background image

English

16

optimize!

www.

.com

information@itm.com

1.800.561.8187

Summary of Contents for WireXpert 500

Page 1: ...English 16 optimize www com information itm co 800 561 8187...

Page 2: ...1 Quick Start Guide v7 2 build 424 WX 4500 500 Copper Test Adapters Kit optimize www com information itm co 800 561 8187...

Page 3: ...One touch Buttons USB Device Port Mic Headphone Port Stylus Hands free Stand KIT CONTENTS WireXpert LOCAL REMOTE Headsets CAT6A Channel Adapters 12V DC Power CAT6A Permanent Link Adapters Carrying ca...

Page 4: ...touch access buttons Main functional buttons AUTOTEST SETUP DATA and TOOLS for WireXpert Enables quick AUTO TEST and results viewing in a single click Stylus Provides precise selection on LCD touch sc...

Page 5: ...re 2 Insert USB flash drive to WireXpert units 3 Wait for upgrade option prompt 4 Or go to System Settings Settings 2 Storage USB icon Upgrade Firmware Exporting and importing files 1 Insert USB flash...

Page 6: ...g Select LIST BASED TESTING for pre configured labels created with eXport PC software AutoSave Enable option for WireXpert to auto save every PASS result Option will be enabled for List Based Testing...

Page 7: ...or AUTOTEST Selecting Cable and Connector Manufacturer Go to Test Settings Cable or Connector to specify manufacturer Select Generic Unshielded or Generic Shielded if manufacturer is unknown Select Cu...

Page 8: ...t is necessary to perform a set reference measurement if the LOCAL and REMOTE units are being paired for the first time If there is a mismatch in firmware versions or a set reference has not been perf...

Page 9: ...ummary result of the two worst values will be displayed after an AUTOTEST Select the View button on AUTOTEST summary screen to view detailed results Select parameter to view plot or detailed result AU...

Page 10: ...d manually Note Green PASS Good test result in accordance to pre defined settings Green PASS PASS result with one or more test parameters that have margin in the range of uncertainty of the tester Red...

Page 11: ...ed Results Press the DATA button to view saved results Select Copper to view saved copper test results Fiber and MPO saved results can be viewed when respective adapters are connected to WireXpert DAT...

Page 12: ...er and press the View button 3 Press the Manage button 4 Select result s and press the Delete to delete result s Renaming a saved result 1 Press the DATA button 2 Select Copper or Fiber and press the...

Page 13: ...e for importing from USB flash drives or click Import From PC for importing from local hard drives 4 To view detailed results double click on the cable label and a new window with comprehensive result...

Page 14: ...ults select and right click on test results to perform operation on Replace Cable Label to replace text in labels of the selected cables Replace Operator Name to replace text in names on the selected...

Page 15: ...te testing when conducting in non sequential orders To create label list 1 Launch eXport and go to Tools Label List Generator 2 Enter the first and last label of each tier into the respective fields 3...

Page 16: ...ings Label Source 5 Select List Based Testing and select the label that has just been imported 6 Press the AUTOTEST button to view list and select label for test A PASS or FAIL result will be indicate...

Reviews: