U P S
12V / 7Ahx2
12V / 9Ahx2
1. Self-testing while switching on
Push the butten, the LCD display input & output voltage. then the UPS will
be ready for operation.
2. Silence Function
In Battery Mode, shortly press the switch will enable or disable the buzzer.
But when UPS is low battery or overloaded, the buzzer can not be silenced.
3. Autorun
In DC mode,UPS discharges till battery run out and cut off,UPS autorun
when AC recover.
4. Overload protection
When UPS is overloaded while operating, which is not solved by the user in
time, it will cut off the output automatically after some time.
5. Low battery shut off
When the battery is about to be exhausted, UPS will shut down automatically
to protect battery’s life.
6. Switching off
1) AC Normal
UPS will cut off the output and goes to AC standby mode by pressing the
switch for 3 seconds.
2) Backup
Press the switch for 3 seconds, the UPS will be turned off after a long beep.
TROUBLE SHOOTING
GUARANTEE CERTIFICATE
Customer's Name:
Contact Person:
Address:
Telephone No.:
Product/Model:
Fax No.:
Date of purchase:
Expire Date:
Dealer Signature:
Customer Signature:
Post Code:
Serial No.:
TROUBLE SHOOTING CHART
SYMPTOMS
UPS can not be turned
ON
POSSIBLE CAUSES
ACTIONS TO TAKE
UPS is not connecting
to AC and overloaded
The input fuse is burnt
or breaker is off
UPS suddenly turns to
battery mode in spite of
utility line present
Back-up time less than
1 minute
The buzzer beep every
1 second
Overloaded
The buzzer beeps every
8 seconds
Please connect to AC
and reduce the load
Replace the fuse or reset
the breaker, remove some
load and check if the load
is short-circuit or faulty
Please check the AC Input
voltage
Please send to the agency
to repair
Save the data promptly and
shut down the operating
system
Close the system and
recharge again
Please reduce the load
Recharge the battery for at-
least 12 hours and retest
the backup time
Please send to the agency
to repair
Charging unit fault
Battery is not fully
charged
AC Input voltage is too
low
The UPS is failure
Back-up time less than
specified
SPECIFICATIONS
The trouble shooting chart covers most of the difficulties that you may
encounter under normal working conditions. If the UPS fails to operate
properly, please review the following steps before calling the service
center.
1. Is the UPS plugged into a correct working outlet?
2. Is the line voltage within the rating specified?
3. Is the fuse or breaker / circuit protector on back panel open?
Please submit the following information when you call for service.
1. Model No. & Serial No.
2. Date of problem.
3. Full description of problem.
TEST THE UPS
To test UPS on battery back-up, switch off utility supply. Also your PC should
continue to function normally.
Input voltage
Output voltage
Output wave form
Output frequency
Battery rating
backup time
Noise level
Operating temperature
Humidity
Dimensions
Weight
350x120x188(mm)
145Vac~290Vac
195Vac~255Vac
PWM/DC
50Hz or 60Hz
3-20 minutes
Less than 45 dB
0~45 deg C
10 to 90% non condensing
LCD
-
1000
MODEL
Power in watts
720W
LCD
-
1500
LCD
-
1200
10.8kg 11.25kg 13.2kg
900W
700W