Sigma Technologies
Operation Manual
Page 1 of 3
3 Sequential Timer with Pressure Switch STPS 3000
A.
Programming the STPS 3000
1.
Use the Key provided for turning on the program “lock”. The Program mode is
indicated by a Program LED (Light Emitting Diode) turning on.
2.
Now that we are in program mode Use the Key called “Select” by pressing it and the
four LEDs on the right turn on and flash Sequentially.
3.
There are Four values to be programmed Timer 1 (Indicated by LED under Timer
Clock and Marked 1), Timer2, Timer3 and CCS.
4.
To program Timer 1 use select key to make the LED of Timer 1 Flash use Keys
marked “up” and “Down” to make display read value required then press
Start/Enter key to sore value in the Memory.
5.
Repeat same method for Timer 2, 3 and CCS.
6.
Verify Values stored by using select key to scroll the four settings.
7.
Turn the program key to turn off the program LED and remove key and place in
secure place now the settings are tamper proof.
5 5. 6
1 2 3 CCS
Up Down Start/Enter Reset
Lock
Program
Hold
Select