background image

Momentum Collection

Chassis 5529 

Technical Instructions

1

Summary of Contents for Momentum Series

Page 1: ...Momentum Collection Chassis 5529 Technical Instructions 1...

Page 2: ...Glazing Momentum Optimal prescription base curve of 5 0 Silhouette plier with turquoise or purple tip BLS 58 97 98 for glazing...

Page 3: ...ion Momentum 2 Holding endpiece at the hinge bend the endpiece in the required direction to achieve proper inclination 1 Support lens mounting with mounting pliers This will prevent stress on the lens...

Page 4: ...4 Temple opening Momentum 1 Support lens mounting with mounting pliers 2 Apply pressure on hinge area with your thumb from inside...

Page 5: ...5 Temple closing Momentum 1 Support lens mounting with mounting pliers 2 Apply pressure at hinge area from the outside...

Page 6: ...nting tool from below to partially remove the pin from the pin cision hinge 2 Remove the pin with tweezer or pliers 3 Carefully remove the inner plastic part with a 1mm drill by carefully rotating the...

Page 7: ...e mounting Momentum 1 Partially insert the plastic sleeve into the temple from the top 2 Bring the temple and the hinge together and align holes Gently press the sleeve through with double padded flat...

Page 8: ...8 Temple mounting Momentum 1 Use tweezers or pliers to partially insert the titan pin into the sleeve from above 2 Press the pin into the hinge with double padded flat pliers...

Page 9: ...Momentum 1 Gently squeeze the forward part of the temple cover with a plastic tip plier to break the glue bond 2 Carefully pull off the temple cover 3 Shorten titanium wire with metal diagonal cutter...

Page 10: ...10 Temple shortening glued temple I Momentum 5 Remove remaining glue 6 Cut plastic temple cover to desired length with sharp blade to match the original angle...

Page 11: ...omentum 1 Test fit the temple cover on the shortened temple tip 2 Apply a small amount of glue e g Loctite 406 on the inside of the titanium wire 3 Slide the temple cover back onto the titanium wire a...

Page 12: ...12 Adjusting temple end Momentum 1 Adjust the temple to the ear shape with large curves 2 During temple end adjusting do not put pressure on the temple tip...

Page 13: ...bath for a maximum of 3 minutes per operation or with ethanol ethyl alcohol These methods will not damage the frame Avoid high temperatures like the car dashboard or saunas Always store your frame in...