background image

A6V10331032_j_en_--

Building Technologies

2019-01-24

Control Products and Systems

Sinteso™ Cerberus™ PRO

FDA241, FDA221

ASD Aspirating smoke detector

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET

detector line or for standalone operation

  Patented technology

  Early detection of a wider spectrum of particle sizes in the air

  Configuration using the USB interface or the control panel via FDCC221S

(optional)

  'ASD Asyst-Tool' software to assist with pipe configuration

  Unique dust-resistant detection chamber

  Intuitive front indicator for airflow and smoke value

  Access to service functions

  Different event protocols

  Offline/online configuration supported

  Cleaning function (FDA241)

  4…20 mA output

Summary of Contents for Sinteso Cerberus PRO FDA221

Page 1: ...on Patented technology Early detection of a wider spectrum of particle sizes in the air Configuration using the USB interface or the control panel via FDCC221S optional ASD Asyst Tool software to assist with pipe configuration Unique dust resistant detection chamber Intuitive front indicator for airflow and smoke value Access to service functions Different event protocols Offline online configurat...

Page 2: ...lds ASD filter box FDAZ292 available as an accessory Dust and other dirt is filtered out of the aspirated air and does not get into the aspirating smoke detector The filters in the ASD filter box are easy to replace Use Aspirating smoke detectors are used for early detection of smoke generating fires in rooms and equipment They are especially suited to applications in which point detectors are pus...

Page 3: ...industry Subway stations Agricultural operations All other applications with visible dust load Functions Indication The display contains clear comprehensible bar graphs for smoke and airflow as well as an alarm indicator an error indicator and a dust indicator FDA241 When the housing cover is open the operator has access to the Reset Normalize Smoke and Normalize Flow functions as well as the mini...

Page 4: ...amage to the connection cable when positioning the housing cover make sure that the connection cable has been routed correctly The service area for the detector can be accessed in two ways Partial access Remove the two screws on the top of the detector Slide the housing cover up until you hear it snap into place Full access Remove the two screws on the top of the detector Slide the housing cover u...

Page 5: ...ip or a watchmaker s screwdriver to press the button in the opening Once you have finished with this function press the button in the opening again The smoke detector uses standard values for monitoring during normalization Normalization of the smoke density To determine the nominal air quality in relation to the smoke density perform this function during commissioning The nominal value establishe...

Page 6: ... NET the alarms and the associated relays are not reset USB connection You can use a mini USB cable to connect the detector to a Windows PC To set up the detector use the configuration tool FXS2051 ASD Configuration Tool Test function LED Hold the Buzzer silence button down for 5 seconds The LEDs on the display are tested with 3 different brightness settings If the aspirating smoke detector is to ...

Page 7: ... and a yellow LED With potential free relay contacts for fault messages Additional installation of an I O module possible Uninterruptible power supply with battery charging Batteries max 17 Ah Dimensions W x H x D 430 x 399 x 124 mm Battery FA2003 A1 12 V 7 Ah VdS For supplying fire control panels and aspirating smoke detectors with power Compatible with Fire control panels for the Sinteso and Cer...

Page 8: ...ll find more information in document A6V10916366 FDAZ292 ASD filter box Filter box for installation in the pipe system for aspirating smoke detectors Filters dust and other dirt out of the air aspirated by the aspirating smoke detector Minimizes internal contamination of the aspirating smoke detector Contains filter set FDAZ292 AA with three filters coarse medium fine Compatible with the aspiratin...

Page 9: ...tector FDA241 FDA221 A6V10393194 Technical manual Power supply kit A 70 W FP120 Z1 A6V10345654 Installation Mounting Aspirating Smoke Detectors FDA241 FDA221 A6V10340094 User Manual ASD Asyst Tool FXS2055 A6V10728226 User Manual ASD Asyst Tool V2 FXS2056 A6V10334435 Planning Installation ASD Pipe system A6V10332759 Installation Operation Manual Configuration ASD Configuration Tool FXS2051 A6V10877...

Page 10: ...ust correspond to the calculation made using the FXS2056 ASD Asyst Tool V2 software Air intake exhaust pipe Metric 25 mm outer diameter OD Monitoring area dependent on local provisions and standards Up to 800 m Up to 500 m System compatibility Compatible with all Siemens FC20 FC720 FS20 FS720 systems Relay alarm outputs Can be selected with without lock Nominal current 2 0 A at DC 30 V Contact NO ...

Page 11: ...latile event memory with time and date stamp for smoke density airflow detector status and faults Normalization of smoke value and airflow Setting of threshold values for smoke alarms and faults User setting for normalization of smoke density and airflow Preset values are retained during the normalization period Warranty period 2 years Approvals VdS FDA241 G213050 FDA221 G213050 1 A weighted sound...

Page 12: ...0 or http siemens com bt download 13 FDA221 FDA241 Aspirating smoke detector for use in fire detection and fire alarm systems installed in buildings 305 2011 EU CPR EN 54 20 EN 54 17 2014 30 EU EMC EN 50130 4 EN 61000 6 3 2011 65 EU RoHS EN 50581 DoP No 0786 CPR 21270 DoC No CED FDA221 FDA241 FDA221 FDA241 0786 Siemens Schweiz AG Theilerstrasse 1a CH 6300 Zug Technical data see doc A6V10334410 The...