Train the Trainer     -

August 2007 

Door / Window Contact Smoke Detector

Synco living

Train the Trainer

Mounting
Safety Devices

August 2007

Summary of Contents for Synco living AP260

Page 1: ...Page 1 11 Train the Trainer August 2007 Door Window Contact Smoke Detector Synco living Train the Trainer Mounting Safety Devices August 2007 ...

Page 2: ...oor Window Contact Smoke Detector Mounting Auxiliary Equipment Mounting the Door Window Contact Door window contact AP260 The door window contact is supplied complete with Installation Instructions battery magnetic contact and fixing material ...

Page 3: ...commended to secure the RF sensor C1 to the door window frame and the magnet C3 directly to the edge of the door itself or the window s wing It must be ensured that the SIEMENS logo on the mounting plate C2 and that on the magnet C3 are aligned above one another and that the distance between the magnetic plate and the edge of the door or window is a minimum of 3 mm and a maxi mum of 10 mm ...

Page 4: ...AP260 Prior to attaching the RF sensor E1 to the mounting plate E2 the transit tab D4 at the rear of the RF sensor in the battery compartment D1 must be removed Place the RF sensor E1 on the mounting plate E2 and slide it in the direction of the arrow until it engages in the catches E3 Function check When opening or closing the window or door the LED briefly lights up twice ...

Page 5: ...w contact AP260 For example to replace the battery of the door window contact the RF sensor H1 must be removed from its mounting plate To do this insert a tool e g a small screwdriver H4 into the slot between RF sensor H1 and mounting plate H2 press the holding nose H3 down and slide the RF sensor H1 to the left over the holding nose out of its catches H5 ...

Page 6: ...Detector Mounting Auxiliary Equipment Mounting the Smoke Detector DELTA reflex smoke detector The DELTA reflex smoke detector is supplied complete with Installation Instructions batteries and fixing material Per room maximum 1 DELTA reflex smoke detector can be fitted ...

Page 7: ... Detector Mounting Auxiliary Equipment Mounting the Smoke Detector DELTA reflex smoke detector To enable the DELTA reflex smoke detector to deliver an alarm via radio link it requires a smoke detector module M255 DELTA reflex smoke detector Smoke detector module M255 ...

Page 8: ...ved Every smoke detector can cover an area of max 60 m2 Fit the smoke detector as close as possible to the center of the ceiling minimum distance from wall and corner 15 cm In rooms with inclined or pointed ceilings fit the smoke detector approx 90 cm from the highest point of the ceiling In the case of rooms having a height of more than 3 m several smoke detectors are required mounting height on ...

Page 9: ...ited mounting locations for the DELTA reflex smoke detector In rooms where considerable amounts of water vapor dust or smoke occur In rooms with open fire places In the vicinity of electrical fields e g fluorescent energy saving lamps and wiring minimum distance 50 cm At locations where ambient temperatures drop below 0 C or exceed 50 C ...

Page 10: ...tector module Removing the module s cover Insert a screwdriver in the respective opening and push it downward to lift the cover Hold the smoke detector module at the edges insert it in its respective place and push it downward until the module s 2 lateral catches engage Replace the cover to prevent malfunctions caused by pressure variations or air drafts ...

Page 11: ...holding firmly the base and turning the detector counterclockwise Secure the base B1 to the ceiling using the enclosed fixing material Insert the 3 enclosed batteries B2 in the battery compartment observe correct polarity Place the smoke detector in the base and secure it by turning it in clockwise direction Use the red triangles as an orientation aid The smoke detector can be secured in its base ...