background image

User Guide

RG-1000e Remote Gateway

June 2018

R2.2.2 v2

Summary of Contents for RG-1000e

Page 1: ...User Guide RG 1000e Remote Gateway June 2018 R2 2 2 v2 ...

Page 2: ...7 4 1 Conventional Mode 20 4 2 Capacity Plus legacy trunking network 21 4 3 Capacity Plus trunking network with NAI Data hybrid mode 23 4 4 Capacity Plus multi site trunking network with NAI Data hybrid mode 24 4 5 I O mode 26 4 6 Bridge mode 5 Storage and transportation conditions 27 6 Manufacturer warranty 28 28 6 1 What this warranty covers and for how long 28 6 2 General provisions 28 6 3 How ...

Page 3: ...ducts herein to improve usability function or design without prior notice Elcomplus does not assume any liability arising out of the application or use of any product nor does it cover any license under its patent rights nor the rights of others Trademarks MOTOROLA SOLUTIONS the Stylized M logo MOTOTRBO are registered in the US Patent Trademark Office SmartPTT and RG 1000e are the property of Elco...

Page 4: ... version July 2017 RG 1000e Remote Gateway R1 1 Updated release October 2017 RG 1000e Remote Gateway R2 0 Updated release Updated technical parameters February 2018 RG 1000e Remote Gateway R2 2 Updated release Updated technical parameters Added new operational mode June 2018 RG 1000e Remote Gateway R2 2 2 Updated release Radio connection cable schematics updated Delivery set info updated Operating...

Page 5: ...y not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This device complies with EN55032 CISPR32 EN55024 CISPR24 This device complies with DIRECTIVE 2011 65 EU RoHS 2 This device complies with IEC EN60950 1 This device complies with TR EAC 020 2011 Electromagnetic compatibility of technical means GOST CISPR...

Page 6: ... the MOTOTRBO equipment It is assumed that users responsible for setting up RG 1000e are familiar with the following The principles of building IP networks and radio networks using the MOTOTRBO equipment produced by Motorola and SmartPTT software developed by Elcomplus It is strongly recommended that you read this user guide you start work with the RG 1000e Note that improper testing operation mai...

Page 7: ...over the network The RG 1000e is an alternative to direct connection of control stations to the radioserver via a USB interface The RG 1000e with firmware version R2 2 or later may be used for connection of non Mototrbo radios to the SmartPTT radioserver Mobile radios and or repeaters analog or digital are connected to the RG 1000e using 5 wires PTT CSQ RX Audio TX Audio and GND This connection me...

Page 8: ...7 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 2 non MOTOTRBO control stations remote connection to SmartPTT dispatch system ...

Page 9: ...rs Direct Mode communication In conventional or trunking MOTOTRBO networks where direct IP connection to repeaters is unavailable In MOTOTRBO networks where connection to repeaters is established according to the hybrid scheme data calls are performed via the NAI interface of the repeater voice calls are performed via the control station In conventional or trunking non MOTOTRBO networks where the ...

Page 10: ...cy band of voice channel 20 3600 Hz VoIP codec 64 kbps G711 A Law Mu Law Transport protocol of control channel UDP and TCP Required bandwidth for control channel 15 kbps for each IP connection Transport protocol of voice channel UDP and RTP Required bandwidth for VoIP channel 128 kbps for each IP connection Time delay latency SmartPTT Radioserver RG 1000e ms Up to 1250 ms one way 2500 ms round tri...

Page 11: ... radio Radio1 socket and or radio Radio2 socket Power consumption 200 mA or less Design Dimensions 180x144x30 mm Ethernet connector RJ45 8P8C 8 pins Radio connector 3M 10126 jack 26 pins Power connector Phoenix Con PTSM 0 5 3 3 pins Audio connector Phoenix Con PTSM 0 5 2 2 pins Terminal connector USB mini B jack 4 pins Operating conditions Operating temperature range 4 to 140 F 20 to 60 C Relative...

Page 12: ...ew 4 pcs USB cable A miniB 1 m 1 pcs One interface cable is included in the RG 1000e delivery set for MOTOTORBO DM 4600e DM 4400e XiR M8600i DGM 8000e DGM 5000e radio families Optionally an additional interface cable can be purchased Interface cables for DM 2600 XiR M6660 XPR 2500 DEM 500 radios can be included in the delivery set on request Interface cables for non MOTORBO radios can be included ...

Page 13: ...escription LINK IP link status Flashing at intervals of 1000 milliseconds waiting for connection Constantly on IP connection is established RADIO Radio interface status Constantly on the interface is locked for one of the following reasons o The radio is not ready for example no power supply or the radio is turned off o Connection to IP channels is not established Flashing at intervals of 1 second...

Page 14: ...e network device is not established Green indicator is constantly on or flashing connection with a network device is established Yellow indicator is constantly on active duplex mode Yellow indicator is off half duplex mode is on AUDIO Socket for an external recorder RADIO 1 Socket for the first radio The pin numbering is provided in Appendix I RADIO 2 Socket for the second radio The pin numbering ...

Page 15: ...tandard radio bracket External parts must be mounted on the RG 1000e case with the screws from the delivery set only Longer screws may damage the board or its elements The allowed places for installing the mounting elements on the RG 1000e case are specified in Appendix II It is recommended that you adhere to the following sequence of connection and configuration procedures 1 Make sure the RG 1000...

Page 16: ...d to the RG 1000e the radio is the recommended power source The C DM4 radio connection cable contains the required wires If two MOTOTRBO radios are connected to the RG 1000e you may get power from both connected MOTOTRBO radios In this case it is strongly recommended to use a shared DC power supply for both connected MOTOTRBO radios 13 8 VDC power supply with 30A current load is sufficient for thi...

Page 17: ...00e using the interface cable 8 Connect the power cable and antenna to the radio 9 Connect the radio power cable to the RG 1000e power supply unit Attention The RG 1000e and the radios must be powered from the same power source If the power supplies are different connect their negative DC voltage leads together using the copper wire with a cross section area no less than 17 AWG 2 mm2 Attention Pay...

Page 18: ...17 4 1 Conventional Mode User Guide RG 1000e Remote Gateway R2 2 2 v2 4 Examples of using RG 1000e 4 1 Conventional Mode Fig 7 Coventional mode digital Fig 8 Conventional Mode digital analog ...

Page 19: ...18 4 1 Conventional Mode User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 9 Conventional Mode Repeater sample 1 Fig 10 Conventional Mode Repeater sample 2 ...

Page 20: ... TMS etc transmitting control commands to subscribers and voice message exchange In analog mode radios support only voice message exchange with subscribers Control stations can be programmed to operate on multiple channels They can switch to the required channel at the dispatch console command To transmit and receive subscriber voice calls control stations must belong to the same talkgroups as sub...

Page 21: ...ce calls both Group Calls and Private Calls and data received from subscribers to the radioserver over the IP network The radioserver transmits control commands and voice calls from dispatchers to subscribers via a pool of remote control stations in the given example it consists of 4 units connected to several RG 1000e s The number of remote control stations depends on the required number of simul...

Page 22: ...ion via the pool of the remote control stations The NAI DATA license must be installed on each repeater in the Capacity Plus network Data exchange between the radioserver and subscribers is carried out via the NAI protocol by means of the installed MNIS and DDMS services Group Calls and Private Calls are transmitted using a pool of control stations Each talkgroup that includes dispatchers requires...

Page 23: ...id mode User Guide RG 1000e Remote Gateway R2 2 2 v2 For more information on control station configuration in the Capacity Plus Hybrid mode see MOTOTRBO SYSTEM PLANNER the System Topologies chapter and the SmartPTT Radioserver Configurator software help file ...

Page 24: ... to that of the system connected to the Capacity Plus network in Hybrid Mode Remote control stations can be located in the radio coverage area of any of the network sites Fig 14 Capacity Plus Multi Site in Hybrid mode connection via the pool of the remote control stations For more information on control station configuration in the Linked Capacity Plus Hybrid mode see MOTOTRBO SYSTEM PLANNER the S...

Page 25: ...ital are connected to the RG 1000e using five wires PTT CSQ RX Audio TX Audio and GND This mode is called the I O Mode It provides voice exchange between SmartPTT dispatchers and talkgroups from the connected non MOTOTRBO radio networks The following figures show examples of using the RG 1000e with non MOTOTRBO remote control stations Fig 15 Motorola APX XTL radio connection to RG 1000e Fig 16 Mot...

Page 26: ...ion to RG 1000e If the connected control station does not an output CSQ COR TG Detect PL Detect signal line you can use the RG 1000e built in RX VOX for generating the CSQ signal For example this option is useful for connection of the MTM5000 family radios that are not equipped with the CSQ output signal line ...

Page 27: ... PTT CSQ RX Audio TX Audio and GND The Bridge Mode does not support any signaling systems CTCSS DQS MDC1200 QT Select V DMR dPMR and does not use digital links USB RS 232 to exchange commands with radios repeaters In Bridge Mode the RG 1000e s communicate with each other directly via IP networks creating transparent links for audio streams and PTT CSQ commands SmartPTT radioserver does not take pa...

Page 28: ...d gases The RG 1000e equipment can be shipped via any means of transport under the following conditions The air temperature is between 22ºF and 122ºF 30ºC and 50ºC The relative humidity is less than 95 at the temperature of 77º F 25ºC The equipment is protected from the direct precipitation and dust If the RG 1000e equipment is transported by air it must be put in a pressurized compartment It is p...

Page 29: ... which is attached to or used in connection with the RG 1000e or for operation of the RG 1000e with any ancillary equipment All such equipment is expressly excluded from this warranty Due to the fact that each system where the RG 1000e is used is unique Elcomplus disclaims liability for range coverage or operation of the system as a whole under this warranty 6 2 General provisions This warranty se...

Page 30: ...G 1000e of non Elcomplus supplied equipment which adversely affect performance of the RG 1000e or interfere with Elcomplus normal warranty inspection and testing of the RG 1000e to verify any warranty claim RG 1000e which has had the serial number removed or made illegible Freight costs to the repair depot RG 1000e which due to illegal or unauthorized alteration of the software firmware in the RG ...

Page 31: ...30 User Guide RG 1000e Remote Gateway R2 2 2 v2 Appendix I Pin numberings and diagrams of the interface cables Fig 20 RG 1000e MOTOTRBO XPR5 e DM4 e XiRM8 e DGM8 e connection cable schematic ver 1 ...

Page 32: ...31 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 21 RG 1000e MOTOTRBO XPR5 e DM4 e XiRM8 e DGM8 e connection cable schematic ver 0 ...

Page 33: ...32 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 22 RG 1000e XPR2500 DM2600 XiRM6660 DEM500 connection cable shematic ver 1 ...

Page 34: ...33 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 23 RG 1000e XPR2500 DM2600 XiRM6660 DEM500 connection cable shematic ver 0 ...

Page 35: ...34 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 24 RG 1000e TETRA MTM5 connection cable schematic ...

Page 36: ...35 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 25 RG 1000e APX XTL connection cable schematic ...

Page 37: ...36 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 26 RG 1000e CDM GM PRO connection cable schematic ...

Page 38: ...elements of the RG 1000e s and the radio bracket are shown in the following figure Fig 27 Mounting elements of the RG 1000e GATEWAYs and the radio bracket The mounting points of the RG 1000e brackets are shown in the following figure Fig 28 Mounting points of the RG 1000e GATEWAY brackets ...

Page 39: ...ble with wires in Red Black and Green Yellow colors On the 1st power cable end delete 35 40 mm outer insulation and delete 20 mm wires insulation This cable end will be used for connection to a power supply unit On the 2nd power cable end delete 10 12 mm outer insulation and delete 5 6 mm wires insulation Picture below shows power plug pin outs Fig 29 Power plug pin outs Connect Red wire to power ...

Page 40: ...39 User Guide RG 1000e Remote Gateway R2 2 2 v2 Fig 30 RG 1000e power plug conductors connect release ...

Reviews: