background image

PG Horizontal Series

1-1 & 2-1 Chillers & Freezers

User Manual

MAN10710 R

ev

. 2

.2 Mar. 

2018

SKOPE PEGASUS

PG200HC

PG500Prep

PG800Pizza

 

Summary of Contents for Pegasus PG100HC-2

Page 1: ...PG Horizontal Series 1 1 2 1 Chillers Freezers User Manual MAN10710 Rev 2 2 Mar 2018 SKOPE PEGASUS PG200HC PG500Prep PG800Pizza ...

Page 2: ...aland SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service Support We know you will get years of satisfaction from your new SKOPE product when you follow a few ...

Page 3: ...ice 11 Specifications 11 Drain 11 Electrical 12 Electronic Controller 12 Refrigeration Pipes and Solenoid 12 Installation Diagrams 12 3 Operation Automatic Start Up 14 Refrigeration Unit 14 Electronic Controller 14 HACCP 14 Pans and Lids 14 Electronic Controller 15 Controller Overview 16 Temperature Setpoint 16 Controller Alarms 17 4 Servicing Mains Isolation 18 Cleaning 19 Cabinet 19 Condenser Co...

Page 4: ...0HF 2 JH1303 1 1 freezer 3 Integral PG500HF JK1302 2 1 freezer 2 Integral PG100HFr 2 JH5301 1 1 freezer 1 Remote PG250HFr 2 JH5302 1 1 freezer 2 Remote PG400HFr 2 JH5303 1 1 freezer 3 Remote PG200HFr JK5301 2 1 freezer 1 Remote PG500HFr JK5302 2 1 freezer 2 Remote Model Part No Config Doors Refrigeration unit Operating temperature range PG250Prep 2 JH7302 1 1 chiller 2 Integral 1 C to 5 C up to 30...

Page 5: ...o touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard Ensure all necessary safety precautions are observed during installation or removal of the refrigerat...

Page 6: ... s to open fully Ensure the cabinet is positioned on a level surface so the door s shut and seal correctly and to prevent the condensate tray from overflowing Air movement above Prep and Pizza chillers must not exceed 0 3 m s Ventilation For efficient operation of the chiller it is essential that adequate ventilation be provided around the front of the refrigeration unit Normal operating condition...

Page 7: ...a set of adjustable height legs and a set of adjustable height castors Either of these sets can be fitted to the cabinet depending on specific height and manoeuvrability requirements The legs or castors should be fitted to the base of the cabinet before final positioning The adjustable legs screw into the castor mounting plates attached to the bottom of the cabinet The adjustable legs can adjust t...

Page 8: ...oduct to ensure even cooling and efficient operation of the chiller Do not allow products to overhang the front of the shelf as this could prevent the doors from shutting Leave an airspace of at least 75mm above product loaded on the top shelf Do not exceed a maximum loading of 20kg per shelf Remove some product if the shelves are flexing or bending 1 Unpack the shelving items from inside the cabi...

Page 9: ...o prevent finger jamming See over page for fitting instructions Model Doors Pans Lids Large Small Ambient PG250Prep 2 2 4 x 1 3 150mm deep refrigerated pans 2 PG400Prep 2 3 7 x 1 3 150mm deep refrigerated pans 1 2 PG550Prep 2 4 10 x 1 3 150mm deep refrigerated pans 2 2 PG500Prep 2 7 x 1 3 150mm deep refrigerated pans 1 2 PG800Prep 3 11 x 1 3 150mm deep refrigerated pans 3 1 Model Doors Pans Lids L...

Page 10: ... leaving the ends resting on one side of the cabinet top 2 Configure the lids as required with the notched ends meeting on the inside and slide the lower lids into the rails Orientation of the lids is important Ensure the notched ends meet on the inside to prevent finger jamming 3 Lower the rails and lower lids fully into the well so that they sit on the outside of the pan edges and place the rema...

Page 11: ...e rigid PVC pipe for the drain and ensure the drain has a minimum fall of 50mm per metre of drain length Model Refrig duty Max ambient temp Meanproduct temp Condensing temp Liquid temp Evaporating temp SST Operation basis PG100HCr 2 210 Watts 43 C 3 5 C 45 C 40 C 5 C 18 24 hours PG250HCr 2 360 Watts 43 C 3 5 C 45 C 40 C 5 C 18 24 hours PG400HCr 2 485 Watts 43 C 3 5 C 45 C 40 C 5 C 18 24 hours PG55...

Page 12: ...signal has been initiated and the symbol will indicate the evaporator fan is on Refrigeration Pipes and Solenoid A 1 4 liquid line and a 3 8 suction line are provided to attach pipes to The suction line must be insulated The electronic controller supplied with the cabinet can switch a solenoid No solenoid is supplied with the standard remote unit If a solenoid is fitted and controlled by the elect...

Page 13: ...Pegasus Horizontal 2 1 installation diagram Cabinet front Cabinet rear Refrig pipes 19mm drain tube Mains isolation box Service port bottom of refrigeration unit compartment 115 150 252 250 Side view Front view Bottom view Service port back of cabinet 141 50 32 ...

Page 14: ... will indicate the compressor is operating and the evaporator fan LED will normally come on within two minutes see Electronic Controller on page 15 for controller display To ensure efficient operation the electronic controller forces regular defrosts During the defrost cycle the compressor and condenser fan switch off and the evaporator fan stays on HACCP If Hazard Analysis Critical Control HACCP ...

Page 15: ...onds to initiate manual defrost To scroll settings down in program mode 5 Compressor ON when the compressor and condenser fan starts Flashes when activation of the compressor is temporarily delayed 6 Fan Shows when the fan is operational 7 Defrost ON when the defrost is activated Flashes when the activation of the defrost is temporarily delayed due to procedures in progress 8 Aux n a 9 Alarm Flash...

Page 16: ...aporator fan LED will normally come on within 2 minutes Open the unit door to access to electronic controller for programming Note On 2 1 cabinets the controller must also be unhooked from the unit door to access the buttons Temperature Setpoint The chiller temperature setpoint is factory set and can be adjusted if necessary SKOPE do not recommend that the setpoint be changed unless it is absolute...

Page 17: ...ashing Product LOW temperature alarm auto reset Flashing Refrigeration system high temperature pre warning auto reset 1 Clean the condenser coil see page 19 2 Check refrigeration ventilation Ensure clear airpath in front of the cabinet 3 Ensure the cabinet is installed in a suitable environment 4 To reset the CHt alarm unplug the cabinet from the power supply for 1 minute then reconnect to power s...

Page 18: ... isolating switch and unplugging the unit supply plug located inside the refrigeration unit compartment To isolate the chiller from the power supply 1 Open the unit cover 2 Switch off O the power at the isolation switch located on the LH side of the refrigeration cassette compartment and unplug the unit supply plug Unit cover Cabinet isolation switch Unit supply plug ...

Page 19: ...OPE to arrange for a SKOPE authorised service agent to clean the condenser with compressed air The condenser coil is located inside the refrigeration unit compartment and is accessed by opening the unit front cover Isolate the chiller from the power supply see previous page before cleaning the condenser coil Pans Air Diffusers Prep and Pizza cabinets only The food preparation pans and air diffuser...

Page 20: ... 2 1 cabinets are not fitted with interior lights To replace the interior LED light tube 1 Isolate the cabinet from the power supply see page 18 2 Remove the diffuser by squeezing it until it is released from the housing and then push the diffuser out of the way multiple door cabinet pictured for clarity 3 Rotate the LED tube until the pins on the ends of the tube align with the slots then slide i...

Page 21: ...ation unit 1 Open the unit cover and isolate the chiller from the power supply 2 Detach the electronic controller assembly from the unit cover by undoing the two fixing screws Place the electronic controller on top of the condenser duct 3 Remove the unit cover by lifting the bottom corner of the cover off the bottom hinge pin 4 Disconnect the cabinet supply ENSTO plug 5 Remove the top clamp screw ...

Page 22: ...ng adequate force to the right hand side of the wiring junction box to disengage the unit from the cabinet wall the unit will need to move over approximately 60mm 8 Carefully pull the refrigeration unit out from the unit compartment 9 When refitting the refrigeration unit Ensure that all seals are in good condition Refit the bottom clamp screw first before fitting the top clamp screw and ensure th...

Page 23: ...ntilation around the refrigeration unit Cabinet doors are opened excessively Keep door s open for minimum time 3 Product is too warm and spoiling Restricted cabinet airflow Ensure product is not blocking airflow slots and the product is no closer than 75mm from the cabinet top Temperature setpoint is too warm Adjust setpoint see page 16 4 Warm cabinet temperatures and or compressor operating for l...

Page 24: ... mark to the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Applies any other trade mark to the product Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations pa...

Reviews: