Quick Start Guide 

C-500 Series Gigabit Managed Switch 
 

1. 

Unpack the Switch and Check Contents

  

Part Number 

RJ-45 

Ports 

PoE 

Ports 

SFP+ 
Ports 

SC50010 

48 

48 

 

 Wall Mounting Kit

—two brackets and eight screws 

 

   Console Cable 

 

 

 

Warning and Cautionary Messages 

Warning

: This product does not contain any serviceable 

user parts. 

Warning

: Installation and removal of the unit must be carried 

out by qualified personnel only. 

Warning

: When connecting this device to a power outlet, 

connect the field ground lead on the tri-pole power plug to a 
valid earth ground line to prevent electrical hazards. 

Warning

: This switch uses lasers to transmit signals over 

fiber optic cable. The lasers are compliant with the 
requirements of a Class 1 Laser Product and are inherently 
eye safe in normal operation. However, you should never 
look directly at a transmit port when it is powered on. 

Warning

: When selecting a fiber SFP device, considering 

safety, please make sure that it can function at a 
temperature that is not less than the recommended 
maximum operational temperature of the product.  You must 
also use an approved Laser Class 1 SFP transceiver.  

Caution

: Wear an anti-static wrist strap or take other 

suitable measures to prevent electrostatic discharge when 
handling this equipment. 

Caution

: Do not plug a phone jack connector in the RJ-45 

port. This may damage this device. 

Caution

: Use only twisted-pair cables with RJ-45 connectors 

that conform to FCC standards. 

Caution

: Installing the switch in a rack requires two people: 

One should position the switch in the rack, while the other 
secures it using the mounting screws. 

Note

: The switch is an indoor device. If it is to be used with 

outdoor devices such as outdoor IP cameras or outdoor WiFi 
APs, then users are strongly suggested to install a surge 
protector or surge suppressor in order to protect the switch 
 

 

 

 

 

2. 

Mount the Switch

 

1.  Attach the mounting brackets to both sides of the 

chassis. Insert screws and tighten then with a 
screwdriver to secure the brackets. 

2.  Place the switch on a rack shelf in the rack. Push it in 

until the oval holes in the brackets align with the 
mounting holes in the rack posts. 

3.  Attach the brackets to the posts. Insert screws and 

tighten them. 

 
 
 
 

 
 
 
 
 

3. 

Ground the Switch

 

 

1.  Ensure the rack on which the switch is to be mounted 

is properly grounded and in compliance with ETSI ETS 
300253. Verify that there is a good electrical 
connection to the grounding point on the rack (no paint 
or isolating surface treatment). 

2.  Attach a lug (not provided) to a #12 AWG minimum 

grounding wire (not provided) and connect it to the 
grounding point on the switch rear panel. Then 
connect the other end of the wire to rack ground. 

 

 

 

 

 

Note: Other documentation, including the 
User Manual can be obtained from 

www.signamax.com

 

Caution: 

The earth connection must not be 

removed unless all supply connections have 
been disconnected. 

Caution:

 The device must be installed in a 

restricted access location. It should have a 
separate protective earthing terminal on the 
chassis that must be permanently 
connected to earth to adequately ground 
the chassis and protect the operator from 
electrical hazards. 

Caution: 

Installing the switch in a rack 

requires two people. One person should 
position the switch in the rack, while the 
other secures it using the rack screws. 

Note: 

The switch can also be installed on a 

desktop or shelf using the included adhesive 
rubber foot. 