background image

Installation Guide 

and Users Manual

Wall Mount Range Hood

IMPORTANT:

Read and save these instructions.

NOTICE:

Installer:

 Leave this guide with the homeowner

Homeowner:

 Keep this guide for future reference

PSD/F/L/Z

Rev. 3046u.5a

 

SPAGNA VETRO

Summary of Contents for PSD

Page 1: ...e and Users Manual Wall Mount Range Hood IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference PSD F L Z Rev 3046u 5a SPAGNA VETRO ...

Page 2: ......

Page 3: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Page 4: ...go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being...

Page 5: ... heights clearance 5 6 Calculating vent system length 6 Venting methods ductless conversion 7 Charcoal filters electrical requirements 8 Preparation 9 Installation 10 11 Range hood operations 12 13 Wiring diagram measurements 14 16 USE AND CARE Troubleshooting 17 Use and care information 18 Specifications 18 MAINTENANCE Cleaning 19 Replacing filter light bulb 19 20 WARRANTY Coverage exceptions 21 ...

Page 6: ...llation Guide and Users Manual 1 Set 5mm x 16mm Screw with Washer 4 Set 4mm x 16mm Tapping Screw 6 Pcs 4mm x 10mm Tapping Screw 16 Pcs Optional Toggle Bolt with Tapping Screw for Air Diverter 2 Set Optional Screw for Charcoal Filter 3 Pcs Lower standard chimney Upper standard chimney Flappers Parts supplied Range Hood vary with model Stainless Steel Baffle Filter s Chimney Mounting Bracket Grease ...

Page 7: ... coun 2 tertop stove recommend 28 to 31 Distance between the countertop stove 3 to the range hood Height of hood and duct cover 4 For the most efficient quiet operation A distance of 28 to 31 is recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 15 2 cm or bigger round metal aluminum vent work The size of...

Page 8: ...e no higher than 31 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to differen...

Page 9: ...version is intended for applications where an exhaust duct work is not possible to be installed When converted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust from cooking is drawn and filtered by a set of charcoal filters The air is then purified and re circulated back within the home We recommend to ALWAYS exhaust air outside of the home by employing existing...

Page 10: ...opper wire plug only Always use plug provided If not possible connect three wires ac cording to its color black to hot white to neutral and green to ground to house wires and cap with wire connectors Wire sizes copper wire only and connections must conform with the rating of the appliance as specified on the model serial rating label Wire sizes must conform to the requirements of the National Elec...

Page 11: ...nstalled Make sure there is proper clear ance within the ceiling or wall for exhaust vent Due to the weight and size of this unit please make sure that 2 the support system or framework being used is stable and secure in the ceiling Put a thick protective covering over counter top cook top or 3 range to protect from damage or dirt Remove any hazardous objects around the area when installing Mark t...

Page 12: ...into place Tighten screws to secure hood to the wall CAUTION Make certain the range hood is secure before releasing Connect the venting duct between the hood and the exhaust opening either on the ceiling or wall Use silver 4 tape or duct tape to make all joints secure and air tight Connect the range hood to a designated standard outlet please refer the product label for the suitable voltage 5 of t...

Page 13: ... Figure 7 9 To install stainless steel baffle filters refer to Figure 8 for the following five steps 10 Angle baffle filter toward back of hood Push baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting positions Repeat Step 12 to install all stainless steel baffle filters 11 Turn power ON in control panel C...

Page 14: ...lower motor running time starts to accumulate when it first rotates when the running time reached 30 hours the Cleaning Reminder Indicator C flashes and reminds user to clean the range hood After cleaning the filter and when the motor is not in use press and hold Increase Value button over 3 seconds to reset the timer Please note that turning off the system will not reset the Power On Elapsed Time...

Page 15: ...Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim the lights from high to low Level of brightness will be stored in system s memory CAUTION DO NOT touch the lights until switched OFFand cooled Note Light settings are independent from other settings including power of...

Page 16: ...Page 14 Wiring Diagram 4 Speed Wiring Diagrams Wiring Diagram 6 Speed NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights ...

Page 17: ...t exhaust Re circulating kit not shown Duct work and electric wiring region Note Type A anchors are designed for dry wall Not to be used with any other types of walls Mounting Bracket A B C A B C Hex Key Qty 1 PCS Optional with glass canopy Glass Canopy Screw Qty 4 PCS Optional with glass canopy Qty 6 PCS For sheet rock only A Qty 6 PCS B Qty 4 to 8 PCS Vary with model C Air Movement Direction ...

Page 18: ...Page 16 Measurements and Diagrams Continued All inch measurements are converted from millimeters thus inch measurements are estimated PSL Overall PSZ PSF PSD ...

Page 19: ...ir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping damage Please contact us im mediately The hood is not venting out properly 5 Make sure the distance between...

Page 20: ...components operating blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep frye...

Page 21: ...wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Aluminum Grease Filter Stainless Steel Fi...

Page 22: ...is unplugged or turn OFF breaker Make sure the lights are cool to touch carefully align the arrow on the inner ring with the arrow on the outer ring where it says OPEN with the Inner Ring Opener as shown in Figure 1 Figure 1 The inner ring will loosen and the light bulb will be available for removal as shown in Figure 2 Figure 2 Install a new light bulb and reverse the steps Turn ON breaker and ra...

Page 23: ...nsumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is no...

Page 24: ...ing fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty will carry...

Page 25: ...Page 23 Your Notes ...

Page 26: ...Page 24 Your Notes ...

Page 27: ...Page 25 Your Notes ...

Page 28: ...Spagna Vetro Appliances Inc Burnaby BC Canada www KitchenHoods ca tel 604 430 5252 SPAGNA VETRO ...

Reviews: