background image

 

  1 

© Siqura 2012 

Version 1.5 (071708-1e) 
TETRA43x0TX&RX (MW07SP2) 

 

1.  General description 

 
TETRA 43x0 (4310 for multimode, and 4350 for single-
mode)  digital-optical  multiplexer/demultiplexer  systems 
can  transmit  signals  through  four  unidirectional, 
independent  composite  video  channels  and  two  audio, 
two  contact  closure,  four  data  channels,  and  Fast 
Ethernet,  all  bidirectional,  independent  and  transparent, 
using  one  single-mode  optical  fiber  per  system.  Video 
and  data/audio  input  signals  are  sampled  at  a  rate  of  15 
MHz and digitized with 10-bit accuracy. 
TETRA  43x0  TX  transceivers  convert  and  combine 
composite  video,  audio,  data,  contact  closure,  and 
Ethernet signals into one digital stream, which in turn is 
converted  into  an  optical  signal,  using  a  wavelength  of 
1310  nm.  The  TETRA  43x0  TX  will  also  convert  and 
decode  an  incoming  1550  nm  optical  signal  carrying  a 
digital stream of data, audio and contact closure signals. 
A  TETRA  43x0  RX  transceiver  receives,  converts  and 
decodes the video and other signals arriving through the 
optical  fiber.  It  will  also  convert  and  combine 
audio/data/contact  closure,  and  Ethernet  inputs,  then 
transmit  this  information  optically  towards  the 
complementary  TX,  using  an  optical  wavelength  of 
1550 nm. 

 

The composite video channels can all individually be set 
to  transparent  mode  (i.e.  video  clamping  off),  and  the 
video  channel  operation  mode  and  several  switching 
functions  are  accessible  through  software,  using  the 
SmartNet  management  system  (SNM).  Several  aspects 
of data and audio interfacing can be controlled by means 
of circuit board dip switches and jumpers. 

 

The  data  port  D1  and  D3  interfaces  can  be  set  for 
compatibility  with  RS-422,  RS-485  2W,  RS-485  4W, 
and Manchester PTZ (bi-phase) data.  In addition, using 
modified cabling, the RS-422 interface can be set up for 
digital current loop/TTY applications. Data ports D2 and 
D4 are set up for adjustment free RS-232 operation. 
The  inputs  of  the  4-wire  audio  interfaces  can  be  set  to 
high or low impedance, balanced or unbalanced. Contact 
closures are normally open. 

 

Front panel status LEDs indicate DC power good, video 
signal  presence,  local  and  remote  link  synchronization 
and data activity (see section 2). 
 
TETRA  43x0  units  are  double-width  (14TE)  Eurocard-
sized  modules  and  should  be  used  in  combination  with 
MC  11  or  similar  power  supply  cabinets,  the  EB-2 
versions of these cabinets offering SNM management. 

 

Figure  1.    Tetra  43X0  RX  front  Panel.  TX  panels  look 
similar, with video inputs instead of outputs. See table 

1. 

 
 
 

 

Stand-alone  models  (/SA  option,  see  supplementary 
/SA-2 manual) need separate 12 VDC power supplies. A 
Siqura PSA 12 DC-25 would be suitable. 

TETRA 43x0 

Four Channel Digital Video Multiplexer with Two-Way Audio, Data, and Ethernet 

 

USER MANUAL 

Summary of Contents for TETRA 4310

Page 1: ...l individually be set to transparent mode i e video clamping off and the video channel operation mode and several switching functions are accessible through software using the SmartNet management syst...

Page 2: ...t 100 Mbps Blinks with Activity 3 Configuration To access the internal set up switches for the audio data and Ethernet circuits remove the four screws on the front panel as indicated in figure 3 below...

Page 3: ...d towards V and the B input is biased towards V This bias ensures that the input line receiver interprets the state of the differential bus as a logical zero while all the drivers attached to the diff...

Page 4: ...es and connect suitable video and optical fiber equipment using appropriate cabling CLEAN THE OPTICAL FIBER CONNECTORS PRIOR TO INSERTION INTO THE OPTICAL PORT For long electrical links twisted pair w...

Page 5: ...0 to 20K Hz Sampling resolution 16 bit In output level 0 nom 9 max dBV SNR 77 dB Total harmonic distortion 0 25 at nominal level In output impedance 50 k or 600 in 50 out bal Data Number of channels 4...

Page 6: ...Before opening the equipment disconnect it from all power sources The equipment must be powered by a SELV power supply When this unit is operated in extremely elevated temperature conditions it is po...

Page 7: ...o fail EMC requirements Non video signal lines must use appropriate shielded CAT5 cabling S FTP or at least an equivalent If system components such as cabling e g coaxial cable data audio cc wiring an...