Plug SVS unit into the 
mains. Ensure SVS unit is 
switched off.

1

0

I

Plug your appliance into the 
SVS unit. Do not switch on.

2

0

I

Turn on the SVS unit. 

3

On / Off switch

0

I

Turn on the appliance. 
The SVS unit is now ready 
to use (after a short delay).

4

The SollaTek  volTage STabiliSer SvS04-22

Microprocessor controlled Stabiliser

INSTRUCTION MANUAL

• Before using the SVS please read all instructions carefully. 

•  Keep these instructions for future reference. 

Safety

•  All equipment designed and manufactured by Sollatek (UK) Ltd complies with the latest safety codes of practice. You should still follow all safety instructions and use  

 

caution when installing and operating electrical equipment.

•  To avoid the risk of shock, DO NOT expose this equipment  to rain, moisture or liquid spillage.

•  Before attempting to use the SVS (Sollatek Voltage Stabiliser) ensure that the total loading of your equipment does not exceed the maximum rating of the SVS.   

 

To check the rating of your SVS, refer to the label on the back of the unit.

•  Do not attempt to dismantle the SVS, to do so will invalidate the guarantee. There are no user serviceable parts inside.

Description

As both high and low mains voltage can damage your electrical equipment, the Sollatek SVS is designed to monitor and correct the incoming  supply continuously.

If the voltage rises or drops, the SVS will stabilise the output to ensure that the voltage reaching your equipment remains constant at 230V (±6%) , within the operating 

range of the unit.

The Sollatek SVS has a modern state of the art 7 LED display to indicate accurately the state of the input at all times and 5 LEDs to indicate the output voltage supplied to 

your load.

The Sollatek SVS is unique in having a built-in Sollatek AVS™  (Automatic Voltage Switcher). This adds the following protective functions;

a) Provides a start-up delay which prevents rapid switching ON and OFF of the appliance in serious fluctuations. This is especially important for loads that use 

compressors (e.g. Fridges, Freezers, Coolers, Air conditioners) and vital for sensitive electronic equipment like computers, photocopiers, fax machines, lab equipment, 

medical instruments etc. 

b) Provides a shutdown and disconnect function whereby it will disconnect switch off your equipment in cases where the fluctuations are extremely BAD and the SVS 

can not safely correct the voltage.

c) The Sollatek SVS has a built-in microprocessor which adds the advanced feature TimeSave™. TimeSave™ means that when the mains return to normal from a 

brown-out, the SVS checks the duration of the OFF time. 

The SVS  also protects your electrical equipment against power spikes and surges. By using the SVS you will ensure a stable, and clean voltage supply to your equipment. 

The SVS04-22 is designed for usage with fridges, freezers, coolers and vending machines rated up to 4Amps.

Specifications

 

Model  

SVS04-22

  Output Current  

4Amps 

  VA@230V 

920V

  VA@240V 

960V

  Weight  

3.6kg 

  Case type   

Plastic 

  AVS function  

YES

  Spike protection  

YES

  Dimension unpacked(mm)  

190 x 100 x 124

  Dimension packed(mm)  

240 x 178 x 150

Input/output range

  Input range 

 -26% to +19%.

  Output accuracy 

± 6%.

  Frequency range 

45Hz to 75Hz.

  Regulator range @ 230V  

171-274V ±6%   (For input voltage beyond this range, output accuracy is +-10%.  

 

 

 

  Regulator range @ 115V  

86 -137V ±6%  (For input voltage beyond this range, output accuracy is +-10%. 

General 

  Derating factor  

10% to 15% per 10°C above 40°C.

  Synchronization 

Output synchronized to input.

  Permissible overload 

1000% for 100ms,  

     

150% for 4 minutes,  

     

110% for 15 minutes.

  Load types  

Suitable for fridges, freezers, coolers and vending machines rated up to 4A. 

  Technology 

Transformer tap switching using relay based.

  Efficiency  

>97%  (at 100%  linear load).

  Control 

Microcontroller based control system provides self checks, system integrity monitoring and  

     

diagnostic indicators.

  Control protection 

Internal surge arrestors and filters in control circuit protect against disturbances. Filtering  

     

algorithms and fault tolerant software protect against disturbances and false measurements.

  Ambient temperature range  

0 to +55ºC.             

  Relative humidity  

<95%, non condensing.

  Acoustic noise 

< 45 dB (A).

  Expected service life  

> 10 years.

  Standards 

Manufactured to comply with :- ISO9001:2000, CE, EN 50081-1:1992, EN 50082-1:1998,  

     

EN 55022:1998, EN 61000-4-2:1995/1998, EN 61000-4-3:1996, EN 61000-4-4:1995,  

     

EN 61000-4-5:1995, EN 61000-4-6:1996, EN 61000-4-11:1994, DD ENV 50204, BS EN 61558-1, 

     

EN 60065,  EN 60555.

  Correction speed 

750 Volts per sec.

  Response   

Within 0.1 second .

  kVA rating  

The Sollatek SVS range is wide and covers units from 480VA to 18kVA in single phase and 13kVA to 52kVA in three phase. 

  Efficiency   

88% at 25% load, 94% at 50% load, 96% at 75% load, 97% at 100% load.

  Power factors  

Unaffected by  load power factor.

  AVS™ function 

Automatic voltage switcher: output is switched off to protect device against over and under voltage.

  TimeSave™ function 

Reduced startup delay if unit was off for more than the standard delay period to 10 seconds. 

Unpacking & Inspection

After removing the polystyrene protective packaging from the SVS unit, inspect the ventilation slots to ensure that they are free from all obstruction. Use a vacuum 

cleaner to dislodge any obstructions.

Retain the box and packaging material to return the SVS unit in the unlikely event of its operational failure.

Installation

WARNING: This appliance must be earthed.  Ensure the rating of the load doesn’t exceed the capacity of the SVS. If in doubt consult your electrician.

If your mains outlet only has a 2-pin socket, consult a qualified electrician. If you are unfamiliar with installing electrical equipment consult a qualified electrician.

•  Although the unit does not produce excessive heat, ensure that it is positioned so that a free flow of air allows the unit to cool.

•  Do not install inside a closed cupboard and do not allow  papers or other materials to be piled on top.

Standard operation  

instructions

Please follow the procedure below to connect your SVS;

1  Turn your equipment OFF and unplug it from the wall socket.

2  Ensure that the switch on the SVS is OFF.

3  Plug the SVS into the wall socket or input  and plug your  

 

equipment into the SVS.

4  Turn the power ON at the wall socket.

5  Turn the SVS switch ON.

6  Turn your equipment ON.

7  The SVS model has a built-in AVS (Sollatek Automatic  

 

Voltage Switcher).  

This will ensure that that the load is not  

 

connected immediately. The delay will ensure that the mains 

 

is good before connecting the load and protects  

 

the equipment from rapid switching on and off. 

8  Once the wait period (see specifications) has passed, the  

 

SVS will relay power to your equipment.

9  The LEDs give you a visual indication of the input and  

 

output voltage.

10   If the mains voltage is 230V (ie normal) the green 0%  

 

Input voltage and green 0% Output voltage LEDs will  

 

both be lit. 

11  Any variation to the input power supply, up or down,  

 

will be monitored and adjusted by the SVS.

Operating Sequence

1.   Input voltage increase is displayed in steps of  

 

+5%, +10% and +15% and input voltage  

 

decrease is displayed in steps of -10%, -15% 

 

and -25%. 

 

The SVS indicates the plus or minus voltage  

 

variation by lighting the relevant LED.

2.   Within this range, the SVS will compensate by  

 

stepping up or stepping down the output voltage  

 

to maintain it’s norm of 230V + 6%, which will be  

 

indicated by the green 0% LED. 

3   If however the input voltage falls below -26%, the  

 

SVS will decrease the output voltage accordingly.  

 

The amount to which the voltage is lowered will be 

 

 indicated by the yellow -10% or red -20% LED.

4   Equally, if the input voltage rises above +18% (272V)  the SVS will increase the 

 

output voltage, indicated by the 10% or red +15% LED. 

5   In the models where the AVS functions is incorporated,  If the incoming voltage 

 

supply drops below the operating range of the SVS (144V or 72V for 110V unit)  

 

or above its operating (291V or 145V for 110V unit) it will shut down the output  

 

and protect your equipment against the severe incoming voltage. 

6   Power will be automatically reinstated to your appliance once the input voltage 

 

comes within the operating range of the SVS and the delay period has passed.

Troubleshooting

 

Guarantee

Sollatek (UK) Ltd guarantee that if within 2 years of purchase this appliance fails due to faulty workmanship or 

materials we will repair or replace it free of charge provided that:

•  The appliance has been correctly installed and used within the electrical range as specified on the  

  appliance nameplate.

•  The appliance has been used in accordance with the operating instructions.

•  There has been no attempt to open the unit for any reason whatsoever.

•  The unit is returned to Sollatek or Sollatek agent in good condition.

•  Sollatek shall not be liable under the terms of this guarantee for any material fault or damage as a result of  

  failure of this appliance.

•  This guarantee does not affect your statutory or Common Law rights.

Warranty & Returns

Should your SVS unit need repair, the quickest and simplest way is to return it to your dealer or to a Sollatek 

Service Centre or direct to the nearest Sollatek office.

IMPORTANT : Before returning a unit to a Sollatek Service Centre, contact the returns department to obtain a 

returns number. You will be asked for the following information which you should have ready;

Your name, address, telephone, fax (if available), email (If available)

Date purchased, where purchased

Serial number, model number 

Local voltage and type of load.

Description of fault

Once you have the returns number, ensure that the unit is securely packed enclosing a  short note with 

details as above and mark the unit clearly with the returns number. Remember also to add your name and 

address. 

Complying with the above will ensure that your unit will be treated promptly and efficiently. Without a 

returns number it will not be possible to trace a unit or check progress of repair of the unit.

All specifications are subject to change 

without prior notice.

230V

Input and output voltage response for standard models 

  

  

    

0-144  145 

155 

165 

175 

185 

195 

205 

210 

215 

225 

235 

240 

245 

255 

265 

275 

285 

290 

291

 

  

off 

182 

196 

208 

221 

233 

221 

232 

237 

215 

225 

235 

240 

218 

228 

237 

248 

255 

259 

off

inpuT 

ouTpuT 

115V

  

  

    

0-72 

73 

78 

83 

88 

93 

98 

103 

105 

108 

113 

118 

120 

123 

128 

133 

138 

143 

145 

146

 

  

off 

91 

98 

104 

111 

117 

111 

116 

119 

108 

113 

118 

120 

109 

114 

119 

124 

128 

130 

off

inpuT 

ouTpuT 

 

  Symptom 

Possible Cause 

Remedy

 

  The unit does not switch  

1) The fuse has blown. 

Change the fuse for a fuse of the correct rating.

  on. None of the LEDs are lit. 

2) The mains switch is not on. 

Ensure that the load currentdoes not exceed the  

 

   

3) No power is available  

capacity of the unit. If after changing the fuse the

   

on the input. 

unit is still not functioning return the unit for repair.   

   

 

Ensure that you are using the correct voltage (i.e.  

   

 

230V or 110V)

 

  The unit appears to be  

Load is not plugged in. 

1) Check that the load is plugged in.

  functioning normally but 

Load is not Switched on. 

2) Check that the input voltage is within the input 

  the load is not being  

Load fuse has blown. 

range of the SVS.

  switched on. 

 

3) Check that the load is switched on. 

   

Time delay is in progress 

4)  Wait for the delay to end.

  

  The unit appears to be  

The mains input is too low;

  functioning but the output  

1) Due to continuous brown-out

  voltage is persistently low. 

2) The unit is rated at 230V and 

 

   

the incoming supply is 110V

 

  The SVS continuously  

1) Possible internal fault.  

1) Ensure that the load current does not exceed the   

  performs self-test. If it 

 

rating of the SVS. 

  finds a fault the LEDs  

The fault could be temporary  

  will continously light from  

or permanent. 

  top to bottom repeatedly  

 

  in one of two patterns.  

2) Very bad mains waveform  

2) Turn the appliance off then switch SVS off. Restart the

   

or frequency. 

unit as per operating instructions.

    

 

    

 

3) If the above doesn't solve the problem please return 

   

 

the unit to a Sollatek service centre.

Name:                      

Front label SVS W/O UK INFO

Stock number:            

74527613

Date:    

 

Jan 2011

Voltright SVS04 Manual March 2013

A/I: 

S/C: 

0

I

Input

Output

0

I

0

I

0

I

Lin E Nin Lout E Nout

Inlet

On/off switch

Cable entry

Fuse (case type A only)

Rear panel

SVS04 A2 instruction sheet.indd   1

28/03/2013   10:01