Page 1: ...100 Series Data Loggers PRODUCT MANUAL Model s 110 115 125 130 150 ...

Page 2: ...chnologies Inc at 800 248 8873 or 815 436 4440 between 7 30 am and 5 30 p m CST FAX at 815 436 4460 or E Mail at info specmeters com www specmeters com Spectrum Technologies Inc 12360 S Industrial Dr East Plainfield IL 60544 CONTENTS General Overview 3 Specifications 4 Installation and Placement 5 Connecting to the Computer 6 SpecWare Software 7 Battery Replacement 8 Trouble Shooting 9 Service and...

Page 3: ...ogger This WatchDog Data Logger series will allow you to record conditions at remote sites The WatchDog s blinking LED light confirms the logger is recording Download the accumulated data at your convenience using the powerful SpecWare software SpecWare will present the data in graphical and tabular form Use the software to calculate growing degree days and chill hours and or view daily monthly an...

Page 4: ... per interval Rainfall 125 Temp Internal 4 to 158 F 20 to 70 C External 22 to 212 F 30 to 100 C 1 F 0 6 C 7 000 measurement data points 3 500 per channel Temp 150 Temp RH 4 to 158 F 20 to 70 C 1 F 0 6 C 3 RH 7000 measurement data points 3 500 per channel None 130 Temp Temperature 4 to 158 F 20 to 70 C Leaf Wetness 0 to 15 1 F 0 6 C 7 000 measurement data points 3 500 per channel Leaf Wetness Speci...

Page 5: ...se it is required that the WatchDog logger be placed in a mini radiation shield to protect it from solar radiation and other sources of reflected heat The radiation shield also protects the logger from rain To place the WatchDog into the radiation shield unscrew the two finger nuts and remove the top of the radiation shield Important External sensor wires connect to the logger through an opening a...

Page 6: ...e computer is during the launching and downloading of the data logger After the logger has been launched and or downloaded disconnect the logger and place it in the environment you wish to monitor Computer Port If the computer will not connect with the logger you may need to change the battery or change the com port settings Refer to the battery replacement section on page 8 for battery instructio...

Page 7: ...terval choices offered are 1 10 15 30 60 and 120 minutes Use SpecWare software to read the logged data Once the data has been downloaded to the computer SpecWare software creates a plot and offers a wide variety of Report options Refer to the SpecWare Users Guide for more detailed instructions SpecWare Software ...

Page 8: ...k cover of the WatchDog 2 Remove the back cover 3 Slide the battery out of the battery holder 4 Insert a new CR2032 battery positive side up 5 Replace WatchDog cover 6 Tighten back cover screw The logger is ready to be relaunched if the LED briefly illuminates following battery installation After being relaunched with the SpecWare Software the LED light will resume blinking Insert a flat edged scr...

Page 9: ...ough SpecWare software Q Why is logger logging invalid or out of range readings A External temperature sensor is not plugged into the port Q Can I use the external port of my WatchDog Model 125 or 130 to monitor rainfall A The external port is only set up to be connected to a temperature sensor for the 125 or a leaf wetness sensor for the 130 Trouble Shooting ...

Page 10: ...trum Dealer When Contacting Spectrum Technologies Please indicate that you need Technical Support Be prepared to 1 Provide details on the hardware and software configuration of your components including manufacturer model number peripherals and versions of the operating system 2 Completely describe the problem The more information you provide the faster and more accurately we will be able to respo...

Page 11: ...This warranty does not cover damage due to improper installation or use lightning negligence accident or unauthorized modifications or to inci dental or consequential damages beyond the Spectrum prod uct Before returning a failed unit you must obtain a Returned Materials Authorization RMA from Spectrum Spectrum is not responsible for any package that is returned without a valid RMA number or for t...