background image

Model:

D-311

No.

437

Subject:

Battery does not charge up all the way: Add the
charge Kit

Date:

May 2, 1995

Symptom:

(**)

Battery is not able to operate unit for more than two hours even though battery was
fully charged (charged for more than 4 hours)

Solution:

Replace Resistor R424 in the Charge Detection circuit with the Charge Bd. Mount kit
and perform the following modification procedure.

REF

FORMER

NEW

DESCRIPTION

PART NUMBER

DESCRIPTION

PART NUMBER

R424

CHIP

RESISTOR 100

KOHMS

1-216-845-11

CHARGE BD A.

MOUNT KIT

X-4945-506-1

Procedure:

Set the variable resistor on the CHGA board counterclockwise, until the resistance
measured between the CHGA board’s leads is at a minimum (about 10K).

Remove R424 and solder the leads of the CHGA board in its place.

CSA-13

Hi-Fi Products

Service Bulletin

Sony Service Company - Technical Services
A Division of Sony Electronics Inc.
Sony Drive, Park Ridge, New Jersey  07656

Reference:  T/N #GA-94064

PRINTED IN USA

Autoflagged - NO

PRINTED ON RECYCLED PAPER

Reviews: