VGA monitor KEYBOARD Connection for a PS 2 keyboard VGA 2 VGA connection a...

Page 10: ...EC power connector Description IEC connector for the AC power supply to the device The permitted power range is 100 VAC to 240 VAC Redundant power supply Redundant power supply Pos Description IEC connector for the AC power supply to the device The permitted power range is 100 VAC to 240 VAC On Off switch LED of power supply Alarm reset ...

Page 11: ...ription TEMP Temperature status OFF RED No error Temperature critical CPU device temperature FAN Fan status CPU heat sink fan fault Enclosure fan fault Power supply fan fault HDD Display for hard disk access OFF GREEN No access Access POWER PC operating status display OFF GREEN flashing GREEN Hibernate switched off or unplugged Windows standby PC in operation ...

Page 12: ... Cable disabled Interface disabled Green LED Link status display GREEN Active cable connected OFF No cable connected Cable disabled Interface disabled No activity Ethernet LAN 1 2 Yellow LED Activity status display YELLOW Data transfer active For unique labeling the LAN interfaces are numbered on the housing The numbering by the operating system may deviate from this ...

Page 13: ...develops on or inside the device If condensation develops wait at least 12 hours before switching on the device 3 2 Unpacking and checking the delivery unit Unpacking the device Note the following points when you unpack the unit It is advisable not to dispose of the original packing material Keep it in case you have to transport the unit again Please keep the documentation in a safe place It is re...

Page 14: ...gure 3 1 Rating plate Order number of the device Ethernet address The Ethernet address of the device is available in BIOS Setup F2 function key at Info F1 function key LAN Address Microsoft Windows Product Key on the Certificate of Authenticity COA The COA label is attached to the inside of the front door You may need the Product Key in case you reinstall the operating system Figure 3 2 COA label ...

Page 15: ...le locations with acidic vapors or gasses without additional protective measures such as the provision of clean air Keep the PC out of direct sunlight Mount the PC as safely as possible to prevent danger for example of falling over The device conforms to protection class IP 30 at the front panel The clearance in the area of the ventilation slots must be at least 50 mm so that the PC is sufficientl...

Page 16: ...rotection The access protection of the device exists only when the front panel is closed and no keyboards with an On Off button power button are being used Note In Windows you have the option of setting the function of the On Off button to meet your requirements You can make these setting in the Power Options menu ...

Page 17: ...ds Mounting with cabinet brackets Mounting on device bases Tower installation a separate tower kit can be ordered for tower installation not available in some countries Mounting on telescopic rails These telescopic rails allow you to fully extract the device out of the cabinet or rack Refer to the sections Technical data of the telescopic rails Page 18 and Dimensional drawing for the use of telesc...

Page 18: ...e from Rittal for this purpose Rittal Type TE 7000 620 Rittal Type VR 3861 580 Rittal Type DK 7063 710 Please refer to the case manufacturer s instructions regarding device bases CAUTION Risk of injury It is not permitted to mount the device only on the 19 brackets of the front panel 4 2 Technical data of the telescopic rails Ultimate load per pair At least 30 kg Full extraction length At least 47...

Page 19: ...y CAUTION Strictly adhere to the specifications for peripheral equipment NOTICE The connected or added peripherals must not introduce any counter emf into the device A counter e m f greater than 0 5 V to ground on the 3 3 V DC 5 V DC 12 V DC voltage due to a connected or integrated component can prevent normal operation or even destroy the computer When measuring the counter emf remember the follo...

Page 20: ...mains voltage CAUTION The mains connector must be disconnected to fully isolate the device from mains Ensure easy access to this area A master mains disconnect switch must be installed if the device is mounted in a switch cabinet Always ensure free and easy access to the power inlet on the device or that the safety power outlet of the building installation is freely accessible and located close to...

Page 21: ...installed For the USA and Canada A CSA or UL listed power cord must be used for the United States and Canada The connector must be compliant with NEMA 5 15 120 V AC power supply A flexible power cord approved to UL and with CSA label should be used It should have the following features Type SJT with three leads min 18 AWG conductor cross section max length 4 5 m parallel grounding plug 15 A min 12...

Page 22: ...order to avoid unintentional disconnection of the power cord Steps for securing the power plug 1 Remove the fastening screw on the power supply module 2 Fasten the power plug interlock to the power supply module WARNING If the power plug is secured with a clamp the power outlet must be freely accessible to allow the device to be easily removed from the mains ...

Page 23: ...ing the device to mains redundant power supply 1 Connect the IEC connector 2 Plug both power cords into the power outlet at the same time Note You will hear a warning signal if the power supply is not established at the same time You cancel the warning signal by pressing button 3 Operate on off button of power supply The LED on the power supply will be lit green ...

Page 24: ...Connecting 5 2 Connecting the device to power SIMATIC IPC547C 24 Getting Started 06 2009 A5E02411398 01 ...

Page 25: ... peripheral devices such the keyboard mouse monitor and the power supply are connected The operating system of your device is preinstalled on the hard disk CAUTION Risk of damage to the device Make sufficient allowances for the device to acquire room temperature before you put it into use If condensation develops wait at least 12 hours before switching on the device ...

Page 26: ...CE The PC may not be switched off at any time during the entire installation procedure Do not change the default BIOS settings otherwise the operating system setup may become corrupted 4 Automatic restart After you have entered all necessary information and after the operating systemsetup is completed the PC is automatically restarted and displays the user interface of the relevant operating syste...

Page 27: ... to integrate additional languages you will need to subsequently install them from Recovery CD2 or DVD Documentation and Drivers CD Contains the documentation and the hardware drivers Restore DVD Contains a hard disk image file with the original factory software operating system with installed hardware drivers Restoring the factory state Place the Restore DVD into the drive and restart the device ...

Page 28: ...Commissioning 6 3 Reinstalling the software SIMATIC IPC547C 28 Getting Started 06 2009 A5E02411398 01 ...

Page 29: ...ATIC IPC547C Getting Started 06 2009 A5E02411398 01 29 Dimension drawings 7 7 1 Dimensional drawing of the device 9HUWLFDO LQVWDOODWLRQ 9HUWLFDO LQVWDOODWLRQ 18 5 Figure 7 1 Dimension drawing of the device ...

Page 30: ...e of telescopic rails LPHQVLRQV PP LQFKHV ಯ 7 7ROHUDQFHV RI s PP ಯ 7 7ROHUDQFHV RI s PP ಯ 7 7ROHUDQFHV RI s PP ಯ LPHQVLRQV IRU WHOHVFRSLF UDLO IURP 6FKURII 7 SH LPHQVLRQV IRU WHOHVFRSLF UDLO IURP 5LWWDO W SH 7 SH 53 IRU PP FDELQHW 7 SH 53 IRU PP FDELQHW s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 s7 Figure 7 2 Dimension drawing for the use of telescopic rails ...

Page 31: ...armonics and EN 61000 3 3 1995 A1 2001 A2 2005 voltage fluctuations and flicker Low voltage guideline The devices complies with the requirements of the EC Directive 2006 95 EC Low Voltage Directive Conformance with this standard has been verified according to EN 60950 1 Conformity certificates The EC declaration of conformity and the corresponding documentation are made available to authorities in...

Page 32: ...s has been certified by DQS the German society for the certification of quality management systems EQ Net certificate no DE 001108 QM Software License Agreement The device is shipped with preinstalled software Please observe the respective license agreements Certification for the USA Canada and Australia Security The following approval is available for the device Underwriters Laboratories UL to St...

Page 33: ... to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations Modifications Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Conditions of operations This devi...

Page 34: ...t technical support for all Industry Automation and Drive Technologies products by Phone 49 180 5050 222 Fax 49 180 5050 223 0 14 min from the German landline network deviating mobile communications prices are possible E mail support automation siemens com Internet Online support request form http www siemens com automation support request When you contact the customer support please have the foll...

Page 35: ...dentification data 14 Initial commissioning 26 K Keyboard 9 M Microsoft Windows Product Key 14 Monitoring Status displays 11 12 Mounting Mounting locations 17 Mounting methods 17 Mounting holes 17 O Operating system 25 Initial commissioning 26 Operator controls 8 Order no 14 P Peripherals 19 Pollutant class 15 Ports Ethernet 9 PROFIBUS 9 Power supply 10 Connecting 20 Protection class 15 R Rear vie...

Page 36: ...SIMATIC Industrial PC SIMATIC IPC547C Getting Started 06 2009 A5E02411398 01 36 ...