background image

 

SPEC.732118.019 RE 

 

 

 

 

Agreed: 

 

FSUE “VNIIFTRI” 

 

OS VSI “VNIIFTRI” 

 

 

 

Operating Manual

 

Explosion-proof Infrared Projector  

Relion-TKV-300-N-IK 

Relion-TKV-300-A-IK 

Relion-TKV-300-M-IK 

 

 

 

 

 

 

 

  

 

 

2017

 

 

 

Summary of Contents for Relion-TKV-300-A-IK

Page 1: ...SPEC 732118 019 RE Agreed FSUE VNIIFTRI OS VSI VNIIFTRI Operating Manual Explosion proof Infrared Projector Relion TKV 300 N IK Relion TKV 300 A IK Relion TKV 300 M IK 2017 ...

Page 2: ...CTORS AFFECTING VISIBILITY 6 5 ASSEMBLY OF IR PROJECTOR 6 5 1 INSTALLATION OF IR PROJECTOR 6 5 2 PROJECTOR ASSEMBLY PROCEDURE 7 5 3 ELECTRICL INSTALLATION 8 6 TROUBLESHOOTING 9 7 TECHNICAL MAINTENANCE 9 8 REPAIR AND RETURN OF THE DEVICE 9 9 MANUFACTURER S WARRANTY 9 10 TRANSPORTATION AND STORAGE 10 11 ORDERING INFORMATION 10 ...

Page 3: ... GOST 30852 11 MEK 60079 12 and PUE sec 7 3 The projector body features IP68 class of protection from environmental effect The IR projector is operable within 500 C to 550 C temperature range 8 high power IR emitters with focusing lenses provide back light for distance up to 100m Basic configuration of the projector default option features the following parameters of radiation angle and illuminati...

Page 4: ...n angle and illumination range are provided optionally by separate order m radiation angle 100 100 radiation angle 900 15 Cover protection class IP 68 Radiating wave length nm 850 Switch on off threshold lx 3 Power voltage V 12 36 DC Consumed current A max 0 5 Power consumption W 6 Weight kg max TKV 300 M IK 4 8 TKV 300 N IK 5 4 TKV 300 A IK 2 7 Temperature range 0 C 50 55 Specified lifetime for t...

Page 5: ...from galvanized low carbon steel Switching board with terminal boxes used for power cable connection is located on the back cover of the IR projector from the inside Loop power supply for board with IR emitters is connected to the switching board Silica gel is placed into IR projector body for moisture absorption IR projectors Relion TKV 300 M IK and Relion TKV 300 N IK feature the same dimensions...

Page 6: ... in the present Operating Manual If connection diagrams differ from the recommended connection pattern and are not approved by the manufacturer the warranty period shall be terminated and this may result in IR projector failure Installation and connection of the IR projector shall be performed by authorized personnel only 5 1 INSTALLATION OF IR PROJECTOR IR projector shall be positioned in such ma...

Page 7: ...Determine operational location and fix the bracket of mounting and positioning device 9 fig 2 and 3 Undo retention screws of the projector back cover 3 Switching board is located on the inside of the back cover fig 5 Carefully take off the cover from the projector body so not to damage power supply loop of the board with IR emitters connected to the switching board Disconnect terminal of the power...

Page 8: ...l be used Cable cross sections are selected according to the power supply in the line and cable line length All outer mains are connected through inner terminal block which is an integral part of the IR projector For wires with sections from 0 08mm2 to 2 5mm2 pressing camps are used Terminal contacts of the switching board which are located inside terminal block of the IR projector are shown in Fi...

Page 9: ...tor 7 TECHNICAL MAINTENANCE Inspection window of the IR projector shall be maintained clean for this purpose cleaning shall be performed progressively as dirt accumulation takes place cleaning shall be performed with brush or wet flannel Technical maintenance intervals are determined by technical regulations approved by technical manager of organization 8 REPAIR AND RETURN OF THE DEVICE If any def...

Page 10: ...positioning device 1 pc fixing clamp for models TKV 300 M IK and TKV 300 N IK 1 pc Silica gel 1 pc label SPEC 732118 019 ET 1 pc passport SPEC 732118 019 PS 1 pc sun shield not included in the scope of supply supplied in separate order 1 pc cable gland not included in the scope of supply supplied in separate order 2 pcs At the time of order please specify 1 Model of IR projector TKV 300 N IK ex pr...

Page 11: ... 4 thread KV 15 N KV 15 M Cable gland for installation with cable in metal hose with internal diameter D 15mm KV 18 N KV 18 M Cable gland for installation with cable in metal hose with internal diameter D 18mm KV 20 N KV 20 M Cable gland for installation with cable in metal hose with internal diameter D 20mm SHT1 2 KV12 ZG SHT3 4 KV15 Fig 7 Cable gland kit Fig 8 Different input devices 1 body foun...

Page 12: ...12 MANUFACTURER S ADDRESS 2D Lenin St the Sverdlovsk Oblast 623700 Russia tel 343 379 07 95 info spectron ops ru www spectron ops ru ...

Reviews: