background image

VALLONA RANGE HOOD INSTALLATION

IMPORTANT SAFETY INFORMATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
PERSONAL INJURY, PLEASE READ THE FOLLOWING:

Use the range hood only in the manner intended by the 
manufacturer. If you have questions, please contact Signa-
ture Hardware Customer Relations at 866-855-2284. 

Before servicing or cleaning the unit, power off the unit and 
switch off the unit’s circuit on the electrical panel. 

Installation and electrical wiring must be done by a qualified 

and licensed professional in accordance with all applicable 

codes, standards, and fire-rated constructions. 

Do not use the unit if any fans or electrical wiring are 

damaged. Contact Customer Relations or a qualified 

professional if any such issues arise. 

To prevent backdraft, sufficient air is needed for proper 

combustion. Gas from the fuel burning equipment needs to 

exhaust through the flue (chimney). Follow the heating 
equipment manufacturer’s guidelines and safety standards 
such as those published by the National Fire Protection 
Association (NFPA), the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), and 

the local code authorities. 

When cutting or drilling into walls or the ceiling, be aware of 
electrical wires, plumbing, and other utilities behind the wall. 

Ducted fans must always be vented outdoors.

CAUTION: 

For general ventilation use only. Do not use to 

exhaust hazardous or explosive materials and vapors.

CAUTION: 

To reduce the risk of fire and to properly 

exhaust air, be sure to duct air outside - DO NOT vent 
exhaust air into attics, crawl spaces, garages, or within walls 
or ceilings.  

1

Vallona Range Hood Installation Instructions

TO REDUCE THE RISK OF A STOVETOP GREASE FIRE, 
PLEASE READ THE FOLLOWING:

Never leave surface units unattended at high settings. 
Boil-over can cause smoke and grease to spill over which 
could ignite. Heat oils slowly on low or medium settings.

Always turn the range hood ON when cooking at high heat or 

when cooking foods that could flame. 

Clean venitlation fans frequently. Grease should not be 

allowed to accumulate on fans or filters.

Use proper pan sizes when cooking. Always use cookware 
appropriate for the size of the surface element.

TO REDUCE THE RISK OF INJURY, IN THE EVENT OF A 
STOVETOP GREASE FIRE, PLEASE READ THE FOLLOW-
ING:

SMOTHER FLAMES with a close-fitting lid, cookie sheet, or 
metal tray, then turn off the burner. BE CAREFUL TO 
PREVENT BURNS. If the flames do not go out immediately, 
EVACUATE AND CALL THE FIRE DEPARTMENT. 

Never pick up or handle a flaming pan.

DO NOT USE WATER, including wet dishcloths or towels. 
This could cause a violent steam explosion. 

Use an extinguisher ONLY if:

- Your fire extinguisher is a class ABC extinguisher, and you 

know how to operate it.

- The fire is small and contained in the area in which it 

started.

- The fire department has been called.
- You can fight the fire with your back to an exit.
   *Above based on “Kitchen Fire Safety Tips” published by the 
NFPA.

TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK, 
DO NOT USE RANGE HOOD WITH ANY SOLID-STATE 
SPEED CONTROL DEVICE.

Summary of Contents for VALLONA

Page 1: ... vapors CAUTION To reduce the risk of fire and to properly exhaust air be sure to duct air outside DO NOT vent exhaust air into attics crawl spaces garages or within walls or ceilings 1 Vallona Range Hood Installation Instructions TO REDUCE THE RISK OF A STOVETOP GREASE FIRE PLEASE READ THE FOLLOWING Never leave surface units unattended at high settings Boil over can cause smoke and grease to spill...

Page 2: ...ional for specific local requirements VENTING METHOD To vent through a wall a 90 degree elbow is needed If exhaust ducting with a diameter less than 5 91 150mm or if flat ducting is used the noise level of the range hood could increase and extraction will be less efficient IMPORTANT Observe all governing codes and ordinances It is the installer s responsibility to comply with installation clearances s...

Page 3: ... a carbon filter at the motor Fumes and vapors are recycled through the top grille DO NOT block the chimney holes CALCULATING VENT SYSTEM LENGTH To calculate the length of the system you need add the equivalent feet meters for all vent pieces used in the system 3 Vallona Range Hood Installation Instructions VENTILATION REQUIREMENTS cont d Wood Screws TOOLS AND MATERIALS Pencil Level Utility Knife D...

Page 4: ...2 to the outside vent using 6 diameter ducting If the existing outside vent contains a 5 opening a reduction fitting can be used Thread the upper chimney E to the inside of the lower chimney F Insert them vertically on of the range hood body fig 7 Affix the bracket Z fig 8 to the wall via the drill holes C Slide the upper chimney E towards the top locking it in with the appropriate screws in the drill ...

Page 5: ...E HOOD INSTALLATION 5 Vallona Range Hood Installation Instructions Fig 4 Ⓩ Ⓔ Ⓕ Ⓛ optional recirculating mode only Ⓨ Ⓜ Fig 2 A C B 8 21 32 10 5 64 10 29 32 7 7 8 11 13 16 23 5 8_27 9 16_35 7 16 Fig 3 1 3 2 3 4 Fig 1 ...

Page 6: ...VALLONA RANGE HOOD INSTALLATION 6 Vallona Range Hood Installation Instructions Fig 5 Fig 8 25 19 32 21 21 32 Fig 10 Fig 6 Fig 7 Fig 9 Ⓕ Ⓔ Ⓔ Ⓩ ...

Page 7: ...Make sure filters are completely dry before putting back into the range hood Reinstall the filter by making sure the spring release handles are toward the front Insert filter into upper track Push the spring release handle Push up on filter and release handle to latch into place CARE AND MAINTENENCE OPERATING INSTRUCTIONS Use the high suction speed in cases of heavy stove top cooking It is recommended...

Reviews: