background image

Titan Harmony  

Titan Sculpture   

Technical Instructions 

 

Summary of Contents for Titan Harmony

Page 1: ...Titan Harmony Titan Sculpture Technical Instructions...

Page 2: ...Inclination 1 Inclinate at the groove of the titanium side part Hold lens fixation firmly 2 Hold temple edge on both sides in the hinge area and adjust inclination angle Inclination groove...

Page 3: ...Temple Disassembly 1 Hold lens fixation firmly 2 Bend temple slightly and pull it out of the BLS Hinge should be totally straight Do not fold temple...

Page 4: ...Greasing the Hinge P0030 Grease inside loop of the hinge with a high precision lubricant If necessary clean hinge beforehand Mount disc hinge and assemble temple...

Page 5: ...Fixing the Disc Hinge Place the disc hinge form fit on both sides of the hinge loop NOTE The oval shape of the plug system ensures correct positioning BLS 89...

Page 6: ...Place temple aligned at the slot of the hinge and click it in carefully until it stops Temple Assembly...

Page 7: ...Hold lens fixation with pliers 4 Apply pressure on hinge from inside 1 Hold lens fixation with pliers 2 Press side parts firmly but controlled against the safe edge of a table Thumb should prevent pli...

Page 8: ...e Temple End 1 Loosen the glue with small back and forth movements at the edge of the temple end 2 Pull temple end off 3 Shortening of the temple end is not possible due to the form fit construction o...

Page 9: ...Temple Curving Adjustment Adjust temple curve behind the ear by bending temple ends Due to the metal needle inside the temple heating is not necessary...