-4-
-5-
Alarm silence facility
When the smoke alarm has detected a smoke and turns into the alarm
mode, you can mute the alarm for a minimum of 5 minutes and a
maximum 15 minutes by pressing a button. After that the smoke alarm
automatically resets and returns into a normal operation mode. If there
are still particles of combustion in the air, the smoke alarm will turn into
the alarm mode again. WARNING: Before using the alarm silence facility,
always identify the cause of the alarm and make sure that the
circumstances are safe.
Low battery mode
When the battery is running low, the smoke alarm will indicate this with
a repetitive beep and flash for approximately 30 days. WARNING: This
smoke alarm is equipped with a non-replaceable battery. When this
warning occurs, replace the device as soon as possible! The acoustic low
battery warning signal can be muted for ten hours by pressing the test
button. The smoke alarm is still functioning and able to detect smoke
when it's in this mode.
Fault warning mode
When the smoke alarm is not functioning properly, it will turn into the
fault warning mode. Try cleaning the smoke alarm (see paragraph
maintenance) or replace the smoke alarm!
Maintenance
•
Test this smoke alarm weekly for correct function by using the test
facility. If the smoke alarm functions correctly, it will generate a loud
beep. Due to the loudness of the alarm, make sure that you always
stand at arm’s length distance from the unit when you are testing. If
the smoke alarm does not generate an acoustic signal, it must be
replaced immediately!
•
Clean the smoke alarm at least once per month to remove dirt, dust or
debris. Use a vacuum cleaner with a soft brush and vacuum all sides
and covers of the smoke alarm. Do not remove the top cover of the
smoke alarm to clean it inside.
•
Do not attempt to repair this smoke alarm. If the smoke alarm shows a
damage related to its functionality, it must be replaced!
•
Trouble shooting: False alarm is often caused by dust or steam.
Recycling and disposal
The WEEE symbol means that this product and its batteries
must be disposed separately from other household waste.
When they reach their end of life, take them to a designated
waste collection point in your area to guarantee a safe disposal or
recycling. Protect the environment, human health and natural resources!
www.china-siter.com
Overview LED & acoustic signaling
Operating mode
LED signal (flash)
Acoustic signal (beep)
Description mode
Normal
1 x per 40 seconds
None
Device is functioning properly
Test
1 x per second (3 x) /
pause of 1,5 seconds
1 x per second (3 x) /
pause of 1,5 seconds
Device is being tested
Alarm
1 x per second (3 x) /
pause of 1,5 seconds
1 x per second (3 x) /
pause of 1,5 seconds
Device has detected smoke
Alarm silence
1 x per 8 seconds
None
Smoke alarm is muted
Low battery
1 x per 40 seconds
(simultaneously with beep)
1 x per 40 seconds
(simultaneously with flash)
Battery is running low
Low battery silence
1 x per 40 seconds
None
Low battery warning is muted
Fault warning
1 x per 40 seconds
(alternating with beep)
1 x per 40 seconds
(alternating with flash)
Device is not functioning properly
Identification
Product type:
Smoke alarm Item
number:
PV522A
Supplier name:
Siterwell Electronics Co., Limited Supplier
address:
No.666 Qingfeng Road,
Jiangbei District, Ningbo, Zhejiang
Province, China, 315034
Website supplier:
www.china-siter.com
Importer:
Suomen Turvakauppa Oy, Kaarina,
Finland
16
DoP: PV522A-002
EN 14604:2005 + AC:2008
0333
Fire Safety
G 217022
SMOKE ALARM
PV522A USER MANUAL