U P S

12V / 7Ahx2

12V / 9Ahx2

1. Self-testing while switching on

Push the butten, the LCD display input & output voltage. then the UPS will
be ready for operation.

2. Silence Function

In Battery Mode, shortly press the switch will enable or disable the buzzer.
But when UPS is low battery or overloaded, the buzzer can not be silenced.

3. Autorun

In DC mode,UPS discharges till battery run out and cut off,UPS autorun
when AC recover.

4. Overload protection

When UPS is overloaded while operating, which is not solved by the user in
time, it will cut off the output automatically after some time.

5. Low battery shut off

When the battery is about to be exhausted, UPS will shut down automatically
to protect battery’s life.

6. Switching off

1)  AC Normal

UPS will cut off the output and goes to AC standby mode by pressing the
switch for 3 seconds.

2)  Backup

Press the switch for 3 seconds, the UPS will be turned off after a long beep.

TROUBLE SHOOTING

GUARANTEE CERTIFICATE

Customer's Name:

Contact Person:

Address:

Telephone No.:

Product/Model:

Fax No.:

Date of purchase:

Expire Date:

Dealer Signature:

Customer Signature:

Post Code:

Serial No.:

TROUBLE SHOOTING CHART

SYMPTOMS

UPS can not be turned
ON

POSSIBLE CAUSES

ACTIONS TO TAKE

UPS is not connecting
to AC and overloaded

The input fuse is burnt
or breaker is off

UPS suddenly turns to
battery mode in spite of
utility line present

Back-up time less than
1 minute

The buzzer beep every
1 second

Overloaded

The buzzer beeps every
8 seconds

Please connect to AC
and reduce the load

Replace the fuse or reset
the breaker, remove some
load and check if the load
is short-circuit or faulty

Please check the AC Input

voltage
Please send to the agency

to repair

Save the data promptly and
shut  down  the  operating
system

Close  the  system  and
recharge again

Please reduce the load

Recharge the battery for at-
least 12 hours and retest
the backup time

Please send to the agency
to repair

Charging unit fault

Battery  is  not  fully

charged

AC Input voltage is too
low

The UPS is failure

Back-up time less than
specified

SPECIFICATIONS

The trouble shooting chart covers most of the difficulties that you may

encounter under normal working conditions. If the UPS fails to operate

properly, please review the following steps before calling the service

center.

1. Is the UPS plugged into a correct working outlet?

2. Is the line voltage within the rating specified?

3. Is the fuse or breaker / circuit protector on back panel open?

Please submit the following information when you call for service.

1. Model No. & Serial No.

2. Date of problem.

3. Full description of problem.

TEST THE UPS

To test UPS on battery back-up, switch off utility supply.  Also your PC should

continue to function normally.

Input voltage

Output voltage

Output wave form

Output frequency

Battery rating

backup time

Noise level

Operating temperature

Humidity

Dimensions

Weight

350x120x188(mm)

145Vac~290Vac

195Vac~255Vac

PWM/DC

50Hz or 60Hz

3-20 minutes

Less than 45 dB

0~45 deg C

10 to 90% non condensing

 LCD

-

1000

MODEL

Power in watts

720W  

 LCD

-

1500

 LCD

-

1200

10.8kg               11.25kg            13.2kg 

900W  

700W  