background image

INSTRUCTIONS FOR MODELS

92-SE-490-582-05

For additional assistance or service please contact:

SPEAKMAN

®

 Company

400 Anchor Mill Road
New Castle, DE 19720

800-537-2107

customerservice@speakman.com

www.speakman.com

SE-490
SE-495
SE-580
SE-582

TOOLS AND SUPPLIES

Level

Pencil

Drill

Adjustable

Wrench

Measuring

Tape

Socket

Wrench

MAINTENANCE

Please reference the parts listing for the correct repair 
part numbers. Only use genuine SPEAKMAN parts
when repairing or replacing components. To order
parts, call 1-800-537-2107. Be sure to turn off water 
supplies before beginning any maintenance.

3 year limited warranty.

Additional warranty information can be found at: 
www.speakman.com

WARRANTY

Be sure to wear proper eye protection.

SAFETY TIPS

IMPORTANT

ANSI Z358.1 states that weekly activation should be 
conducted on all plumbed emergency equipment to 
ensure that there is a suitable flushing fluid supply present 
and to clear the supply line of any sediment build-up that 
could prevent fluid from properly being delivered to the 
eye/eyeface wash device, as well as to minimize 
microbial contamination due to stagnant water. Also per 
the standard, the unit should be checked annually to 
ensure the unit still complies with the installation section 
(7.4) of the ANSI Z358.1 standard. ANSI Z358.1 
specifies that the height of the spray heads is to be 
between 33” - 45” from the floor. The SE-490/495/ 
580/582 unit shall be mounted ensuring the mounting 
surface (wall,etc.) and mounting hardware are sufficient 
to carry the load. Be sure to read instructions thoroughly 
before beginning installation. Do not overtighten any 
connections or damage may occur. SPEAKMAN furnishes 
a testing record tag (91-0635) with each unit. On this 
tag, the date of inspection and the inspector’s initials 
should be noted.

1

After selecting a suitable mounting location,
measure to ensure the spray head height is
between 33”- 45” from the floor. Mark and
drill holes according to hardware selection
specifications.

33"-45"

ABOVE FINISHED

FLOOR

(838-1143mm)

2

Using appropriate hardware (not included),
affix bowl to mounting surface. Ensure mounting 
hardware and structure are capable of 
supporting the product in use.Using a Level,
confirm the bowl is both level and plum.

3

Connect to an uninterruptable potable water 
supply with a minimum flowing pressure of 30psi 
and a maximum static pressure of 80psi to the 
1/2” NPT female water supply inlet.

1/2” NPT FEMALE INLET

4

Connect the drain trailpiece to an adequate
drain in accordance with local plumbing codes.

To Drain

5

To test, and for subsequent operation, push the 
Paddle Handle forward 90°. The unit will 
operate until the Paddle Handle is manually
pulled back to the OFF position.

SE-490 / SE-495 / SE-580 / SE-582 REPAIR PARTS

SPEAKMAN

®

SE-910

BRASS 1/2" BALL VALVE ASSEMBLY WITH PADDLE HANDLE

SE-910-SSBV

STAINLESS STEEL 1/2" BALL VALVE ASSEMBLY

RPG05-1177

AERATOR REPLACEMENT GROUP (6 EACH)

RPG21-0082-PC-P (NOT SHOWN) IN-LINE STRAINER REPAIR ASSEMBLY

RPG05-0715

SE-490 / SE-495 NON-AERATED EYE/FACE WASH BULLHORN ASSEMBLY

RPG38-0390

SE-490 / SE-495 NON-AERATED SPRAYHEAD ASSEMBLY

RPG05-0714

SE-580 / SE-582 AERATED EYE/FACE WASH BULLHORN ASSEMBLY

RPG38-0379

SE-580 / SE-582 AERATED SPRAYHEAD ASSEMBLY

RPG05-0943

BULLHORN WASHER GROUP

RPG07-0104

FLIP TOP DUST CAP REPLACEMENT (20 PER BAG)

ITEM NO.

PART NO.

DESCRIPTION

FLOW DATA:

PRESSURE

FLOW RATE

psi

bar

30

2.07

60

4.14

SE-580/582 FLOW DATA

gpm

L/min

3.2

12.1

3.4

12.9

PRESSURE

FLOW RATE

psi

bar

30

2.07

60

4.14

SE-490/495 FLOW DATA

gpm

L/min

4.5

17.0

4.6

17.4

Reviews: