background image

AR-323-D

V200623

ACCESS & INDUSTRIAL CONTROL

    

    

   

CN1

CN2

- 1 -

1

5

6

2

3 4

11

7

8

9

10

11

12

13

Smart Digital Door Lock

RF Card

Contents

2

Template Sticker

Installation

Wiring

1

Products

Front panel 

Back panel 

(1) Mortise

(2) Cylinder

(3) Handle

(4) Strike

3

Accesories

Cable

Cable

Cable

CN1

CN2

CN3

Connector of Reader

Connector of Mortise

RS485

Power

Cable

1

2

3

4

Color

Thick Green

Thick Blue

Thick Black

Thick Red

Description

RS-485(B-)

RS-485(A+)

Power DC0V

Power

 

DC12V

Wire Application

Door Handle Direction

RH  (Right Push)

LH (Left Push)

RHR (Right Pull)

Before installation please check which door hand you require. 

LHR (Left Pull)

Door Handle & Mortise Lock Sticker

Strike Sticker

1.   Mortise                   

2.   Mortise Plate (mounted)

3.   Spindle of Knob     

4.   Spindle of Handle x2

11. Screw x2

5.Cylinder Lock

6.Mechanical Key x2

7.Waterproof Strap x2

8.Handle Screw x2

9.Elastic Spring x2

10.Allen Wrench

11. Screw x2

12. Strike Box

13  Strike Plate

Back Panel

Front Panel

Mortise

CN2

CN3

FCC ID:2ACLEAR

CN2

CN1

CN3

CN2

1

2

3

4

5

1

2

3

4

5

6

6

7

8

1

2

3

4

1

2

3

4

5

6

7

8

12V

GND

POWER

12VDC

A+

B-

Converter

AR-321-CM

Summary of Contents for AR-323D

Page 1: ...ower DC0V Power DC12V Wire Application Door Handle Direction RH Right Push LH Left Push RHR Right Pull Before installation please check which door hand you require LHR Left Pull Door Handle Mortise Lock Sticker Strike Sticker 1 Mortise 2 Mortise Plate mounted 3 Spindle of Knob 4 Spindle of Handle x2 11 Screw x2 5 Cylinder Lock 6 Mechanical Key x2 7 Waterproof Strap x2 8 Handle Screw x2 9 Elastic S...

Page 2: ... make cuts depending on hole stickers dimension Remove 2 Mortise Plate from 1 Mortise lock body Note 1 Only make deadbolt knob hole from inner door to mortise don t cross to outer door 2 Make sure accurate position right hole direction of striker plate before making cuts latch bolt position can be made firstly 3 Networking mode Additional hinge cuts is required for PC connection Separate 2 Mortise...

Page 3: ...dy and wired on site 4 5 6 Important 1 The depth of the 5 Cylinder Lock installation has already fixed The screw position must meet with the hollow part of the 5 Cylinder Lock 2 We suggest making sure that the upper bolt and the lower bolt functions correctly before fixing the screw Testing can be made using the mechanical key by rotating it to left and right and it will move bolt position means i...

Page 4: ...tion and the flat surface is facing out Provided 7 Waterproof Strap is recommended to apply for waterproof function and to preserve the lock durability from door opening and closing Front panel Connect 1 Mortise to Front Panel 10 STEP 1 Connect the Front Panel CN3 Connector of Mortise to 1 Mortise STEP 2 Bring CN2 Connector of Reader into Cable Hole to be connected to Back Panel later STEP 3 Plug ...

Page 5: ...l cover STEP 1 STEP 2 Back panel CN1 X CN2 Y 1 Connect 1 Mortise to Back Panel 13 STEP 1 Connect the CN1 Power and Communication Cable to DC power and RS485 communication refer to the Wiring Section STEP 2 Continuation from Step 10 2 connect the cable from Cable Hole to CN2 Connector of Reader of the Back Panel STEP 3 Fasten 3 Spindle of Knob from Deadbolt Knob Hole of 1 Mortise into Deadbolt Knob...

Page 6: ... Front Panel Back Panel and Front Panel position is in correct position 1 Peel off Strike Sticker and paste into the desired spot for installation 2 Start making the hole drilling based on the hole dimension on the sticker 3 Remove the sticker after hole drilling is finished STEP 1 Embed the Strike Box into the hole STEP 2 Embed the Strike Plate on Strike Box and fasten with Screws STEP 3 Installa...

Page 7: ...ant to modify refer to password setting 17 Add Tags Input 123456 or Master Code 11 SSSSS EEEEE OK e g Add User Address 00100 01254 Enter program mode 11 00100 01254 OK Add tag by presenting Delete tag by presenting Input 123456 or Master Code 22 1 Present the tag to Access Controller OK Input 123456 or Master Code 22 0 Present the tag to Access Controller OK Delete All Tags Input 123456 or Master ...

Page 8: ...y and Friday 08 1 09301620 01010100 Done M4 M8 Private PIN Card or PIN Enter program mode 12 UUUUU PPPP e g User Address 00001 and pass code 1234 input 12 00001 1234 Card and PIN Enter program mode 13 UUUUU PPPP e g User Address 00001 and pass code 1234 input 13 00001 1234 M6 Public PIN Card or PIN Enter program mode 15 PPPP Input 4 digit PIN default value 4321 PPPP 0000 cancel the function of sim...

Page 9: ...suddenly off then on Function Default Value M4 M6 M8 24 DDD Function Selection Value Application Default Value Auto Open without Presenting in Auto open Time Zone Alarm Output Lift Control Stop Alarm by pressing RTE Button or Closing the Door Doorbell 0 Disable 0 Alarm Output 0 None 0 Disable Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 064 128 1 ...

Page 10: ...e buffer time before entering arming mode 001 600 1 600 sec TTT the buffer time before the alarm is activated 001 600 1 600 sec SSSSS EEEEE 00000 01023 00000 03000 for AR 725H SSSSS Starting User Address EEEEE Ending User Address N 0 1st time zone 1 2nd time zone HHMM Starting time hhmm ending time i e 08301600 08 30 to 16 00 7123456H 7 days of week Sun Mon Tue Wed Thu Fri Sat Holiday H 0 disable ...

Page 11: ...Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone Networking Standalone 001 002 003 004 016 032 064 128 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 1 Activate 2 1 323DMaster Test MASTER CARD Setting Use the MASTER CARD software Input the MASTER CARD number and press Write Cut off and tranmit the power Acti...

Reviews: