background image

Product Release Letter (English)

©SIEMENS A&D SE

24.01.2003

(ES4/Ka/WW8.0/A4)

C8451-A6-A83-4-7418

1

Power Supply SMP16-SV430
Order No: 6AR1306-0DC00-0AA0

FEATURES

• 

Offline power supply unit with output for +15 V and –15 V

• 

Input voltage range 94 to 264 V AC

• 

Softstart: No U

a

overswing at switch-on

• 

Slide-in module for 19-inch subrack (for individual locking)

WARNING NOTES

Trouble-free and safe operation of the unit is dependent on proper
transport and storage, as well as installation by qualified personnel.

Installation of the device requires that the applicable DIN/VDE
regulations or the safety regulations of your country be adhered to.

Warning

Protective ground (PE) must be connected with the
protective conductor of the power network of the power
company.

Caution

The device may only be used within the permitted input
voltage range.

Danger of electric shock

Since certain parts of electrical devices inevitably carry
dangerous voltage when these devices are operated,
incorrect handling of these devices may cause death or
serious injury as well as substantial property damage.

Caution

Electrostatic Sensitive Device (ESD)

CONNECTOR ASSIGNMENT

4

6

8

10

12

14

16

18

20

22

24

26

28

30

32

L

PE

1)

N

2)

2)

1)

-15VL

0VL

0VL

1)

+15VL

1)

1)

1)

Signal Description

L, N

Input voltage

PE

protective conductor,
leading pin

1)

Used internally.
Do not connect.

2)

Protective conductor
potential

+15VL

Output voltage 1

–15VL

Output voltage 2

0VL

GND for outputs

Caution

The counter plug connector must be equipped with tin-
plated contacts.

INSTALLATION

The power supply may only be mounted and wired by qualified
personnel who are familiar with and observe the general rules of
this technology and the applicable regulations and standards.

This board may only be installed or removed when the voltage
is off.

To ensure proper ventilation, the device must be mounted vertically
so that the ventilation slits are pointing up or down. A free space of
at least 5 cm must be provided both above and below the device so
that convection is not obstructed.

Parallel circuiting of the outputs of several power supply boards is
not permitted.

For more information on installing and handling SICOMP boards,
see SICOMP IMC System Manual.

STANDARDS/CERTIFICATIONS

Galvanic isolation input/outputs

Test voltage

2.5 kV AC

SELV in acc. w. EN 60950

Overvoltage category II

Electromagnetic compatibility

Power feedback

Class A in acc. w.

EN 61000-3-2

Interference emission
(EN 50081-1)

Class B in acc. w. EN 55022

in reference system

Interference immunity
(EN 50082-2)

EN 61000-4-2/3/4/5/11

Certifications

CE

TECHNICAL SPECIFICATIONS

Input

Input voltage range

94 ... 264 V AC

Input frequency

50/60 Hz

Efficiency

η

80%

Operation indicator

LED

Outputs

Continuous short circuit

protected, idle-proof

Rated output voltage U

AN

Output 1

+15 V DC

Output 2

–15 V DC

Tolerance on delivery

±5%

Temperature coefficient

0.025% / K

Deviation, dynamic:

±0.2%

Recovery time for 0.2 to 0.8 x I

AN

<

0.5 msec

Residual ripple:

<

20 mV

ss

Total interference voltage

<

50 mV

ss

Switch-on delay

1 s

Power failure bypass

40 msec at 100% load

Rated output current I

AN

1.5 A

1.5 A

Overload protection at:

ca. 2.2 A

Overvoltage protection

125% ±5% automatic return

Ambient conditions

Permissible ambient temperature

- during operation:
- during transport/storage:

0 °C to +55 °C

–25 °C to +85 °C

Power reduction above 50 °C

2.5% / K

Relative air humidity:

5 to 90%, no condensation

Degree of protection (EN 60529)

IP 20

Degree of protection (VDE 0106
Part 1)

I

General Specifications

Design:

19" plug-in unit,

individual locking

Plug connector (male connector):

DIN 41612-H15, tin plated

Weight:

approx. 0.5 kg

Dimensions:

- Width
- Height
- Length

8 TE (2 slots)

3 HE

160 mm