background image

Operating Instructions

10030S DIGITAL MULTIMETER

Multímetro Digital 10030S

SAFE

T Y RATE

D

CAT II

600V

UL61010-1

SAFE

T Y RATE

D

CAT III

300V

UL61010-1

µA

mA

20

200

10A

1.5V

9V

2000

2000

200

200

20

k

k

k

BATT.

mA

mA

HOLD

COM

10A

For

30sec.

MAX

every

15 min

FUSED

2000

200

600

OFF

600

200

20V

2000

200

mV

mV

!

!

Instrucciones de uso

12/14  Rev. 1
10030S manual

Contents Made in China

Product distributed by Southwire Company, LLC

One Southwire Drive, Carrollton, GA 30119

©2014 Southwire Company, LLC.  All rights reserved.

southwiretools.com

1-855-SW-T00LS

Toll Free Technical Help

Línea de Ayuda Técnica Gratuita

Scan for warranty information

and to access our mobile site.

Escanea para información de garantía

y acceso a nuestro sitio móvil. 

Summary of Contents for 10030S

Page 1: ...00 200 600 OFF 600 200 20V 2000 200 mV mV Instrucciones de uso 12 14 Rev 1 10030S manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 201...

Page 2: ...ot use the meter in wet or damp environments or during electrical storms Do not use the meter near explosive vapors dust or gasses Do not use the meter if it operates incorrectly Protection may be com...

Page 3: ...onent WARNING Operation is limited to CAT II applications when the insulated tips are removed from one or both test probes Refer to Input Limits section of this manual for maximum voltage ratings CAT...

Page 4: ...erve all safety precautions when working on live voltages WARNING 1 Set the rotary function switch to the 600V position 2 Insert the black test lead into the negative COM input jack and the red test l...

Page 5: ...serve all safety precautions when working on live circuits Do not measure current on circuits that exceed 250V Measurements in the 10A range should be limited to 30 seconds maximum every 15 minutes WA...

Page 6: ...ttery Test 1 Set the rotary function switch to the 1 5V or 9V BATT position 2 Insert the black test into the negative COM input jack and the red test lead into the positive V input jack 3 Touch the re...

Page 7: ...ts AC Voltage 200V 0 1V 600V 1V 1 2 reading 10 digits 50 60Hz 11 Operation Replacing the Fuses 1 Remove the two Phillips screws from the battery fuse door located on the back of the meter 2 Remove doo...

Page 8: ...product Whether Southwire repairs or replaces the product will be a determination that Southwire makes at its sole discretion SOUTHWIRE MAKES NO WARRANTY THAT THE PRODUCT WILL BE MERCHANTABLE OR FIT...

Page 9: ...ntalla LCD grande con luz de fondo Este metro est completamente compro bado y calibrado y bajo el uso apropiado proveer muchos a os de ZLY PJPV JVU HISL ADVERTENCIAS 3LH LU PLUKH ZPNH VKHZ SHZ 9LNSHZ...

Page 10: ...lasificaci n es la M S BAJA de cualquier componente individual ADVERTENCIA El funcionamiento est limitado a aplicaciones de CAT II cuando las puntas aisladas son retiradas de una o ambas sondas de pru...

Page 11: ...VERTENCIA 1 Mueva el interruptor rotario de funci n a la posici n de 600V 2 Inserte la sonda negra en la toma de entrada negativa COM y la sonda roja en la toma de entrada positiva V 3 Toque la punta...

Page 12: ...punto decimal apropiado y el valor Si la polaridad est invertida la pantalla indicar el signo de menos delante del valor Cumpla con todas las precauciones de seguridad al trabajar con circuitos activ...

Page 13: ...r una Bater a 1 Mueva el interruptor rotario de funci n a la posici n de 1 5V o 9V dependiendo del tipo de bater a 2 Inserte la sonda negra en la toma de entrada negativa COM y la sonda roja en la tom...

Page 14: ...0 1V 600V 1V 1 2 lectura 10 d gitos 50 60Hz 11 Cambio del Fusible 1 Retire dos tornillos Phillips de la cubierta de la bater a fusible 2 Retire la cubierta 3 Hale suavemente el fusible para retirarlo...

Page 15: ...DO PARA ALG N PROP SITO EN PARTICULAR SOUTHWIRE NO HACE NINGUNA OTRA GARANT A EXPRESA O IMPL CITA SALVO QUE LA GARANT A ESPEC FICAMENTE MENCIONADA EN ESTE P RRAFO SOUTHWIRE NO SER RESPONSABLE DE DA OS...

Reviews: