Installation and Operating Manual

Nova E H

2

O

Summary of Contents for NOVA E H2O

Page 1: ...Installation and Operating Manual Nova E H2O ...

Page 2: ...customers emo tions and speak to feelings such as security and comfort In order to be suc cessful we recommend that you read these installation instructions carefully in order to quickly become thoroughly familiar with the product In addition to information on how to install the product these instructions also contain important operating notes regarding fireplace insert safety and maintenance and ...

Page 3: ...f rotating disc air adjustment lever servomotor for S Thermatik 15 2 13 Changing the door stop 16 2 14 Combustion chamber lining 17 3 Initial commissioning 18 4 Operation 18 5 Cleaning and maintenance 19 5 1 Cleaning the heat exchanger 20 5 2 Cleaning the double glazing 20 5 3 Maintenance of the heat exchanger 21 6 Advisor 21 7 General warranty terms and conditions 22 7 1 Scope of Application 22 7...

Page 4: ...TRUCTIONS Prior to setup and installation of the tiled stove system Nova E H2 O a discussion must be conducted with your responsible district master chimney sweep He will advise you of building law regulations the suitability of your chimney and will execute the acceptance procedure of your tiled stove The chimney calculation is executed in accordance with DIN EN 13384 with the value triplet speci...

Page 5: ...itions materials and design An estimate can be made using 50 80 K m draught length This means that 520 C 200 C 320 K 60 K 5 m 1 The thermal discharge safety device integrated in the heating system will open the cold water inlet at a boiler temperature of approx 95 C The specified values represent the mean value over a combustion These values occur under test conditions if in 70 min a quantity of a...

Page 6: ...GB 6 Fig 1a Nova E H2 O with wall penetrating element Fig 1b Nova E H2 O with frame for front panels ...

Page 7: ... EN 13229 If a closed heating chamber should be created the thermal insulation material thicknesses must be increased in the verification procedure Type A mm B mm C mm D mm E mm F mm 1 0 570 1130 15 448 177 454 1 1 570 1130 15 448 177 454 1 2 570 1130 15 448 177 454 2 0 570 1130 15 448 177 454 Fig 1d Nova E H2 O with heat recovery section position diagram ...

Page 8: ...ont side vent plug 2 1 BASIC REQUIREMENT IMPOSED ON SETUP The Nova E H2 O tiled stove must only be mounted in thermostatically safeguarded systems in accordance with DIN 4751 or DIN EN 12828 All connections to the heating network must always be designed so that they can be detached e g as threaded union Only use temperature resistant pipelines within the fireplace cladding When using sealing mater...

Page 9: ...ater For the pipe connections we recommend the use of straight or angled radiator threaded unions DIN DIN EN state construction ordinances firing ordinances etc must be complied with and applied HeizAnlV Heating Systems Ordinance FeuVo Firing Installation Ordinance of the respective German Federal State 1 BlmschV First Ordinance on the Implementation of the Federal Immission Control Act EnEV Energ...

Page 10: ...safety device and pump thermostat E Flow connection 1 internal thread F Discharge for safety heat exchanger G Return connection 1 internal thread H Inlet for safety heat exchanger I Separate combustion air duct Ø150 J Emptying connection internal thread K Connection possibility for the heat recovery section Fig 2a Fig 2b ...

Page 11: ...insert with metallic coasting temperature box in the cladding or in the heating chamber must be designed as follows Hot air 990 cm at the upper points in the cladding Cold air 990 cm at the lower points in the cladding Minimum cross sections if connecting lines are shorter than 1 0 m and flue gas connection on the upper flue gas connection Hot air 450 cm2 Cold air 370 cm2 In addition the Regulatio...

Page 12: ...e the fitting for example At the cold water inlet a flow pressure of at least 2 0 bar must be available This pressure must be constantly ensured The possibility of water network fluctuations must be excluded For example this means that a mains voltage dependent domestic water supply is not approved A separate safety valve must also be installed if such a safety valve is installed at a different po...

Page 13: ...ion pump only starts up at a sufficient water temperature and switches off if the specified temperature is undershot A Electrical connection of the thermostat pump controller B Thermostat as pump controller e g Afriso with approx 3 0 m connecting line 2 x 0 75 mm2 C Return flow boost circulation pump D Terminal 1 not necessary E Phase L brown line F Switched phase L blue line Fig 3a Fig 3b The bro...

Page 14: ... buffer tank and the safety components such as safety valve and expansion tank is the responsibility of the planning firm and or of the executing installation company Bear in mind that during the combustion phase extremely high water throughput of approx 25 kW can briefly occur The heating installations must be configured accordingly among other things The following sample calculation can be helpf...

Page 15: ...er delivery it may be necessary to mount the rotating disc through the combustion chamber in the floor area of the tiled stove e g device design with S Thermatik Installation is not executed in the factory because the star adapter frictional connection between servomotor and rotating disc as well as the servomotor for the S Thermatik project downwards out of the device These components would be da...

Page 16: ...he door on the hinge side and pull it downwards and forwards 2 Replacement of locking pin c Use an open end wrench to dismount the locking pin d Mount the locking pin on the opposite side where a bore is provided 3 Insertion of the new door Insert the new door to do this slide the door with the upper pivot hinge into the provided bores Then open the door 90 and fit the lower pivot hinge hexagonal ...

Page 17: ...plate must be the rough top side and that the rear surface must have the appropriate pattern notches of the rear wall bricks The deflector plate must be pushed in until it is on the rear wall chamotte The baffle plate 10 must be inserted in the same manner see Fig 5c however it is positioned as shown in Fig 5d on the front of the device with a clearance of 15 30 mm 2 14 COMBUSTION CHAMBER LINING I...

Page 18: ...t only be executed after all necessary components are connected and all necessary safety devices are integrated and functional Before the stove fireplace insert is placed in service it must be filled and ventilated on the heating side heating network and water side thermal discharge safety device safety heat exchanger After the fill ing process check all hydraulic connections for leaks Operation w...

Page 19: ...issipation of the heat exchanger that is as uniform as possible and to avoid low chimney temperatures Double glazing IR reflective surface Through application of oxidic coatings on the glass surface infrared spectral components from the combustion chamber are reflected to a great extent These coatings generate the interference colours similar to a rainbow the so called IR reflective surface Throug...

Page 20: ...e damper is tilted slightly by the handle and taken out in a downwards direction Clean the thermal flue gas damper with a hand brush Then the turbulators bent pieces of sheet metal in the flue gas pipes are pulled downwards and out into the combustion chamber with pliers Subsequently the heat exchanger pipes and the middle channel as well as the outer surfaces of the heat exchanger must be cleaned...

Page 21: ...pump one level higher higher flow rate Circulation pump does not run Is the pump or power connection defective Return flow temperature too high 75 C Check whether the shut off elements are closed Is sufficient heating water available Ventilate Thermal discharge safety device drips Contamination of the discharge safety device Flush the thermal discharge safety device by activating the red button on...

Page 22: ...ireplace cassettes Basic body fireplace doors Spartherm Feuerungstechnik GmbH gives a 24 month warranty on elevating mechanisms operating devices such as handles adjustment levers shock absorbers electronic and electrical components such as exhausters gover nors original spare parts all purchased parts and safety devices Spartherm Feuerungstechnik GmbH gives a 6 month warranty on wearing parts aro...

Page 23: ...ing are observed In accordance with this warranty undertaking Spartherm Feuerungstechnik GmbH reserves the right either to rectify the defect or to replace the unit free of charge Remediation of defects shall take precedence This warranty undertaking expressly does not cover further compensation exceeding the statutory guarantee 7 7 EXTENSION OF WARRANTY In the case of performance in accordance wi...

Page 24: ...d for leaks yes no All safety devices thermal discharge safety device safety valve membrane expansion vessel checked yes no yes no Enter temperatures between insert and return flow boost Return flow temperature in C Flow temperature in C Visual inspection of the heating system yes no Function check executed yes no Fireplace operator has been instructed concerning operation and the Installation and...

Page 25: ...GB GB GB 25 NOTES ...

Page 26: ...GB 26 NOTES ...

Page 27: ...GB GB GB 27 ...

Page 28: ...t merk van wereldformaat voor uw woonkamer Światowa marka do Państwa salonu Торговая марка 1 для Вашего дома D Ihr Fachhändler UK Your specialist dealer F Votre revendeur spécialisé IT Il vostro rivenditore specializzato E Sus comercios especializados NL Uw vakhandelaar PL Państwa sprzedawca РУС Ваш дилер Spartherm Feuerungstechnik GmbH Maschweg 38 D 49324 Melle Phone 49 0 5422 94 41 0 Fax 49 0 54...