SKY899
Installation Manual
009-11900-001
Installation Checkout - Page 3-1
Revision F
July 18, 2013
Section 3
Installation Checkout
3.1 INTRODUCTION
This section contains checkout procedures that will validate the installation and return to service of the
SKY899 installed with a WX-1000/SKY497 display using TT391 Flightline Tester. Detailed setup,
operation and maintenance information for the TT391 Flightline Tester is provided in the TT391
Instruction Manual.
CAUTION
Each time the TRC, directional antenna, or directional antenna cables
(including connectors) are installed, removed or replaced, the TRC must be
calibrated to the directional antenna (refer to paragraphs 3.3.2 & 4.4.3).
NOTES
1.
This procedure assumes familiarity with the set up and operation of the
TT391 Flightline Tester.
2.
All test equipment used in completing these tests shall be calibrated in
accordance with the manufacturer's recommendations.
3.
This section provides checkout information for the SKY899 using the
WX-1000 Display. If using an alternate display use Appendix F for
installation checkout.
4.
Checkout of the WX-1000 processor should be done in accordance
with the procedures detailed in the WX-1000 Installation Manual.
Table 3-1 lists the installation checkout procedures that should be used depending upon which display is
installed and which tester is being used.
Table 3-1: List of Installation Checkout Procedures
Display
Flightline Tester
Installation Checkout
Procedure
WX-1000 Display
TT-391
Section 3
TCAS-201
Appendix C
TIC T-49C
Appendix D
IFR-6000
Appendix G
Alternate Display
TT-391
Appendix F
TCAS-201
Appendix C
TIC T-49C
Appendix D
IFR-6000
Appendix G
The document reference is online, please check the correspondence between the online documentation and the printed version.