background image

Montageanleitung für / Assembly Instructions for SIMATIC NET IE FC RJ45 Plug 180      6GK1901-1BB10-2Axx

Copyright © 2017 Siemens AG

1. Use the green knife cassette

6GK1901-1GB01 (5.1 mm knife clearance)
in the stripping tool.

If your stripping tool was supplied with a
yellow knife cassette, the cutting depth must
be adjusted with the middle socket-head
screw after fitting the new cassette!

2. Take the stripping tool in your right hand.

3. Measure the cable length against the

measuring template. Use your left index
finger as the limit stop.

4. Insert the cable into the stripping tool. Your

left index finger is the limit stop.

5. Tighten the stripping tool fully.

6. To strip the insulation, turn the tool in the

direction of the arrow
   - approx. 4 times for PVC insulation,
   - approx. 8 times for PUR insulation.

7. Keeping the stripping tool closed, pull it off

the end of the cable along with the jacket
and remnants of the shield.

8. If the white filler is not removed with the

insulation, remove it and the transparent
protective foil with your hand.

9. Cut off the dummy cores.

10.  Spread out the wires according to the

color markings on the contact elements of
the connector.

11.  Make sure to observe a length of

approximately 18 mm.

12.  Open the holder cover (e) until it latches

and push in the wires according to their
color coding* as far as the limit stop in
the holder cover

13.  Push the cable into position as shown in

the picture (see arrows). Press down the
contact elements as far as the limit stop
to contact the wires.

14.  Make sure the length of the cores

corresponds to the dimensions stated in
the assembly instructions for the
respective plugs.

15.   Close the cover by pressing together the

two halves of the lock. In doing so, make
sure not to exert pressure on or damage
the latch spring.

16.  Turn the locking mechanism with your

hand as far as possible in the direction
of the arrow.

17.  Insert a 2.5 mm screwdriver into the hole

in the locking mechanism and turn it as
far as the limit stop.

18. The connector is correctly locked when

the opening of the locking mechanism is
pointing to the side and the surfaces are
flush with the surface of the connector.

19.  Releasing the plug

Insert the plug into the socket and push
the spring down to unlock the plug and
release it from the socket again.
If space is limited, release the plug
using a screwdriver (2.5 mm-wide
blade).

green

5

18

90

o

38mm

Summary of Contents for SIMATIC NET

Page 1: ...rding to the color markings on the contact elements of the connector 11 Make sure to observe a length of approximately 18 mm 12 Open the holder cover e until it latches and push in the wires according to their color coding as far as the limit stop in the holder cover 13 Push the cable into position as shown in the picture see arrows Press down the contact elements as far as the limit stop to conta...

Page 2: ...ut off Don t pull while unlocking the plug To create a crossover cable combine the wires in the connector at one end according to the following scheme Connect white with yellow Connect blue with orange When using devices without a securing collar make sure to provide strain relief for the cable as closely as possible to the device You will find information on network structures in the SIMATIC NET ...

Page 3: ...1 870 2D IE FC TP Trailing Cable 2x2 6XV1 840 3AH10 IE TP Torsion Cable GP 2x2 6XV1 870 2F IE FC TP Marine Cable 2x2 6XV1 840 4AH10 IE FC TP Food Cable 2x2 6XV1 871 2L IE FC TP Festoon Cable GP 2x2 6XV1 871 2S IE FC TP FRNC Cable GP 6XV1 871 2F IE FC TP Standard Cable 6XV1840 2AU10 Nachfolgend finden Sie Informationen in deutscher Sprache Die aktuellen Hinweise finden Sie auf folgender Internetsei...

Page 4: ...inweise sind Personen die mit Aufstellung Montage Inbetriebsetzung und Betrieb dieses Produktes vertraut sind und über die ihrer Tätigkeit entsprechenden Qualifikation verfügen und in erster Hilfe geschult sind _________________________________________________________________________________________ We have checked the contents of this manual for agreement with this tool described Since deviations...

Page 5: ...n Farbmarkierungen auf den Kontaktier elementen des Steckers auf 11 Achten Sie darauf dass die Länge von ca 18mm eingehalten wird 12 Öffnen Sie die Aufnahmeklappe bis diese einrastet Führen Sie die Adern bis zum Anschlag in die Kontaktier elemente des Steckers ein 13 Schieben Sie das Kabel in Position wie im Bild dargestellt siehe Pfeile Drücken Sie die Kontaktierelemente bis zum Anschlag hinunter...

Page 6: ...abgeschnitten werden Entriegeln Sie den Stecker nicht unter Zug Für die Herstellung eines Verbindungs kabels mit gekreuzten Adern kombinieren Sie an einem Kabelende die Adern mit den Farbmarkierungen im Stecker nach folgendem Schema weiß mit gelb verbinden blau mit orange verbinden Achten Sie darauf dass bei Einsatz von Geräten ohne Haltekragen eine Zugentlastung der Leitung möglichst nahe am Gerä...

Reviews: