background image

EEDM504D

Digital Multimeter

Instruction Manual

Summary of Contents for EEDM504D

Page 1: ...EEDM504D Digital Multimeter Instruction Manual ...

Page 2: ... EEDM504D comes complete with the following accessories EEDM504D Instrument Zippered Vinyl Carrying Case Rubber Boot Test Lead Set Instruction Manual TABLE OF CONTENTS A INTRODUCTION 1 Congratulations 3 2 Product Description 3 3 EC Declaration of Conformity 4 B SAFETY CONSIDERATIONS 5 C TECHNICAL DATA 1 Features and Benefits 6 2 Product Applications 7 3 Specifications 8 10 D MEASUREMENT TECHNIQUES...

Page 3: ... parallel to the circuit Connect the test leads to a live circuit before setting up the instrument Touch any exposed metal part of the test lead assembly 4 3 EC Declaration of Conformity This is to certify that model EEDM504D conforms to the protection requirements of the council directive 89 336 EEC in the approximation of laws of the member states relating to Electromagnetic compatibility and 73...

Page 4: ...se auto range to select the appropri ate range 7 Year Covered by a standard 7 year warranty Warranty 2 Product Applications Perform the following tests and or measurements with the TPI EEDM504D and the appropriate function HVAC R FUNCTION DCmV Thermocouples in furnaces or gas applications ACA Heat anticipator current in thermostats ACV Line voltage ACV or DCV Control circuit voltage DCµA Flame saf...

Page 5: ...e voltage and current rated fuses Test Leads Use only correct type and overvoltage category rating d d ACA Range Resolution Accuracy Overload Protection 400µA 0 1µA Fuse 4000µA 1µA 1 2 5 digits 0 5Amp 600V 40mA 0 01mA 400mA 0 1mA 4A 0 001A 1 5 10 digits Fuse 10A 0 01A 10Amp 600V e OHM Resistance W Range Resolution Accuracy Overload Protection 400W 0 1W 1 0 5 digits 600V DC or 4kW 0 001kW AC Peak 4...

Page 6: ...04 F Storage Temp 10 to 50 C 14 to 122 F Relative Humidity 0 to 80 Power Supply 2 Each 1 5 Volt AA Batteries Battery Life 200 hrs Typical Size H x L x W 1 3in x 3 4in x 7 4in 33mm x 86mm x 187mm Weight 340g 12oz D MEASUREMENT TECHNIQUES 1 Controls and Functions a Push Buttons Activates manual ranging Hold in for 3 seconds to return to autorange Activates the Min Max mode APO Auto Power Off is disa...

Page 7: ...itch OFF Turns the EEDM504D off Function for measuring AC voltage ACV Function for measuring DC voltage DCV Function for measuring AC DC millivolts mV Funtion for measuring resistance diode testing and continuity buzzer 40 Function for measuring up to 40 DC micoamps uA Function for measuring up to 4000 AC DC microamps Function for measuring up to 400 AC DC milliamps Function for measuring up to 10...

Page 8: ...nal Functions b MEASURING AC VOLTS CAUTION Do not attempt to make a voltage measurement if a test lead is plugged in the A or µmA input jack Instrument damage and or personal injury may result WARNING Do not attempt to make a voltage measurement of more than 750V or of a voltage level that is unknown Instrument set up FUNCTION BLACK RED MINIMUM MAXIMUM TEST LEAD TEST LEAD READING READING COM VWHz ...

Page 9: ...est leads must be connected in series with the circuit WARNING Do not attempt to make a current measurement of circuits with more than 600V present Instrument damage and or personal injury may result Instrument set up FUNCTION BLACK RED MINIMUM MAXIMUM TEST LEAD TEST LEAD READING READING µA COM µAmA 0 1µA 4000µA mA COM µAmA 0 01mA 400mA 10A COM A 0 001A 10 00A Measurement Procedure 1 Disconnect po...

Page 10: ...nergized The only way to accurately test a diode is to remove it completely from the circuit before attempting to measure it Instrument set up FUNCTION BLACK RED MINIMUM MAXIMUM TEST LEAD TEST LEAD READING READING COM VWHz 0 001V 2 000V Measurement Procedure 1 Disconnect power to the circuit to be measured 2 Plug the black test lead into the COM input jack 3 Plug the red test lead into the VWHz in...

Page 11: ... not attempt to make a frequency measurement if a test lead is plugged in the A or µmA input jack Instrument damage and or personal injury may result WARNING Never attempt a frequency measurement with a voltage source reater than 600V Instrument set up FUNCTION BLACK RED MINIMUM MAXIMUM TEST LEAD TEST LEAD READING READING Hz COM VWHz 0 001Hz 10MHz Measurement Procedure 1 Disconnect power to the ci...

Page 12: ... RECORD MODE The record mode saves minimum MIN and maximum MAX values measured for a series of reading Activate the function as follows 1 Depress the REC button on the EEDM504D 2 The EEDM504D will immediately start to record MIN MAX values REC will be on the LCD to show record mode has been activated The reading on the LCD will be the actual reading The EEDM504D will give a confirmation beep every...

Page 13: ...isplay a battery symbol in the upper left corner of the LCD when the two internal 1 5 Volt AAA batteries need replacement Batteries are replaced as follows a Disconnect and remove all test leads from live circuits and from the EEDM504D b Remove EEDM504D from protective boot c Remove the three screws from the lower back of housing holding the compartment cover in place d Remove the compartment cove...

Page 14: ...27 26 Notes Notes ...

Page 15: ...h St Kenosha WI 53143 www snapon com ZEEDM504D User s Manual 2008 Printed in South Korea The information specifications and illustrations in this manual are based on the latest information available at the time of printing Snap on Tools Company LLC reserves the right to make changes at any time without notice ...