background image

NB40LP1

REV 01 – Nov. 2018 - ENGLISH

NUBI 4.0

Model:

NB40LP1

Power supply:

Lithium battery 3,6V

PIR:

yes

Thank you for purchasing NUBI 4.0, the intelligent smoke
screen security device able to be connected to any burglar
alarm system in new or existing systems.

OPERATIONAL OVERVIEW

The device is powered by a 3.6V AA size lithium battery
supplied   with   the   product,   such   as   SAFT   LS14500   or
similar. This battery provides the necessary energy to the
device for a period of 10 years. The ignition of the smoke
cartridge   is   ensured   even   when   the   battery  is   very   low
(2.2V)

NUBI 4.0 efficiently protects volumes up to 100 m

3

. The

smoke generated by NUBI 4.0 is based on incense and
does not produce toxic atmosphere as tested according to
the TLV-STEL directive EU 2017/164 and ACGIH. After use
the room must be ventilated before staying there.

NUBI 4.0 is activated through 3 inputs: one input drives the
immediate emission of smoke, while the other two inputs
realize a triple-consent logic to avoid false alarms. In this
case, to trigger the emission of smoke, it is necessary that
the state of the burglar system is armed, then within a time
window of 15 minutes two other conditions occur:
1) The burglar system goes into alarm
2) The integrated NUBI 4.0 PIR sensor detects movement
At the moment the second condition has been reach, the
smoke will be emitted immediately.
The inputs polarity and logic level can be easily configured
using the DIP switches in order to interface NUBI 4.0 with
any burglar panel.

NUBI   4.0   has   got   two   outputs   to   inform   other   devices
about  alarm  state  and  the battery low. The  output  logic
level can be reversed using DIP switches.

The box opening is detected with a tamper switch, its clean
contact can be connected to the burglar panel.

An optional internal siren can be housed inside the box
and plugged to the proper motherboard connector. In this
case the device must be powered by an auxiliary battery
pack, housed inside the NUBI box and plugged into the
appropriate connector.

The   smoke   cartridge   works   only   once,   the   smoke
emission, when triggered, can no longer be interrupted.
The smoke cartridge replacement is very easy, each spare
cartridge is provided with a special board soldered on its
wires   to   be   easily   plugged   on   the   proper   motherboard
connector.

INSTALLATION

NUBI 4.0 can be easily installed on the
wall   or   even   in   a   corner   at   a   height
between 150 and 250 cm.

WARNING

Do not insert any obstacle at a distance
of less than 1.5 meters from the smoke
outlet hole. 

The   best   performance   is   achieved   when
the jet of smoke coming out from NUBI 4.0
directly hits the floor, in this way the smoke
will cool and spread better.

After   opening   the   top   cover,   remove   the

motherboard to fix the lower part of the box on the wall.

1

Motherboard rails

2

Cabling wire buttonhole

3

Internal siren fixing spacers

4

Internal siren sound outlet hole

5

Device fixing holes

6

Smoke cartridge supports

Summary of Contents for NUBI 4.0 NB40LP1

Page 1: ...tely The inputs polarity and logic level can be easily configured using the DIP switches in order to interface NUBI 4 0 with any burglar panel NUBI 4 0 has got two outputs to inform other devices about alarm state and the battery low The output logic level can be reversed using DIP switches The box opening is detected with a tamper switch its clean contact can be connected to the burglar panel An ...

Page 2: ... the supply voltage must not exceed 3 6V INPUTS INTERFACE When the DIP Switches 1 4 are set to OFF NUBI inputs will become active when switched to GND as shown in the following table CSI Trigger the smoke delivery when the input is closed to GND SI Burglar system armed when the input is closed to GND disarmed when opened ALL Burglar alarm active when the input is closed to GND With the DIP SW1 the...

Page 3: ... detection the alarm confirmation will be due to the activation of the ALL input If the pre alarm was caused by the activation of the ALL input the confirmation will occur whit the PIR detection In test mode the smoke cartridge will never be activated and never the validation card will be damaged Remember to activate the operating mode DIP SW7 OFF at the end of testing SMOKE CARTRIDGE REPLACEMENT ...

Page 4: ...6V Autonomy About 10 years Size 12cm x 17cm x 14cm Saturable volume 100m3 Weight 760g Smoke average delivery time 25sec Operating temperature From 0 C to 45 C Storage temperature From 20 C to 55 C Maximum relative humidity 70 Inputs SI System state ALL Alarm CSI Immediate action Outputs 24H Tamper ALL Alarm BL Battery low ADVANCED WIRING The inputs interface mode can be programmed using the DIP sw...

Reviews: