background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ControlTech

®

 

LINK Wireless 

ELECTRONIC 
TORQUE-ANGLE 
WRENCH 
 

20-3104-SO REV. B 

 

         

21-11

 

Summary of Contents for ControlTech CTLNK1R240

Page 1: ...ControlTech LINK Wireless ELECTRONIC TORQUE ANGLE WRENCH 20 3104 SO REV B 21 11 ...

Page 2: ...er use wrench with power off Always turn ON wrench so applied torque is being measured Do not press POWER while torque is applied or while wrench is in motion Never use this wrench to break fasteners loose Do not use extensions such as a pipe on handle of wrench Check that wrench capacity matches or exceeds each application before proceeding When using negative offsets verify maximum targets are n...

Page 3: ... receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference includ...

Page 4: ... 4 6 of reading 5 to 19 of full scale Dimensions Length Weight Drive Preset Range ANGLE 0 to 360 CW or CCW Display Resolution 1 TORQUE Display Range and Resolution as shown below Environmental Parameters Clause 1 4 of IEC610101 For use in Pollution Degree 2 Environments Altitude Up to 2000 meters Operating Temperature 0 F 130 F 18 C to 54 C Storage Temperature 0 F to 130 F 18 C to 54 C Measurement...

Page 5: ...eviously set target TORQUE or ANGLE screen will now be displayed depending on previous measurement mode selected 2 Select Measurement Mode Toggle between target TORQUE and ANGLE screens by repeatedly pressing ENTER button MODE COUNT AUDIBLE ALERT MODE SELECT AND MENU ENTRY BUTTON INCREMENT BUTTON ON OFF AND RE ZERO BUTTON DECREMENT BUTTON LCD BACKLIGHT AND PEAK TORQUE ANGLE RECALL BUTTON UNITS AND...

Page 6: ...surement press and hold BACKLIGHT button for approximately 3 seconds Peak TORQUE will flash for 5 seconds Angle Mode Note When angle measurement mode is selected for first time following a power on ANGLE ZERO REQUIRED message is displayed After two seconds angle zero process begins and wrench must be placed on a stable surface If ENTER button is pressed before two seconds to change to torque only ...

Page 7: ...rque and angle data CLEAR DATA Clears stored torque and angle data CYCLE COUNT Displays torque angle cycle count screen SETTINGS Displays advanced settings menu see Advanced Settings Section CONFIGURE Displays advanced configuration menu see Advanced Configuration Section 3 To select language menu press ENTER button while LANGUAGE is highlighted then highlight desired language and press ENTER butt...

Page 8: ...ET IN USE message will be displayed on target screen Note If UP DOWN buttons are pressed simultaneously while on Set Head Length screen displayed head length resets to zero or calibration head length for interchangeable head wrenches Note For a fixed length head head length entered is offset length measured from center of drive to center of fastener Note For an interchangeable head head length is ...

Page 9: ...ench Viewing Stored Torque and Angle Data Torque data is stored in memory after each torque cycle if applied torque has reached target value Torque and angle data is stored in memory after each angle cycle if applied angle has reached target value Memory Indicator is displayed when data is stored in non volatile memory 1 To view stored torque and angle data the CTECH will only store data while the...

Page 10: ... ALL DATA screen highlight YES menu selection to delete all stored data or NO menu selection to exit without deleting data 4 Press ENTER button after making selection Note If wrench is Locked see Preset Lock in Advanced section Clear Data function is disabled 00 M 100 0FT LB EXIT SET HEAD LENGTH SHOW DATA CLEAR DATA EXIT SET HEAD LENGTH SHOW DATA M CLEAR DATA LANGUAGE SET HEAD LENGTH SHOW DATA M C...

Page 11: ...settings each with a target minimum maximum over range and batch count value PSETs are stored in non volatile memory so that they are retained while power is off Note After adding a Preset see below navigate between manual target torque angle mode and PSET screen by repeatedly pressing ENTER button While PSET screen is displayed press UP DOWN buttons to select additional configured PSETs SET HEAD ...

Page 12: ...urn on Initial MAXIMUM TORQUE value will be TARGET TORQUE value plus positive torque tolerance default 4 see MODE SETUP in Advanced Configuration section Maximum torque value can be set greater than TARGET TORQUE value to 10 above wrench maximum range by pressing UP DOWN buttons Once desired maximum torque value has been set press ENTER button 7 BATCH COUNT screen is displayed next Default value i...

Page 13: ...DOWN buttons to increment decrement batch count Mode Count increments each time target angle is reached if a batch count of zero is entered Mode Count decrements if a non zero batch count is entered and resets to batch count value when count reaches zero Once desired batch count value has been set press ENTER button 7 PSET target screen is displayed labeled with next available PSET number from 01 ...

Page 14: ...onger available for selection Note Pressing ENTER button while EXIT menu selection is highlighted will exit without deleting PSET Note When a PSET is deleted all other stored PSET s will retain their original PSET numbers When a new PSET is entered it will be assigned first available PSET number in sequence 00 100 0 FT LB CHANGE PRESET DELETE EDIT EXIT UNIT button held Target Screen UP DOWN button...

Page 15: ...return to target torque or angle screen press ENTER button while EXIT menu selection is highlighted Note All user configurable settings are stored in non volatile memory and are retained while power is off Show Info Show Info menu selection displays wrench operational information 1 From Settings menu press ENTER button while SHOW INFO selection is highlighted 2 SHOW INFO screen is displayed 3 UP D...

Page 16: ...leep interval Selectable Intervals 2 MIN factory default 5 MIN 10 MIN 30 MIN 1 HR 2 HR 8 HR 4 Press ENTER button to accept selection and exit to Settings menu ENTER button SN 0412500366 CAL 2014 01 01 ISD 2014 01 01 TCF 14800 EXIT SHOW INFO SLEEP TIME LCD CONTRAST ENTER button VER 1 0 OVR CNT 0 TQZ 1539 ANZ 8196 UP DOWN buttons EXIT SHOW INFO SLEEP TIME LCD CONTRAST UP DOWN buttons ENTER button SL...

Page 17: ...to enable or disable audio feedback when a button is pressed 1 From Settings menu use UP DOWN buttons to highlight KEY BEEP selection then press ENTER button 2 KEY BEEP screen is displayed 3 Use UP DOWN buttons to highlight ENABLE factory default or DISABLE selection 4 Press ENTER button to accept selection and exit to Settings menu EXIT SHOW INFO SLEEP TIME LCD CONTRAST UP DOWN buttons ENTER butt...

Page 18: ...ain on until next BACKLIGHT button press 1 From Settings menu use UP DOWN buttons to highlight TOGGLE BACKLGHT selection then press ENTER button 2 TOGGLE BACKLGHT screen is displayed 3 Use UP DOWN buttons to highlight ENABLE or DISABLE factory default selection 4 Press ENTER button to accept selection and exit to Settings menu Note Backlight will turn off when wrench powers down either by POWER bu...

Page 19: ...ht VIBRATOR CONFIG selection then press ENTER button 2 VIBRATOR CONFIG screen is displayed 3 Use UP DOWN buttons to toggle ON or OFF selection 4 Press ENTER button to accept selection and exit to Settings menu EXIT SHOW INFO SLEEP TIME LCD CONTRAST UP DOWN buttons ENTER button VIBRATORCONFIG ON EXIT ENTER button UP DOWN buttons VIBRATORCONFIG OFF EXIT KEY BEEP AUTO BACKLIGHT TOGGLE BACKLGHT VIBRAT...

Page 20: ...ser configurable settings are stored in non volatile memory and are retained while power is off Mode Setup Mode setup menu allows user configure target torque and angle minus and plus tolerances and enable disable Torque THEN Angle mode and Torque AND angle mode 1 From Configure menu press ENTER button while MODE SETUP selection is highlighted 2 Mode Setup menu is displayed Menu Selections EXIT Ex...

Page 21: ...e initial maximum value when a Preset is first added Enable Disable Torque THEN Angle Mode This function will allow user to enable or disable Torque THEN Mode 1 From Mode Setup menu use UP DOWN buttons to highlight THEN DISABLED factory default selection then press ENTER button 2 TQ THEN ANGLE enable disable screen is displayed 3 Use UP DOWN buttons to select ENABLE or DISABLE selection 4 Press EN...

Page 22: ...and angle reach targets Note Red progress lights turn on if torque exceeds 110 of wrench full scale or if angle exceeds target plus tolerance while in manual mode Note Torque THEN Angle Presets are entered by pressing and holding Units button while on Torque THEN Angle screen MAXIMUM TORQUE defaults to full range plus 10 Refer to Adding a Torque Preset and Adding an Angle Preset in Basic section f...

Page 23: ... lights turn on if torque exceeds target plus tolerance or if angle exceeds target plus tolerance while in manual mode Note Red progress lights turn on if torque exceeds maximum torque or if angle exceeds maximum angle in Preset mode Preset Lock Report Mode Only Preset Lock function allows user to lock wrench so that only configured presets are accessible No other presets can be configured and man...

Page 24: ...ControlTech Calibration manual Delete Presets Delete Presets function allows user to delete all presets at once 1 From Configure menu use UP DOWN buttons to highlight DELETE PRESET selection then press ENTER button 2 Delete Presets confirmation screen is displayed 3 Use UP DOWN buttons to select YES or NO selection 4 Press ENTER button to accept selection and exit to Configure menu Note If Delete ...

Page 25: ...l time clock date and time for time stamping data records recording last calibration date and notifying user of an expired calibration interval Note When date and time is set for first time In Service date is also set and is used for calculating initial calibration interval see Setting Calibration Interval in Advanced Configuration section 1 From Configure menu use UP DOWN buttons to highlight SET...

Page 26: ... set calibration interval for when CAL NEEDED message will be displayed 1 From Configure menu use UP DOWN buttons to highlight SET CAL INTRVAL selection then press ENTER button 2 CAL INTERVAL screen is displayed 3 Use UP DOWN buttons to change calibration interval Selectable Intervals 12 MON factory default 6 MON 3 MON DISABLED 4 Press ENTER button to accept selection and exit to Configure menu EN...

Page 27: ...NEEDED message may be displayed Either disable calibration interval or enter a correct date Change Password Change Password function allows user to change password to a new password Default password is required to initially change password Refer to ControlTech Calibration Manual for default password 1 From Configure menu use UP DOWN buttons to highlight CHANGE PASSWD selection then press ENTER but...

Page 28: ... a J shank instrument has a default calibrated length of 2 500 inches The Control Box will round down to 2 499 inches and will be viewed as such on the Control Box Preset Set Headlength field after step 7 is performed 9 When adding a crows foot adapters or any other adapter type to an interchangeable head instrument that already has Snap on A suffix adapter attached the total combined effective le...

Page 29: ...mbined effective length of crows foot adapter and Snap on A J Y X and Z adapters must be inputted on the Parameter Control Box and or PC ControlTechManager SET HEADLENGTH field 4 When in Control Mode there is no rounding effect on the Control Box or ControlTechManager Set Headlength Fields See example in Figure 2 head offset reference 5 Standard ratcheting head instruments the set headlength calib...

Page 30: ... batteries soon Dead battery Press POWER button to turn off wrench and replace batteries Torque applied while zeroing Remove torque and re zero Wrench over torqued Recalibrate Wrench improperly calibrated Recalibrate Torque sensor failure Return to Factory Wrench moving during zeroing Place wrench on stable surface Gyro unstable Return to Factory ENTER button pressed during angle zeroing Aborted z...

Page 31: ...logy N I S T Torque parameters comply with ISO 6789 2003 and ASME B107 300 2010 B107 29 Note no U S or International Standards exist for angle wrenches MAINTENANCE SERVICE Clean wrench by wiping with a damp cloth DO NOT use solvents thinners or carburetor cleaners DO NOT immerse in anything Service and repairs are to be done by Snap on Service Centers only Contact your Snap on Tools representative...

Page 32: ...AA cells only Note When Replace Battery screen is displayed wrench will no longer operate until batteries are replaced Only POWER button functions which immediately turns off wrench Memory Indicators DATA IN MEMORY MEMORY FULL MEMORY ERROR Less than 1500 torque and angle records stored in memory 1500 torque or angle records stored in memory New records will not be recorded until memory is cleared ...

Page 33: ...This page intentionally left blank ...

Page 34: ......

Page 35: ......

Page 36: ...2 Singapore Repair Center Snap on Tools Singapore Pte Ltd 25 Tagore Lane 01 01 Singapore 787602 Phone 65 64515570 Fax 65 64515574 Japan Repair Center Snap on Tools Japan K K 2 1 6 Shinkiba Koto ku Tokyo 136 0082 Japan Phone 81 3 5463 1280 Fax 81 3 5463 1284 Snap on SUN De Mexico S A De C V Avenida Presidente Juarez No 2016 Col Los Reyes Zona Industrial Tlalnepantla Edo De Mexico CP54070 MEXICO Pho...

Reviews: