Skytech: 5320
REV. 7-25-18 Page 1
Model: 5320
INSTALLATION AND OPERATING INSTRUCTIONS
IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION
INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE
INTRODUCTION
This SKYTECH remote control system was developed to provide a safe, reliable, and user-friendly remote control system
for gas heating appliances. The system can be operated thermostatically or manually from the transmitter. The system
operates on radio frequencies (RF) within a 20-foot range using non-directional signals. The system operates one of
1,048,576 security codes that are programmed into the transmitter at the factory; the remote receiver’s code must be
matched to that of the transmitter prior to initial use. This is a dry contact switch designed for millivolt systems.
Review
COMMUNICATION SAFETY SECTION
under
TRANSMITTER
section and
THERMO SAFETY SECTION
under
REMOTE RECEIVER
section. These signal/temperature safety features shut down the fireplace system when a
potentially unsafe condition exists.
PM
ROOM
SET
TIMER
OFF
OFF
MODE/SET
BATTERY
COMPARTMENT
BACK
FRONT
The transmitter operates on (4) AAA-size 1.5V batteries. It
is recommended that ALKALINE batteries always be used
for
longer battery life and maximum operational
performance. IMPORTANT:
New or fully charged
batteries are essential for proper operation of the
multi-function transmitter. Insert (4) AAA size 1.5 V
batteries into the battery compartment on the back of the
transmitter, positioning the (+) and (-) ends of the batteries
as indicated on the casing. When the batteries are
inserted, the screen at right (with similar numbers) will
display.
PM
ROOM
SET
TIMER
OFF
OFF
AM
Note:
On initial start up if a LOW battery icon appears on the screen, check the position
of the batteries.
Note:
Due to the sensitive temperature-monitoring components in the transmitter, it
may be necessary to allow the transmitter to stabilize to room temperature before
accurate room temperatures are displayed on the screen. If the transmitter is
activated from a severe cold condition, it can take up to 15-minutes for accurate
temperature readings to appear.