background image

Inner Range SIFER Smart Card Reader.   Installation Manual.

Revision 4.0     April.  2020.

Inner Range

SIFER Smart Card Reader

P/N: 994720 (Std) / 994720MF (Multi-format)

Features

-

Suitable for narrow door frames or mullions.

- Optical tamper device.
- Configurable RGB LEDs and Beeper.
- Multi-format version reads CSN or UID data from

other 13.56MHz formats.

 See Data Sheet.

- Connects to host Module via multi-drop RS485.
- Firmware updates over system wiring in Inner

Range systems.  

Latest firmware recommended.

Non-metallic mounting surface recommended.

See ‘Mounting Surface’ note on page 2.

FCC (North America)

This device complies with Part 15 of the FCC Rules and Innovation, Science and
Economic Development Canada’s license-exempt RSS(s). Operation is subject to
the following two conditions:
1. This device may not cause interference; and
2. This device must accept any interference, including interference that may

cause undesired operation of the device.

Class B product:

This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to
provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation.  If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off & on,
the user is encourage to try to correct the interference by one or more of the
following measures:

• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to

which the receiver is connected

• Consult the dealer or an experienced radio/TV technician for help

Warning:  Any changes or modifications not expressively approved by Inner Range
Pty Ltd could void the user's authority to operate this equipment

ISED Canada

L’émetteur/récepteur exempt de licence contenu dans le présent appareil est
conforme aux CNR d’Innovation, Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence. L’exploitation est autorisée
aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le

brouillage est susceptible d’en compromettre le fonctionnement.

CAN ICES-3 (B)/NMB-3(B)

Extending Cable

See “Preliminary Installation Notes 3 & 4” on page 2.

The pigtail cable can be extended with twisted-pair multistrand
data cable.  Pair 1 for Data A/B;  Pair 2 for V+/0V.  Shielded
cable provides additional noise immunity.  RS485/RS422 data
cable, balanced data cable and multistrand UTP cable are
recommended.  Specific recommendations are provided below.

READER POWER:  Remember to allow for voltage drop on V+/
0V over longer distances and/or when Readers are wired in a
daisy chain (multi-drop) configuration.  Supply voltage drop on
the cable is approx. 17mV per metre per Reader using 7/0.2
(24AWG) cable and assuming each Reader draws 100mA.

OVERALL SHIELD (

2

 Pair)

Tycab.  DPF4702 or DCK4702

Belden.  9842

Electra.  EAS7202P or EAS7302P

Garland.  MCP-2S

General Cable.  B2002CS

Alpha.  6413

Roadworx.  RW600224

Olex.  JD2PS485A

OVERALL SHIELD (

3

 Pair)

Belden.  9843

Tycab.  DPF6702

General Cable.  B2003CS

Garland.  MCP-3S

Electra.  EAS7203P

Electra.  EAS7303P

INDIVIDUALLY SHIELDED PAIRS (2 Pair)

Tycab.  DQQ47025

Garland.  MCP-2IS

Alpha.  2466C

Belden.  8723

UTP

Garland UTPL5EMTP (4 Pair stranded UTP patch cable)

If you have a requirement to use other cable types (e.g. short runs
of non-twisted cable), please contact Inner Range Technical
Support for advice.

Parts List

- Installation manual. (This document)
- Reader body with integrated pigtail cable.
- Mounting plate and Countersunk screw.

Specifications

Environment:

Operating Temp:      -35°C  to +65°C.
Ingress Protection:   IP67

Physical dimensions.

Height:  94 mm

Width:  40 mm

Depth:   16 mm  (26mm with Spacer)

Mounting plate.

91.5 mm (H) x 38 mm (W)

Power supply input:

11-14V DC <500mV ripple.

Current consumption:

75 - 100mA* typical.  150mA max.
*Depends on LED configuration.

V+/0V must only be connected to a power-limited circuit.

Maximum Cabling Distance using recommended cables.

Power (V+/0V).  @100mA* per Reader.

To 1 Reader using 2-Pair 7/0.2 cable: 100m.
To 1 Reader using 2-Pair 14/0.2 cable: 200m.
To 2 Readers using 3-Pair (2 pairs for +V/0V)

100m.

Data (Data A/Data B/0V).

Access Module to furthest Reader:

1000m.

Total data cabling on one “RDR RS485” Port:

1000m.

For longer cable runs &/or multiple Readers on the same run. One

of the following may be required:

-

Heavier duty 2-pair cable.

-

Additional pair or separate heavy duty fig. 8 for +V/0V.

-

A separate battery-backed local power supply.

See “READER POWER” below for more details.

Page 1

This manual is subject to change without notice.              www.innerrange.com.au

© 2014 - 2020.  Inner Range Pty. Ltd.

Doc. Part No:  634720

y

t

i

l

i

b

i

t

a

p

m

o

C

t

c

u

d

o

r

P

n

o

i

s

r

e

V

e

l

u

d

o

M

r

e

p

s

r

e

d

a

e

R

R

E

F

I

S

C

A

I

/

C

S

I

r

e

t

a

l

r

o

0

.

4

V

)

Y

L

N

O

C

A

I

(

6

1

M

A

L

I

r

e

t

a

l

r

o

0

.

2

V

6

1

M

A

L

S

r

e

t

a

l

r

o

0

.

2

V

4

e

r

a

w

t

f

o

S

i

t

i

r

g

e

t

n

I

r

e

t

a

l

r

o

0

.

4

V

a

/

n

r

e

ll

o

r

t

n

o

C

n

o

i

t

p

e

c

n

I

r

e

t

a

l

r

o

0

.

1

V

r

o

0

.

5

.

1

V

e

b

t

s

u

m

e

r

a

w

'

f

R

E

F

I

S

(

8

)

s

m

e

t

s

y

S

n

o

i

t

p

e

c

n

I

n

i

r

e

t

a

l

Optional Spacer for
metallic surface
P/N: 999033

UL Requirements (North America)

Refer to the Inner Range host LAN Module Installation manual for
details of UL regulatory requirements.

Reviews: