background image

 JMHZ-TF2Z397EN 

 

Page 1 of 2 

 

 

Instruction Manual    

Air Gripper for Collaborative Robots 

JMHZ2-20D-X7510

 

 

 
 
 
 
 
 
 
 
The intended use of this parallel type air gripper is to convert the potential 
energy provided by compressed air into a force which causes mechanical 
linear motion of the fingers.

 

1 Safety Instructions 

These  safety  instructions  are  intended  to  prevent  hazardous  situations 
and/or  equipment  damage.  These  instructions  indicate  the  level  of 
potential hazard with the labels of “Caution,” “Warning” or “Danger.” 
They are all important notes for safety and must be followed in addition 
to International  Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems.  

ISO 4413: Hydraulic fluid power - General rules relating to systems. 
IEC 60204-1: Safety of machinery - Electrical equipment of machines.        
(Part 1: General requirements) 
ISO  10218-1:  Robots  and  robotic  devices  -  Safety  requirements  for 
industrial robots - Part 1: Robots. 

  Refer  to  product  catalogue,  Operation  Manual  and  Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 
not avoided, could result in minor or moderate injury. 

 

Warning 

Warning indicates a hazard with a medium level of risk 
which, if not avoided, could result in death or serious injury. 

 

Danger 

Danger indicates a hazard with a high level of risk which, if 
not avoided, will result in death or serious injury. 

 Warning 

 

Always  ensure  compliance  with  relevant  safety  laws  and 
standards. 

  All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

2 Specifications 

2.1  Product Specifications 

Model 

JMHZ2-20D-X7510

 

Bore Size [mm] 

20 

Fluid 

Air 

Operating Pressure [MPa] 

0.1 to 0.7 

Ambient and Fluid Temperature [C] 

-10 to +50 

Repeatability [mm] 

± 0.01 

Maximum Operating Frequency [c.p.m.] 

120 

Lubrication 

Non-Lube 

Action 

Double Acting 

Gripping Force 
(/per finger) 

O.D. Force [N] 

54.2 

I.D. Force [N] 

72.2 

Opening/Closing Stroke [mm] 

14 

Weight [g] 

670 

Auto Switch Model 

D-M9P 

 

2.2  Individual Specifications 

2.2.1 Air Gripper 

Model 

JMHZ2-20D 

Bore Size [mm] 

20 

Fluid 

Air 

Operating Pressure [MPa] 

0.1 to 0.7 

2 Specifications - continued 

 

Ambient and Fluid Temperature [C] 

-10 to +60 

Repeatability [mm] 

± 0.01 

Maximum Operating Frequency [c.p.m.] 

120 

Lubrication 

Non-Lube 

Action 

Double Acting 

Holding Force 
(/per finger) 

O.D. Force [N] 

54.2 

I.D. Force [N] 

72.2 

Opening/Closing Stroke [mm] 

14 

Weight [g] 

244 

 

2.2.2

 

3-Port Solenoid Valve 

Model 

V114-5MOU 

Fluid 

Air 

Ambient and Fluid Temperature [C] 

-10 to +50 (No Freezing) 

Response time (DC) [ms] 

ON: 5 or less 
OFF: 4 or less 

Maximum Operating Frequency [Hz] 

20 

Lubrication 

Not Required 

Mounting Position 

Unrestricted 

Impact / Vibration Resistance [m/s2] 

150 / 30 

Enclosure Rating 

Dust proof 

Electrical Entry 

M-plug connector 

Coil Rated Voltage [V] 

24 

Allowable Voltage Fluctuation 

-10 to +10% 

Power Consumption [W] 

0.4[Starting 0.4, Hold. 0.1] 

Indicator LED 

LED 

 

 
2.2.3 Auto switch 

D-M9P(With indicator light) 
Auto switch model 

D-M9P 

Electrical entry direction 

In-line 

Wiring 

3-wire 

Output 

PNP type 

Applicable load 

IC circuit Relay PLC 

 

Power supply voltage 

5 , 12 , 24 VDC (4.5 to 28V) 

Current consumption 

10 mA or less 

Load voltage 

28 VDC or less 

Load current 

40 mA or less 

Internal voltage drop 

0.8 V or less at 10 mA (2 V or less at 40 mA) 

Current leakage 

100 

μ

A or less at 24 VDC 

Indicator LED 

Red LED illuminates when turned ON. 

Standard 

CE marking, RoHS 

 
 

3 Installation 

3.1  Installation 

 Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

  Install  and  operate the  product  only  after  reading  and  understanding 

its contents. 

  Allow sufficient space for maintenance and inspection. 

  Do not scratch or dent the air gripper by dropping or bumping it when 

mounting. Slight deformation can cause inaccuracies or a malfunction. 

  Tighten  the  screw  within  the  specified  torque  when  mounting  the 

attachment.  Tightening  with  a  torque  above  the  limit  can  cause 
malfunction, while insufficient torque can cause slippage and dropping. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

3  Installation - continued 

3.1.1 How to mount air gripper 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
Mount  the  master  plate  to  the  robot  arm  as  shown  in 

Figure  1

.  The 

hexagon socket head cap screws to a maximum tightening torque of 6.3 
N.m. 

  Mount the air gripper to the master plate as shown in 

Figure 2

. The 

hexagon socket head cap screws to a maximum tightening torque of 
3.0 N.m. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  Secure the connector as shown in 

Figure 3

  Do not energise the product while securing the connector. 

  Ensure that the connector is not loose. 

 

3.1.2 Sensing Position 

  The sensing position of the auto switch is fixed to the open end and 

closed end of the finger. 

  When detecting the gripping position of the workpiece, secure the auto 

switch  at  the  appropriate  position  according  to  the  shape  of  the 
workpiece.  

  For further details and example of setting the mounting position of the 

auto switch, please refer to the catalogue. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

 

 

3 Installation - continued 

3.1.3 Connector and Pin Layout 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

PIN 

Function 

Description 

Auto switch (Finger opening direction) 

Auto switch (Finger closing direction) 

NC 

Valve ON/OFF (Finger opening direction) 

Valve ON/OFF (Finger closing direction) 

                    - 

NC 

  - 

NC 

  - 

NC 

 

                          - 

NC 

10 

  - 

NC 

11 

+24V 

Power supply for 24VDC 

12 

GND 

Power supply for 0 VDC 

 

3.2  Environment 

 Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result in 

temperatures in excess of the product’s specifications. 

 

3.3  Piping 

 Caution 

  Before connecting piping make sure to clean up chips, cutting oil, dust 

etc. 

  When  installing  piping  or  fittings,  ensure  sealant  material  does  not 

enter inside the port. When using seal tape,  leave 1 thread

 

exposed 

on the end of the pipe/fitting.  

  Tighten fittings to the specified tightening torque. 

 

3.4  Lubrication 

 Caution 

  SMC products have been lubricated for life at manufacture, and do not 

require lubrication in service. 

  If a lubricant is used in the system, refer to catalogue for details. 

 
 
 
 

ORIGINAL INSTRUCTIONS 

 

 

 

 

 

Attached cable 

Figure 2 

Master plate 

Figure 1 

Detecting position 
of the open end of 
the finger 

Detecting position 
of the open end of 
the finger 

Figure 4 

A:(2:1) 

M12 12 pin connector(plug) 

A:(5:1) 

M8 8 pin connector(socket) 

Figure 3 

Reviews: