DATALOG H80/H81

for collecting energy data

EN

 

Instr

uctIon

 

manual

http://www.socomec.

com/datalogger

Summary of Contents for DATALOG H80

Page 1: ...DATALOG H80 H81 for collecting energy data EN Instruction manual http www socomec com datalogger ...

Page 2: ...nt of communication gateways 12 4 3 2 Adding devices to DATALOG H80 H81 13 4 3 3 Auto discovery of devices 13 4 3 4 Add a device 14 4 4 Declare data 17 4 4 1 Data configuration page 17 4 4 2 Selection of variables for the device concerned 18 4 4 3 Setting the properties of the variables for the following types Measuring Meter Index 18 4 4 4 Setting the properties of the variables for the following...

Page 3: ... H80 H81 via the available interfaces HDMI interfaces USB 2 0 and USB 3 0 User can directly connect their devices screen keyboard mouse as indicated in the Quick Start guide to the web server of DATALOG H80 H81 via the browser on a workstation connected to the network Here is the list of compatible browsers Internet Explorer v9 and higher Firefox v24 and higher Chrome v30 and higher We recommend t...

Page 4: ... Supplied with AC DC adaptor for Europe Includes RAM 4GB DDR3L FLASH CFAST 32 GB MLC type Top 40 to 85 C card LICENCE and OS MICROSOFT WES7 installed RAILDIN 9741640401 mount The DATALOG H80 is guaranteed for 1 year Detailed description of the H81 Mini Fanless Industrial PC Intel Atom CPU with dual core N2807 1 58 GHz processor CFAST slot 1 x RS232 1 x USB3 0 2 x USB2 0 HDMI output 2 x GbeLAN Vin ...

Page 5: ...ous external devices for the operation of certain services FTP HTTP servers for the publication of data stored in DATALOG H80 H81 and the backup of alarm and log files as well as a configuration backup SMTP server for sending activity reports by e mail The diagram below shows the standard communication architecture ...

Page 6: ...1 5 1 ANA 110000 0 ANA CLIM local therm Gateway 172 23 24 100 Voltage L1 None None 1 V 5 1 110000 Index Key Date Value Quality 0 2017 01 19T15 40 42 3 039 192 1 2017 01 19T15 40 42 3 169 192 2 2017 01 19T15 40 42 2 403 192 3 2017 01 19T15 40 42 232 1 192 4 2017 01 19T15 40 42 232 81 192 5 2017 01 19T15 40 42 232 13 192 0 2017 01 19T15 41 42 3 036 192 1 2017 01 19T15 41 42 3 256 192 2 2017 01 19T15...

Page 7: ...ection can be activated automatically To access the configuration menu of the Windows services the user can use the script Remote Desktop Connection Access the MSTSC exe script on your computer Enter the URL of DATALOG H81 Use the Windows account Account admin Password To find out the password contact your advisor at Socomec Once connected to DATALOG H81 Access the Control Panel section in the Sta...

Page 8: ...8 EN DATALOGGER H80 81 546 226 A SOCOMEC Then access the Administrative Tools section Then access Services Finally access the Socomec Network Connection Service ...

Page 9: ...TALOG H80 H81 To access the configuration of DATALOG H80 H81 the user has several ways 1 By directly connecting a keyboard and screen to DATALOG H80 H81 then by clicking on the icon 2 By accessing the Remote Desktop Connection script see Chapter 3 5 and then clicking on the icon 3 Via a web browser enter the URL of DATALOG H80 H81 ...

Page 10: ...so the different functions of collecting storing and publishing data can be used Below are the details of the various possible configuration options 4 1 Identification To accessing the configuration interface the user requires a password To find out the password contact your advisor at Socomec ...

Page 11: ...OG H80 H81 identification messaging server remote server 8 Activity report tab Configuration function for publication of the Activity report 9 Options tab Feature to apply full configuration of DATALOG H80 H81 Projects menu 10 Read configuration tab Function to read and change the active configuration in DATALOG H80 H81 11 Apply configuration tab Function to apply the configuration to DATALOG H80 ...

Page 12: ...aring devices in the Device tab allows the user to create configure and delete the communication gateways and measuring devices that he wishes to manage in DATALOG H80 H81 4 3 1 Management of communication gateways The home page of the Devices tab allows the user to view and manage all gateways seen by DATALOG H80 H81 From this page the user can General tab Change the name and the description of t...

Page 13: ... allows users to auto discover devices connected to DATALOG H80 H81 New device New devices compared with current configuration Modified device Existing devices in the current configuration but with some changed settings Device in conflict Device for which the configuration conflicts with others example same IP address for gateways Device not found Devices not found at the launch of the auto discov...

Page 14: ...ption Give a brief description optional Location Indicate the location of the device in the hierarchy or its geographical location optional Type Select the type of device in the proposed list Socomec device or a generic mode in Modbus or SNMP for the products of other brands Communication for devices connected in Modbus mode the user must specify the communication mode Connection select the connec...

Page 15: ...the device Software port 161 SNMP read only community Enter the password for read access to the SNMP server SNMP write only community Enter the password for write access to the SNMP server SNMP version State the SNMP version 1 2 or 3 Profiles The user can select a profile Energy Efficiency Power Monitoring Power Quality from pre selected variables associated with the device These settings can be c...

Page 16: ...16 EN DATALOGGER H80 81 546 226 A SOCOMEC Delete the device Duplicate the device Duplicate the device with its variables Rename the device ...

Page 17: ... levels p History of positive reactive power levels Q History of negative reactive power levels Q History of apparent power levels S Power Monitoring Frequency Active power total Phase 1 power factor Phase 2 power factor Phase 3 power factor Power Factor total Power Quality Total harmonic distortion of currents THD I1 THD I2 THDI3 THD IN Total harmonic distortion of voltages between phases THD U12...

Page 18: ... the list 4 4 4 3 Setting the properties of the variables for the following types Measuring Meter Index The properties of the variable selected from the list 2 are editable in the sidebar 4 For each variable the user can set In the General tab Name A variable can be renamed Unit The variable can be changed Fluid For pulse meters specify the fluid Usage A usage can be associated from a predefined l...

Page 19: ... the sidebar 4 For each variable the user can set In the General tab Name A variable can be renamed Input State the device input Deactivated A set variable can be manually deactivated In the Data acquisition tab Device Setting can only be edited in the Device tab Data This setting cannot be modified Data polling The data collection period for the variable can be set steps of 10 minimum ...

Page 20: ...s to filled in differ according to the type of alarm In the example shown here the alarm is an On threshold type and the following fields must be filled in Value of the threshold Indicate the threshold that will trigger the alarm Hysteresis in State whether this alarm is subject to a hysteresis phenomenon Triggered if State whether it is a high threshold or a low threshold In the Data acquisition ...

Page 21: ... will send its activity reports User Name Choose a login only if sent via port 587 Password Choose a password only if sent via port 587 Secure communication Activate an encrypted session between DATALOG H80 H81 and the server In the Set remote server section Select server To send files data configuration log to a remote server the user can select an HTTP server or an FTP server Destination folder ...

Page 22: ...data specifies whether he wants a single file for all devices or a file for each device Send files defines how often reports should be sent every X minutes or on a specific day at a specific time of the week by default the report frequency is disabled set to never 4 6 Configure the activity report To monitor DATALOG H80 H81 operations the user can configure the sending of a periodic activity repor...

Page 23: ... and time of the week by default the frequency with which reports are to be sent is disabled set to never stating thee mail address of the recipients the user can enter multiple e mail destination addresses for the activity report The e mail received by the recipients consists of a summary in the body of the e mail an attachment with the summary and details of the faults identified ...

Page 24: ...type of configuration is faster than a full configuration particularly when a very large number of devices several hundred are connected to DATALOG H80 H81 2 full update of the configuration of DATALOG H80 H81 configuration of the DATALOG H80 H8 settings as well as the configuration of the devices and associated variable properties Applying this type of configuration is longer than a limited confi...

Page 25: ...25 EN DATALOGGER H80 81 546 226 A SOCOMEC ...

Page 26: ...546 226 A EN 04 17 Non contractual document 2017 Socomec SAS All rights reserved CORPORATE HQ CONTACT SOCOMEC SAS 1 4 RUE DE WESTHOUSE 67235 BENFELD FRANCE www socomec com ...

Reviews: