background image

SmartIntego
PadLock AX

Manual

24.06.2021

Summary of Contents for SmartIntego PadLock AX

Page 1: ...SmartIntego PadLock AX Manual 24 06 2021 ...

Page 2: ...t specific safety instructions 6 3 Operation 7 4 Battery replacement 9 5 Signalling 14 6 Technical specifications 15 6 1 Scale drawings 16 7 EU UK Declaration of conformity 19 8 Help and other information 20 SmartIntego PadLock AX Manual Contents 2 21 ...

Page 3: ...an occur and access through a door can be blocked Modify the product only when needed and only in the manner described in the documentation Do not swallow battery Danger of burns from hazardous substances This product contains lithium button cell batteries Swallowing the button cell battery in can result in severe internal burns leading to death in as little as two hours 1 Keep new and used batter...

Page 4: ...sulting from aggressive cleaning agents The surface of this product may be damaged as a result of the use of unsuitable cleaning agents Only use cleaning agents that are suitable for plastic or metal surfaces Damage as a result of mechanical impact This product contains electronic components that may be damaged by mechanical impacts of any kind 1 Avoid touching the electronics 2 Avoid other mechan...

Page 5: ...ries at the same time Different times for G2 locks The internal time unit of the G2 locks has a technical tolerance of up to 15 minutes per year Qualifications required The installation and commissioning requires specialized knowledge Only trained personnel may install and commission the product Incorrect installation SimonsVoss Technologies GmbH accepts no liability for damage caused to doors or ...

Page 6: ...If you want to use the locking cylinder for outdoor applications or in high humidity bathrooms or washrooms use the WP version 2 Carefully insert the locking cylinder to avoid damaging the O rings Damage to the AX locking cylinder due to unsuitable tools Special tools are required to open the cover and dismantle the AX locking cylinder If you use un suitable tools you may damage the AX locking cyl...

Page 7: ...rn the knob fully clockwise 9 Shackle unlocked 3 Open the shackle 9 Padlock open Closing 1 Close the shackle 9 SL version Shackle locks into place automatically 2 ML version only Activate your identification medium on the knob SmartIntego PadLock AX Manual 3 Operation 7 21 ...

Page 8: ...3 ML version only Turn the knob fully counter clockwise 9 Shackle locked 4 Check for correct closure 9 Padlock locked SmartIntego PadLock AX Manual 3 Operation 8 21 ...

Page 9: ...ies with your hands 2 Use clean and grease free gloves Maintaining the condition during battery replacement The Digital Cylinder AX cannot engage or disengage without power supply Therefore while the batteries are removed the Digital Cylinder AX retains its current locking status and its data status programming and stored logs ü Special tool available 1 Align the thumb turn horizontally 2 Attach t...

Page 10: ...is parallel to the recess 4 Hold the special tool and knob cover firmly at the same time and turn them together 1 2 clockwise first and then counter clockwise 5 Remove the tool and cover SmartIntego PadLock AX Manual 4 Battery replacement 10 21 ...

Page 11: ...6 Push the latch inward and open the battery cover 7 Remove the batteries with the special magnetic tool SmartIntego PadLock AX Manual 4 Battery replacement 11 21 ...

Page 12: ... Close the battery cover 9 Cylinder signals the successful change with triple red flashing and beeping 10 Put on the cover NOTE Align the thumb urn cover and thumb turn using the triangles as shown in the graph SmartIntego PadLock AX Manual 4 Battery replacement 12 21 ...

Page 13: ...11 Turn the cover clockwise 9 The cover snaps into place with one click 12 Carry out a function test 9 Batteries are replaced SmartIntego PadLock AX Manual 4 Battery replacement 13 21 ...

Page 14: ...ion medium not author ised 1 briefly 1 long green Flip flop mode Engaged 1 long 1 briefly green Flip flop mode Disengaged 3 briefly after battery change red Successful battery change 8 briefly before engaging red Battery Warning Level 1 16 briefly before engaging red Battery Warning Level 2 SmartIntego PadLock AX Manual 5 Signalling 14 21 ...

Page 15: ...according to EN 12320 Weather protection IP67 Temperature range operation 25 C to 65 C according to DIN EN 15684 Battery type 2x CR2450 3V lithium Approved battery manufacturers Murata Panasonic Varta Battery lifetime Up to 12 years on standby or 100 000 activations Signalisation Audible signal buzzer and or visual signal LED green red Network capability Yes integrated LockNode can be ordered and ...

Page 16: ...ax transmission power BLE 2402 MHz 2480 MHz 2 5 mW Geographical restrictions within the EU No 6 1 Scale drawings 8 mm shackle 25 mm shackle interior height SmartIntego PadLock AX Manual 6 Technical specifications 16 21 ...

Page 17: ...8 mm shackle 60 mm shackle interior height SmartIntego PadLock AX Manual 6 Technical specifications 17 21 ...

Page 18: ...8 mm shackle 50 mm shackle interior height SmartIntego PadLock AX Manual 6 Technical specifications 18 21 ...

Page 19: ...ell as the corresponding UK statutory 2016 No 1091 EMC 2012 19 EU WEEE as well as the corresponding UK statutory 2013 3113 WEEE 2011 65 EU RoHS as well as the corresponding UK statutory 2012 No 3032 RoHS and regulation EG 1907 2006 EU REACH as well as the corresponding UK REACH The full text of the EU UK Declaration of conformity is available at the following internet address www simons voss com e...

Page 20: ...ion point for electronic waste as per European Directive 2012 19 EU Recycle defective or used batteries in line with European Directive 2006 66 EC Observe local regulations on separate disposal of batteries Take the packaging to an environmentally responsible recycling point Hotline Our hotline will be happy to help you landline costs depend on provider 49 0 89 99 228 333 Email You may prefer to s...

Page 21: ...ainable thinking and action and heartfelt appreciation of employees and partners With its headquar ters in Unterföhring near Munich and its production site in Osterfeld eastern Germany the company employs around 300 staff in eight countries SimonsVoss is a company in the ALLEGION Group a globally active network in the security sector Allegion is represented in around 130 countries worldwide www al...