background image

Printed in India, Subject to change without Notice

User Manual

Analog-Digital Multimeter

Gamma 10

IC 2-60-006-00-00555/REV

:A/15/05/2013

P R E C I S I O N    I N S T R U M E N T A T I O N

Manufactured by:

Sifam Tinsley Instrumentation Inc

3105 Creekside Village Dr, 

Unit 801, Kennesaw GA 30144

Distributed by:

Veracious Canada Inc

1101 Britannia Rd E, 

Mississauga, ON L4W 3X1

Contact: +1 416-640-5364

Fax:       +1 416-981-3933

E-mail:   info@veraciousinc.ca

Web:      www.veraciousinc.com

Summary of Contents for Gamma 10

Page 1: ... 2013 P R E C I S I O N I N S T R U M E N T A T I O N Manufactured by Sifam Tinsley Instrumentation Inc 3105 Creekside Village Dr Unit 801 Kennesaw GA 30144 Distributed by Veracious Canada Inc 1101 Britannia Rd E Mississauga ON L4W 3X1 Contact 1 416 640 5364 Fax 1 416 981 3933 E mail info veraciousinc ca Web www veraciousinc com ...

Page 2: ...ased along with this card and relevant cash memo Invoice This warranty entitles you to bring the meter accessories at your cost to the nearest stockiest dealer and collect it afterrepairs NOTRANSPORTATIONCHARGESWILLBEREIMBURSED Thewarrantyisnotvalidinfollowingcases 1 Warranty card duly signed stamped and original cash memo invoice are notsentalongwiththemeter accessories 2 Completewarrantycardisno...

Page 3: ...s and safety precautions 4 2 Switching the meter on 5 3 Function and range selection 6 3 1 Autoranging 6 3 2 Manual range selection 6 4 Liquid crystal display 7 4 1 Digital display 7 4 2 Analog indication 7 4 3 Backlit 7 5 DATA hold compare facility 7 6 Minimum value and maximum value MIN MAX storage facility with time display 8 7 Voltage measurement 8 7 1 Voltage measurement on electrical systems...

Page 4: ...fe and proper condition of the meters and to ensure their safe operation it is absolutely necessary to carefully and completely read these operating instructions before using any meter These instruction must be followed in all respects For your safety and for protection of the meter the Gamma 10 meter is fitted with an automatic terminal blocking system It is coupled with the function selector swi...

Page 5: ...he cause of the overload before using the meter again Meaning of the symbols on the device Warning of a danger point Attention refer to documentation Ground connector Double or reinforced insulation CAT II III IV Instrument for a overvoltage catagory II III or IV EU conformity mark For US Canada Repair replacement of parts and calibration When opening the meter live parts may be exposed Therefore ...

Page 6: ......

Page 7: ...divisions so that variations of the measured values around zero can be observed exactly When the measured value exceeds the range of indication the left triangle 16 is shown before the polarity of the analog indicator switches over after approximately 0 7s Exceeding of the measuring range 30999 digits on the range F 3099 is shown by the right triangle 13 The graduation of the analogue scale is aut...

Page 8: ...tion you can hold the minimum and the maximum measured value which was applied to the input of the meter after activating MIN MAX The most important application is the determination of the minimum and the maximum value for long term monitoring of measured quantities The function MIN MAX can be activated in all ranges except for the diode test However for frequency and capacitance measurement the r...

Page 9: ...tant the pushbutton is pressed is used as reference value max 2000 digits It is automatically deducted from the values measured thereafter you can clear the zero adjustment by pressing the yellow multi function pushbutton 5 for a long time clearance is acknowledged by the buzzer sounding twice by switching the instrument off 7 1 Voltage measurement on electrical systems up to 1000 V with the KS30 ...

Page 10: ... dB V V V mA 0 C A Voltage Measurement on electrical system up to 1000 V with the KS30 measuring adapter 1 min continuou sly 1 min 7 Range 3V 30V 300V U 1V 10V e eff rms eff rms U 10V 100V e eff rms eff rms U 100V 1000V e eff rms eff rms 8 Without sensor ...

Page 11: ...power systems when the current circuit is protected by a fuse or a circuit breaker of 20 A and when the nominal Note The multimeter does not contain termination resistors The input impedance is 5 MΩ respectively In order to measure correctly on unterminated objects you have to connect the termination resistor to the terminals Please take the power dissipated by the termination resistor into consid...

Page 12: ... valid for 3 of measuring range 6 1 30 6 1 30 6 1 30 6 1 30 6 1 30 6 1 5 30 6 1 5 30 6 1 5 30 6 1 5 30 6 1 5 50 6 1 5 30 A 20 1 1 mA 20 1 1 V 20 1 2 Transformer output F W Hz dB V V V mA 0 C A F W Hz dB V V V mA 0 C A F W Hz dB V V V mA 0 C A ...

Page 13: ...nder test as shown î Zero adjustment on the measuring ranges 300 W to 3 kW When measuring small resistance values on the 300W and 3kW range you can eliminate the resistance of the leads and transient resistances by zero adjustment î Connect the test leads to the meter and join the free ends î Briefly press the yellow multi function pushbutton 5 The meter acknowledges zero adjustment by sound signa...

Page 14: ...les monitor can also be used for the DOS version w A hard disk with 3 MB free storage space w A 3 5 disk driver fas disks with 1 4 MB storage capacity w A MICROSOFT compatible mouse If you wish to make hard copies w an EPSON compatible printer when using the DOS version w a printer supported by WINDOWS when using WINDOWS A F W Hz dB V V V mA 0 C 00000 A F W Hz dB V V V mA 0 C 0 6000 A F W Hz dB V ...

Page 15: ...the device under test is electrically dead External voltages would falsifythemeasuredresult ê Setthefunctionselectorswitch 6 to ê Connectthedeviceundertestasshown Forwarddirectionand orshortcircuit The meter displays the forward voltage in Volts As long as the voltage drop does not exceed the maximum display value of 3 0999 V you can also test several series connectedelementsorreferencediodeswiths...

Page 16: ...nt w bypressingtheyellowmulti functionpushbutton 5 foralongtime Themeter acknowledges this with the buzzer sounding twice The voltage measuring rangelastselectedismaintained w byoperatingthefunctionselectorswitch 6 13 Temperaturemeasurement With Pt 100 and Pt 1000 temperature sensors you can measure temperatures on 0 0 therangefrom 200 100 C 850 C 0 ê Setthefunctionswitch 6 to C ê Connectthesensor...