background image

INSTALLATION & SERVICE INSTRUCTIONS 

MANUAL FOR SOLAR PV MODULE 

www.sovasolar.com 

                                                                                  

READ THIS MANUAL BEFORE USING SOVA SOLAR PRODUCTS. 

                                           FAILURE TO FOLLOW THE MANUAL MAY RESULT IN SERIOUS    INJURY/DAMAGE. 

                                                                                                                                    

“Preserve the manual for long use” 

DISCLAIMER OF LIABILITY

 

This manual describes the installation, operation and maintenance of the solar photovoltaic module.  
The installation, handling and use of Sova Solar crystalline modules are beyond company control. Sova Solar 

does not assume any responsibility for loss, damage, injury or expense resulting from the improper 

installation, handling, use or maintenance.  
 Sova Solar assumes no responsibility for any infringement of patents or other rights of third parties that 

may result from use of the module. No license is granted by implication or under any patent or patent rights.  
 Specifications included in this manual are subject to change without prior notice

.  

SAFETY 

 

Follow the general and national safety and accident prevention regulations. 

 

Instructions relating to the functional safety of the system are in bold type. 

 

Do not connect any defective or damaged equipment (including measurement equipment) to PV 

modules. 

 

Follow the charging instructions of the battery manufacturer. 

 

Check the charging process regularly as described by the charger manufacturer. 

 

Never alter or remove the factory plates and identification labels. 

 

Keep children away from PV systems. 

 

Do not use water to extinguish fires of an electrical origin.  

 

 

Do not walk on the modules

 

The  warnings,  precautions  and  instruction  discussed  in  this  manual  cannot  cover  all  possible 
conditions  and  situations  that  may  occur.  The  module  should  be  used  with  common  sense  and 

caution by the end user. 

INSTALLATION WARNING 

DANGER OF EXPLOSION FROM SPARKING! DANGER OF ELECTRIC SHOCK! 

Solar modules generate electricity under incident light. The open circuit high voltage is present, even when 

the incident light levels are low. So it is recommended that the connection to the charge controller, load and 

battery may only be connected by trained personnel and i accordance with the applicable regulations. 

 

Summary of Contents for SS26060MC

Page 1: ...nd accident prevention regulations Instructions relating to the functional safety of the system are in bold type Do not connect any defective or damaged equipment including measurement equipment to PV modules Follow the charging instructions of the battery manufacturer Check the charging process regularly as described by the charger manufacturer Never alter or remove the factory plates and identif...

Page 2: ...as no hidden obstacles At a voltage of 75 V particularly with regard to module open circuit voltage over the entire temperature range the entire solar energy system must be installed with protection class Il as per IEC 61730 Select appropriate charge controller and battery for the solar module Secure all connections using terminals or solder all wire splices to ensure good connection Ensure that a...

Page 3: ...rs Do not place modules directly on top of each other CLIMATE CONDITION Install the SOVA SOLAR Photovoltaic modules in the following conditions Operating temperature 40 C to 85 C Storage temperature 40 C to 50 C Humidity below 85RH Wind pressure below 2400Pa speed 130km h for 1hr Snow Load Pressure below 5400Pa Corrosion resistance except for corrosive salt area and sulfurous area MOUNTING Before ...

Page 4: ... weight of the solar module and wind load Mounting system consists of corrosion proof bolts and nuts through the mounting holes in the mounting frame Mounting holes details for all modules are given in table below Model Range Polycrystalline Model Range MONO PERC Module Dimension mm Mounting hole Oblong mm Vertical mm Horizontal mm SS29572MC SS35572MC SS33072MP SS40072MP 1961 x 991 x 40 8 x 10 978...

Page 5: ...en circuit voltage of each module Refer to the Data Sheet Tα Voc Thermal coefficient of open circuit voltage for the module in Percentage refer to Sova Solar Spec sheet Tmin Minimum ambient temperature of the location of the plant GROUNDING Module frames should be connected to an earth ground for safety and protection from lightning The array frame shall be grounded in accordance with NEC Article ...

Page 6: ...per installation may create hazards in the event of a fire Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at Standard Test Conditions Accordingly the values of Isc and Voc marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor capacities fuse sizes a...

Page 7: ...gs in parallel Bypass Diode qty in Junction Box 3nos Model no GF3045 TYPE OF PRODUCT APPLICATION The modules are qualified for application class A Hazardous voltage IEC61730 higher than 50V DC EN61730 higher than 120V hazardous power applications higher than 240W where general contract access is anticipated Modules qualified for safety through EN IEC61730 1 and EN IEC61730 2 within this applicatio...

Page 8: ...76 15 44 20 21 3 SS29572MC 1500 44 77 36 05 8 67 8 19 295 76 15 18 20 21 3 66 cells SS34066MC 1500 43 76 34 85 9 95 9 76 340 78 19 04 20 19 6 SS33566MC 1500 43 43 34 74 9 90 9 65 335 78 18 76 20 19 6 SS33066MC 1500 43 22 34 47 9 79 9 58 330 78 18 48 20 19 6 SS32566MC 1500 42 99 34 37 9 68 9 46 325 78 18 20 20 19 6 SS32066MC 1500 42 77 34 27 9 57 9 34 320 78 17 92 20 19 6 SS31566MC 1500 42 64 34 19...

Page 9: ...SS25048MC 1500 31 82 25 60 9 97 9 78 250 79 19 02 20 14 6 SS24548MC 1500 31 58 25 37 9 94 9 66 245 78 18 64 20 14 6 SS24048MC 1500 31 43 25 07 9 84 9 58 240 78 18 26 20 14 6 SS23548MC 1500 31 26 24 92 9 63 9 44 235 78 17 88 20 14 6 SS23048MC 1500 31 10 24 80 9 57 9 29 230 77 17 50 20 14 6 SS22548MC 1500 31 01 24 65 9 54 9 13 225 76 17 12 20 14 6 SS22048MC 1500 30 91 24 51 9 35 8 98 220 76 16 74 20...